| User
Interface |
 |
| Compaq Insight Manager |
Access power
management directly from Compaq Insight Manager
main screen. |
 |
| PowerChute plus |
Full featured,
local UPS management |
 |
| Web-based Power Management |
Use Insight
Manager web-based interface to manage power. See
PC Web Device
Manager for more information. |
 |
 |
| UPS
Administration |
 |
| Task Scheduling |
Schedule
periodic server shutdown/restart, UPS self-test and
UPS runtime calibration |
 |
| UPS Operating Parameters |
Full control
over UPS transfer settings and sensitivity to power
fluctuations. |
 |
| UPS Audible Alarm |
Configure UPS
alarm to beep on power failure, power failure + 30
seconds, at low battery condition, or never
beep. |
 |
 |
| Diagnostics |
 |
| UPS Self-test |
Initiate self
test of local or remote UPS to maximize UPS
uptime |
 |
| UPS Runtime Calibration |
Initiate
runtime calibration of local and remote UPS to
maintain accurate runtime values. |
 |
| Predictive failure analysis |
The UPS
conducts regular internal self-tests. When a
potential problem is detected, like the need for a
replacement battery, a notification is sent to the
relevant administrators and users before the
problem arises. |
 |
| Data Log |
Quickly
pinpoint power problems by tracking power data such
as min/max utility line voltage, battery voltage,
line frequency, load capacity. Also tracks ambient
temperature and humidity (requires Measure-UPS
accessory). See Measure-UPS product
page for more information. |
 |
| Event Log |
Records
selected power events with a description and
time/date stamp to enable diagnosis of UPS/power
problems. |
 |
 |
| Event
Handling |
 |
| Insight Manager Event Response
integration |
Use Compaq
Event Response application to forward five major
power events (AC line failed, AC line okay, UPS
shutdown, UPS has low battery,
Overload) |
 |
| Over 35 Power Events |
For each power
or environmental event, choose as many as seven
different response actions (i.e. page, email, log
event, broadcast, run command file, and
shutdown). |
 |
| Paging |
Receive timely
pages for power and environmental
events |
 |
| Email |
Receive timely
email alerts for power and environmental events.
Supports MHS. |
 |
| Broadcast |
Receive timely
broadcasts for power and environmental
events |
 |
| Command File |
Run a command
file to shutdown applications before OS shutdown is
initiated |
 |
| SNMP Traps |
Power alerts
can be sent to Compaq Insight Manager alarm
log. |
 |
 |
| Shutdown/Reboot |
 |
| Operating System Shutdown |
Gracefully
shutdown operating system in the event of an
extended power failure |
 |
| Application Shutdown |
Gracefully
shuts down Lotus Notes. Create customized shutdown
scripts for any application using PowerChute
Command File option. |
 |
| Multi-server Shutdown |
Via network.
See PowerChute
network shutdown for more information.
Via serial cable. See Interface Expander
accessory for more information. |
 |
| Administrative Shutdown |
Immediate,
graceful shutdown/restart of servers |
 |
| Shutdown Parameters |
Set and modify
the shutdown parameters to best suit the needs of
the server being protected. Required operating
system shutdown time. |
 |
| Power Return Parameters |
Enable
automatic server reboot on return of AC Power.
Ensure batteries are sufficiently charged before
returning power to the server to quard against
successive power outages. |
 |
 |
| Recommended
Applications |
 |
| Compaq servers. |
 |
 |