| APC Symmetra LX 12kVA Scalable to 16kVA N+1 Rack-mount, 220/230/240V or 380/400/415V |
| APC Symmetra LX, 12000VA/8400W, Input 230V, 400V 3PH/Output 230V, Interface Port DB-9 RS-232, Smart-Slot, Extended runtime model, Rack Height 19 U |
| Includes: CD with software, Documentation CD, Installation Guide, User Manual, Web/SNMP Management Card |
Part Number : SYA12K16RMI
|
Runtime Chart |
Additional Information
Product Overview
|
|
|
| Technical Specifications |
Output
|
| Output power capacity |
12,000 VA |
| Output power capacity |
8,400 Watts |
| Max Configurable Power |
16,000 VA |
| Max Configurable Power |
11,200 Watts |
| Nominal output voltage |
230V |
| Output Voltage Note |
Configurable for 220 : 230 or 240 nominal output voltage |
| Output Voltage Distortion |
less than 5% at full load |
| Output Frequency (sync to mains) |
47-63Hz |
| Crest Factor |
up to 5 : 1 |
| Waveform type |
Sinewave |
| Output Connections |
| (1) Hard Wire 3-wire (H N + G) |
|
| (8) IEC 320 C13 |
|
| (10) IEC 320 C19 |
|
|
|
| |
Input
|
|
| |
Batteries & Runtime
|
| Battery type |
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof |
| Pre-Installed Batteries |
3 |
| Battery Slots Empty |
1 |
| Replacement battery cartridge |
SYBT5 |
| RBC™ Quantity |
3 |
Typical backup time
at half load |
20.2 minutes (4200 Watts) |
Typical backup time
at full load |
7.5 minutes (8400 Watts) |
| Runtime Chart |
Symmetra LX |
| Extended run options |
SYA12K16RMI 2 hrs 39 mins
SYA12K16RMI + (1)SYBT5 3 hrs 40 mins
SYA12K16RMI + (1)SYRMXR4B4I 5 hrs 31 mins
SYA12K16RMI + (2)SYRMXR4B4I 8 hrs 30 mins
SYA12K16RMI + (3)SYRMXR4B4I 11 hrs 35 mins
SYA12K16RMI + (4)SYRMXR4B4I 14 hrs 43 mins
SYA12K16RMI + (5)SYRMXR4B4I 17 hrs 56 mins
SYA12K16RMI + (6)SYRMXR4B4I 21 hrs 11 mins
SYA12K16RMI + (7)SYRMXR4B4I 24 hrs 28 mins |
|
| |
Communications & Management
|
| Interface port |
DB-9 RS-232, Smart-Slot |
| Available Smart Slot Interface Quantity |
1 |
| Pre-Installed SmartSlot Cards |
AP9619 |
| Control panel |
Multi-function LCD status and control console |
| Audible alarm |
Audible and visible alarms prioritized by severity |
| Emergency Power Off (EPO) |
Yes |
|
| |
Physical
|
| Maximum height |
33 inches ( 84 cm ) |
| Maximum width |
19 inches ( 47 cm ) |
| Maximum depth |
27 inches ( 69 cm ) |
| Rack Height |
19 U |
| Net weight |
534 lbs. ( 243 kg ) |
| Shipping Weight |
638 lbs. ( 290 kg ) |
| Shipping Height |
42 inches ( 105 cm ) |
| Shipping Width |
24 inches ( 60 cm ) |
| Shipping Depth |
39 inches ( 100 cm ) |
| Color |
Black, Silver |
| Units per Pallet |
1 |
|
| |
Environmental
|
| Operating Environment |
0 - 40 °C ( 32 - 104 °F ) |
| Operating Relative Humidity |
0 - 95 % |
| Operating Elevation |
0-10000 feet ( 0-3000 meters ) |
| Storage Temperature |
-15 - 45 °C ( 5 - 113 °F ) |
| Storage Relative Humidity |
0 - 95 % |
| Storage Elevation |
0-15000 feet ( 0-4500 meters ) |
| Online thermal dissipation |
3,707 BTU/hr |
|
| |
Conformance
|
|
| |
|
Options: Automatic Transfer Switches
Batteries
Battery Cables
External BackPlate Kits
Internal BackPlate Kits
Isolation Transformers
Management Devices
MasterSwitches/Outlet Strips
Power Cords
Power Modules
Service Bypass Panels
Services
Software
|
| |
| General Features: Audible Alarms
Automatic internal bypass
Automatic restart of loads after UPS shutdown
Automatic self-test
Battery modules connected in parallel
Cold-start capable
Configurable for N+1 internal redundancy
Disconnected battery notification
Field-replaceable power distribution panel
Frequency and voltage regulation
Generator Compatible
Hot-swappable batteries
Hot-swappable intelligence modules
Hot-swappable power modules
InfraStruXure Manager Compatible
Input Power Factor Correction
Intelligent Battery Management
LCD display
Manageable external batteries
Modular design
Network manageable
Plug-and-Play external batteries
Power conditioning
Power Modules connected in parallel
Predictive failure notification
Programmable Frequency
Rack/Tower Convertible
Redundant Intelligence Modules
Removable input/output wiring tray
Resettable circuit breakers
Safety-agency approved
Scalable Power Capacity
Scalable runtime
Shippable with modules installed
SmartSlot
User-replaceable batteries
User-replaceable intelligence modules
User-replaceable power modules
more details...
|
| Topology: Double Conversion Online |
|
|
|
|