| Description |
APC Back-UPS, 500VA/325W, Input
120V/ Output 120V, Interface Port USB |
 |
| General Features |
Addl Surge Protected Outlets,
Audible Alarms, Intelligent Battery Management,
Internet FAX - modem - DSL protection , Lightning
and Surge Protection, Replace Batt Indicator,
Resettable circuit breaker, Site wiring fault
indicator, Software, Transformer Block Spacing, USB
compatible, User Replaceable batteries |
 |
| Includes |
CD with software, User Manual, USB
cable, Velcro Cord Management Straps |
 |
 |
Technical Specifications
 |
|
| Output |
 |
| Output power capacity |
500 VA |
 |
| Output power capacity |
325 Watts |
 |
| Nominal output voltage |
120 V |
 |
| Waveform type |
Stepped approximation to a sinewave |
 |
| Output Connections |
| (3)NEMA 5-15R |
 |
| (3)NEMA 5-15R (Surge) |
|
|
 |
 |
| Input |
 |
| Nominal input voltage |
120 V |
 |
| Input frequency |
50/60 Hz +/- 3 Hz (auto sensing) |
 |
| Input Connection Type |
| NEMA 5-15P |
 |
|
 |
| Cord Length |
6 feet |
 |
Input voltage range
for main operations |
98 - 140 V |
 |
 |
| Batteries |
 |
Typical backup time
at half load |
20.0 minutes (162.5 Watts) |
 |
Typical backup time
at full load |
7.3 minutes (325 Watts) |
 |
| Battery type |
Maintenance-free sealed Lead-Acid battery with
suspended electrolyte : leakproof |
 |
| Typical recharge time ** |
12 hour(s) |
 |
| Replacement battery cartridge |
(1) UPS Battery
Replacement Form |
 |
| Liquid Electrolyte Value |
0.0 |
 |
 |
| Physical |
 |
| Maximum height dimensions |
2.70 inches ( 6.86 cm) |
 |
| Maximum width dimensions |
17.00 inches ( 43.18 cm) |
 |
| Maximum depth dimensions |
7.00 inches ( 17.78 cm) |
 |
| Net weight |
8.60 lbs ( 3.91 kg) |
 |
| Shipping Weight |
9.40 lbs ( 4.27 kg) |
 |
| Shipping Height |
3.20 inches ( 8.13 cm) |
 |
| Shipping Width |
21.20 inches ( 53.85 cm) |
 |
| Shipping Depth |
7.00 inches ( 17.78 cm) |
 |
| Color |
Charcoal |
 |
| Units per Pallet |
196.0 |
 |
 |
| Communications &
Management |
 |
| Interface port |
USB |
 |
| Management software included |
PowerChute USB Bundle |
 |
| Control panel |
LED status display with On Line : On Battery :
Replace Battery and Building Wiring Fault |
 |
| Audible alarm |
Alarm when on battery : distinctive low battery
alarm : overload continuous tone alarm |
 |
 |
| Surge
Protection and Filtering |
 |
| Surge energy rating |
445 joules |
 |
| Filtering |
Full time multi-pole noise filtering : 5% IEEE
surge let-through : zero clamping response time :
meets UL 1449 |
 |
| Dataline protection |
RJ-45 Modem/Fax protection (two wire single
line) |
 |
 |
| Environmental |
 |
| Operating Environment |
0 - 40 °C (32 - 104°F) |
 |
| Operating Relative Humidity |
0 - 95% |
 |
| Operating Elevation |
0-10000 feet (0-3000 m) |
 |
| Storage Temperature |
-15 - 45 °C (5 - 113°F) |
 |
| Storage Relative Humidity |
0 - 95% |
 |
| Storage Elevation |
0-50000 feet (0-15000 m) |
 |
| Audible noise at 1 meter from surface of
unit |
45 dBA |
 |
 |
| Conformance |
 |
| Approvals |
CSA, FCC Part 15 Class B, FCC Part 68, UL
1778 |
 |
| Standard warranty |
2 years repair or replace |
 |
| Equipment protection policy |
Lifetime : $75, 000 |
 |
|
** The time to recharge to 90% of full battery
capacity following a discharge to shutdown using
a load rated for 1/2 the full load rating of the
UPS.
|
 |