AP7961

Rack PDU,Switched,Zero U,5.7kW,208V,(21)C13 & (3)C19

Remote reboot switched PDU

  • In-band and out-of-band capability
  • In-band via secure HTTPS web-browser, Telnet, or SSH
  • Out-of-band via RS-232
  • SNMP management

Metered switched PDU

APC Switched Rack PDU , Input: 208V 3PH , Input Connections: NEMA L21-20P , Cord Length: 3 feet ( 0.91 meters ) , Output: 208V , Output Connections: IEC 320 C13,IEC 320 C19

Includes: Installation guide, Rack Mounting brackets, Toolless Mounting Kit, User Manual

Specifications

Output

Nominal Output Voltage 208V
Maximum Total Current Draw per Phase 20A
Output Connections (21) IEC 320 C13 (3) IEC 320 C19
Always on Outlets 24
Overload Protection No

Input

Nominal Input Voltage 208V 3PH
Input Frequency 50/60 Hz
Regulatory Derated Input Current (North America) 16A
Input Connections NEMA L21-20P
Cord Length 3 feet (0.91 meters)
Number of Power Cords 1
Maximum Input Current per phase 20A
Load Capacity 5700 VA

Physical

Net Weight 13.00 lbs. (5.91 kg)
Maximum Height 63.75 inches (1619 mm)
Maximum Width 2.19 inches (56 mm)
Maximum Depth 1.73 inches (44 mm)
Shipping Weight 15.00 lbs. (6.82 kg)
Shipping Height 84.00 inches (2134 mm)
Shipping Width 6.00 inches (152 mm)
Shipping Depth 5.00 inches (127 mm)
Color Black

Environmental

Operating Environment 32 - 113 °F (0 - 45 °C)
Operating Relative Humidity 5%
Operating Elevation 0-10000 feet (0-3000 meters)
Storage Temperature -13 - 149 °F (-25 - 65 °C)
Storage Relative Humidity 5%
Storage Elevation 0-50000 feet (0-15000 meters)

Conformance

Regulatory Approvals cUL Listed,CSA,FCC Part 15 Class A,ICES-003,Industry Canada, METI Denan, UL 60950,UL Listed
Standard Warranty 2 years repair or replace
ROHS/WEEE Compliance RoHS 7b Exemption

AP7961 Features

Flash Upgradable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
High Power Density  
Multi-branch power input  
Multiple User Support  
Remote Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. (Note: Only applicable for units categorized as Networked).
Toolless mounting capability  
Vertical mounting capability  

Switched Rack PDU Features & Benefits

Network Management Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Remote Individual Outlet Control Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
Local Current Monitoring Display The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
Load indicator LED Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Flash Upgradable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Integrates with InfraStruXure Central An IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Rack-Mountable Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Wide range of input and output connections Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.


APC Home Bomara Homepage Request Information

Bomara Associates Phone: 800.5BOMARA (800.526.6272) Phone: 978.452.2299 Fax: 978.452.1169 3 Courthouse Lane, Chelmsford, MA 01824 USA
Phone: 800.5BOMARA (800.526.6272)

Phone: 978.452.2299

 

Fax: 978.452.1169

Email: bobr@bomara.com

  Web: www.bomara.com

3 Courthouse Lane, Chelmsford, MA 01824 USA
Serving the marketplace for over 40 years

© 2014 by Bomara. All rights reserved

 



First Name:
Last Name:
Company:
Address:
Mail Stop:
City:
State (if in US):
Province/Region (if outside US):
Country:
ZIP (Postal) Code:
E-mail:
Telephone:
Fax:
Questions/Comments:
Verification: Please type:
Please have a Bomara Associates representative contact me