APC Symmetra RM 2kVA Scalable to
6kVA N+1 200V
Part Number : SYH2K6RMJ
Product Distribution : Japan
|
|
|
|
|
 |
| Description |
APC Symmetra, 2000VA/1400W, Input 200V/ Output 200V,
Interface Port DB-9 RS-232, RJ-45 10 Base-T Ethernet for web/
SNM, Rack Height 8 U |
 |
| General Features |
Alarms, Audible Alarms, Automatic Voltage Regulation (AVR)
, Brownout correction, Built-in automatic bypass, Built-in manual
bypass, Built-in SmartSlot, Built-in Web/SNMP management, EPO
, Event logging, Extendable Run Time, Fan Surveillance, Hot
Swap Batteries, Hot Swap Electronics, Input Power Factor Correction
, Intelligent Battery Management, LCD AlphaNumeric Display,
Lightning and Surge Protection, Load Meter, Multiple System
Shutdown, Overload Indicator, Pager notification, Power expansion
capability, Rack Mount, Sine-wave output, Software, Status
Indicator LED's, Unattended Shutdown, Web Management |
 |
| Includes |
Installation Manual in Japanese, Rack Mounting Brackets,
Rack Mounting support rails, User Guide in Japanese, User Manual
, Web/SNMP Management Card |
 |
 |
|
|
 |
| Output
|
 |
| Output power capacity |
6,000 VA |
 |
| Output power capacity |
4,200 Watts |
 |
| Max Configurable Power |
6,000 VA |
 |
| Max Configurable Power |
4,200 Watts |
 |
| Nominal output voltage |
100, 200 V |
 |
| Waveform type |
Sinewave |
 |
| Output Connections |
| (12)NEMA
5-15R |
|
| (2)NEMA
L6-20R |
|
|
 |
 |
| Efficiency at full load |
85 % |
 |
| Bypass |
Internal Bypass (Automatic and Manual) |
 |
| Output Voltage Distortion |
<5% |
 |
| Output Frequency (sync to mains) |
57-63Hz for 60Hz nominal, 47-53Hz for 50Hz nominal |
 |
| Crest Factor |
up to 5 : 1 |
 |
|
** The time to recharge to 90% of full battery capacity following
a discharge to shutdown using a load rated for 1/2 the full
load rating of the UPS.
|
 |
 |
| Input
|
 |
| Nominal input voltage |
200 V |
 |
| Input frequency |
50/60 Hz +/- 5 Hz (auto sensing) |
 |
| Input Connection Type |
| NEMA L6-30P (30A
Twist-Lock) |
|
|
 |
| Cord Length |
6 feet |
 |
Input voltage range
for main operations |
155 - 276 V |
 |
 |
| Batteries
|
 |
Typical backup time
at half load |
29.1 minutes (700 Watts) |
 |
Typical backup time
at full load |
12.3 minutes (1400 Watts) |
 |
| Runtime Chart |
Symmetra RM |
 |
| Battery type |
Maintenance-free sealed Lead-Acid battery with suspended electrolyte
: leakproof |
 |
| Typical recharge time ** |
4 hour(s) |
 |
| Replacement battery cartridge |
(1) UPS Battery Replacement
|
 |
| Liquid Electrolyte Value |
0.0 |
 |
 |
| Physical
|
 |
| Maximum height dimensions |
14.00 inches ( 35.56 cm) |
 |
| Maximum width dimensions |
19.00 inches ( 48.26 cm) |
 |
| Maximum depth dimensions |
28.75 inches ( 73.03 cm) |
 |
| Rack Height |
8 U |
 |
| Net weight |
164.00 lbs ( 74.55 kg) |
 |
| Shipping Weight |
185.00 lbs ( 84.09 kg) |
 |
| Shipping Height |
20.00 inches ( 50.80 cm) |
 |
| Shipping Width |
23.00 inches ( 58.42 cm) |
 |
| Shipping Depth |
31.00 inches ( 78.74 cm) |
 |
| Color |
Beige |
 |
 |
| Communications
& Management |
 |
| Interface port |
DB-9 RS-232, RJ-45 10 Base-T Ethernet for web/ SNM |
 |
| Smart Slot Interface Quantity |
1 |
 |
| Pre-Installed SmartSlot Cards |
AP9606 |
 |
| Control panel |
Multi-function LCD status and control console |
 |
| Audible alarm |
Alarm when on battery : distinctive low battery alarm : configurable
delays |
 |
| Emergency Power Off (EPO) |
Yes |
 |
 |
| Environmental
|
 |
| Operating Environment |
0 - 40 °C (32 - 104°F) |
 |
| Operating Relative Humidity |
0 - 95% |
 |
| Operating Elevation |
0-10000 feet (0-3000 m) |
 |
| Storage Temperature |
-15 - 45 °C (5 - 113°F) |
 |
| Storage Relative Humidity |
0 - 95% |
 |
| Storage Elevation |
0-50000 feet (0-15000 m) |
 |
| Audible noise at 1 meter from surface of unit |
62 dBA |
 |
| Online thermal dissipation |
590 BTU/hr |
 |
 |
| Conformance
|
 |
| Approvals |
UL 1778, VCCI |
 |
| Standard warranty |
2 years repair or replace, optional on-site warranties available, optional
extended warranties available |
 |
* Without TAX/VAT
|
|
** The time to recharge to 90% of full battery capacity following a discharge
to shutdown using a load rated for 1/2 the full load rating of the UPS.
|
 |
|