| SPECIFICATIONS |
SU700X93 |
SU2200X93 |
SU3000RMX93 |
| Communications interface |
x |
x |
x |
| AVR Boost |
x |
x |
x |
| AVR Trim |
x |
x |
x |
| QuickSwap |
x |
x |
x |
| UPS-Link Control Language |
x |
x |
x |
| Replace Battery Indicator |
x |
x |
x |
| Load Power and Voltage Meters |
x |
x |
x |
| Low Battery Indicator and Overload Indicator |
x |
x |
x |
| Software Configurable |
x |
x |
x |
| Test Switch |
x |
x |
x |
| SNMP Support Available |
x |
x |
x |
| Warranty |
2 years, with Lifetime Equipment Protection |
| Approvals |
UL listed, CSA certified, FCC Class B compliance,
Novell Labs approved |
| Input line |
6 ft. attached |
| Output receptacles (NEMA 5-15R) |
4 |
8 |
6 |
| Maximum Dimensions (HxWxD) |
6.2x5.4x14.1" |
17.0x7.7x21.5" |
| Net Weight |
29 lbs. |
112 lbs |
126 lbs |
| Shipping Weight |
32 lbs |
132 lbs |
145 lbs |
| OPERATION |
SU700X93 |
SU2200X93 |
SU3000RMX93 |
| Nominal Input voltage |
120 Vac, single phase; 50 or 60 Hz (auto-selectable) |
| Transfer time (typical/max) |
2/4 milliseconds, includes detection time |
| On-Battery Output voltage |
Pure sine wave output at 115 Vac +/-5%,
-10% after low battery warning, synchronized to utility line |
| Smart Boost and Smart Trim Operation |
On-Line operation for input between 90
to 145 Vac. Output will be 103 to 132 VAC.
AVR Boost increases voltage 12% if input is 90 to 103 Vac. AVR Trim
reduces voltage 12% below input if 145 to 132 Vac. |
| Double Pole Circuit breaker/Double Pole Switch |
Safety reasons dictate that the "Delta
Power" shipboard Smart-UPS have a double pole circuit breaker and
a double pole switch since both legs carry power. |
| Capacity (Volt-Amps, Watts) |
700,450 |
2200, 1600 |
3000, 2250 |
| Load power factor range, crest factor range |
0.5 to 1.0, <5 |
| Surge energy rating, peak current capability |
320 Joules, 26kA |
480 Joules, 39kA |
| Normal, common mode clamping response time |
0 ns, <5 ns typical |
| Normal mode surge voltage let through when subjected to IEEE 587
Cat. A 6kV test |
<0.7% of peak typical |
<0.3% of peak typical |
| Normal/common mode noise suppression at 1.0MHz, 3.0MHz, 10.0MHz |
68/50, 57/50, 50/27 dB |
63/74, 54/48, 47/35 dB |
58/60, 52/52, 54/28 |
| Sealed, maintenance-free lead acid batteries with 3-6 year typical
lifetime |
Two 12V, 6.5AH |
Four 12V, 17AH |
Eight 12V, 7AH |
| Recharge time to 90% capacity after discharge into 50% load |
1 to 2 hours |
| Ambient operation |
10,000 ft. (3,000 meters) max. elevation,
0-95% humidity non-condensing, 32-113 deg F (0-40 deg C) |
| Storage elevation |
50,000 ft. (15,000 meters) max. 5-113 deg
F (-15 - 45 deg C) |
| Max audible noise at 3 ft. from surface of unit |
<41 dBA |
<50 dBA |
| On line eff. |
94% |