Features & Benefits
|
Availability
|
| Modular design |
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules. |
| Configurable for N+1 internal redundancy |
Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load. |
| Hot-swappable power modules |
Ensures clean, uninterrupted power to protected equipment during Power Module replacement. |
| Hot-swappable intelligence modules |
Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement. |
| Hot-swappable batteries |
Ensures clean, uninterrupted power to protected equipment throughout battery replacement. |
| Power Modules connected in parallel |
Enhances availability by allowing immediate, seamless recovery from isolated module failures. |
| Battery modules connected in parallel |
Delivers higher availability through redundant batteries. |
| Redundant Intelligence Modules |
Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions. |
| Automatic internal bypass |
Supplies utility power to the connected loads in the event of a UPS overload condition or fault. |
| |
Economy
|
| Fully-rated power kVA equals kW |
Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads. |
| Input Power Factor Correction |
Minimizes installation costs by enabling the use of smaller generators and cabling. |
| Scalable Power Capacity |
Reduces UPS over-sizing costs today by allowing quick upgrades later. |
| Scalable runtime |
Allows quick addition of more runtime when needed. |
| Temperature-compensated battery charging |
Prolongs battery life by regulating the charge voltage according to actual battery temperature. |
| |
Serviceability
|
| Automatic self-test |
Ensures early detection of potential problems by periodic testing of UPS components. |
| User-replaceable power modules |
Enables simple upgrades and replacements of the Power Modules. |
| User-replaceable intelligence modules |
Enables simple upgrades and replacements of the Intelligence Modules. |
| User-replaceable batteries |
Enables simple upgrades and replacement of the Batteries. |
| Front-access servicing |
Simplifies installation and maintenance while minimizing space requirements |
| |
Manageability
|
| Network manageable |
Provides remote management of the UPS over the network. |
| InfraStruXure Manager Compatible |
Enables centralized management via APC's InfraStruXure Manager. |
| Manageable external batteries |
Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime. |
| Intelligent Battery Management |
Provides higher availability through intelligent precision-charging that maximizes battery performance, life, and reliability. |
| LCD display |
Manage the UPS locally through a text-based display that allows quick diagnosis via stored alarm conditions and events |
| Programmable Frequency |
This UPS automatically provides 50 or 60 Hz, and can be user-set to either value, including desired tolerances. |
| LED status indicators |
Quickly understand UPS status with indicators. |
| Audible Alarms |
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. |
| SmartSlot |
Customize UPS capabilities with management cards. |
| |