| Models |
850VA |
1.15kVA |
1.4kVA |
1.8kVA |
2.1kVA |
3.1kVA |
4.3kVA* |
7kVA* |
| Part
Number |
FES850 |
FES1.15 |
FES1.4 |
FES1.8 |
FES2.1 |
FES3.1 |
FES4.3 |
FES7 |
| Capacity
(kVA/kW) |
.8/.6 |
1.15/.8 |
1.4/1 |
1.8/1.25 |
2.1/1.5 |
3.1/2.2 |
4.3/3 |
7/5 |
| Input
- Hardwired Connection Circuit Breaker Requirement* |
120/10A
208/5A
240/5A |
120/15A
208/10A
240/5A |
120/15A
208/10A
240/10A |
120/20A
208/15A
240/10A/ |
120/25A
208/15A
240/15A |
120/35A
208/20A
240/15A |
120/40A
208/25A
240/20A |
120/65A
208/40A
240/35A |
| Output
Connection |
Hardwired
output is standard. Contact factory for receptacle
options. |
| Efficiency
% (on-line) |
85 |
88 |
88 |
90 |
90 |
91 |
90 |
90 |
Heat
(on-line)
BTU/hr
kW/hr |
361
0.106 |
372
0.109 |
465
0.136 |
474
0.139 |
568
0.166 |
742
0.217 |
1138
0.333 |
1896
0.556 |
Typical
Runtime
full load
half load
(minutes) |
11
28 |
19
49 |
14
36 |
31
73 |
24
58 |
14
35 |
26
61 |
12
33 |
| Battery
Charger (DC) |
12V,
4A |
12V,
8A |
48V,
4A |
48V,
5A |
Weight
lbs
kg
(incl. batteries) |
62
28 |
79
36 |
85
39 |
132
60 |
154
70 |
183
83 |
196
89 |
256
116 |
Dimensions
inches
mm
HxWxD |
9.75 x 16 x 21.25
248 x 406 x 540 |
9.75 x 16 x 26.25**
248 x 406 x 667 |
19 x 16 x 26.25
483 x 406 x 667 |
Front
Panel
inches
mm
HxW |
10.5 x 19
267 x 483 |
10.5 x 19
267 x 483 |
19.25 x 19
489 x 483 |
Battery
Pack
inches
mm
HxWxD |
internal |
internal |
8.3x16.25x24.25
211x413x616 |
| Operation |
| Nominal
Input Voltage |
120/208/240 |
| Input
Voltage Range |
+15%,
-20% |
| Input
Power Factor |
0.98 |
| Nominal
Output Voltage |
120/208/240 |
| Output
Voltage Regulation |
±
3% for input voltages of + 15% to -20% |
| Output
Voltage Waveform |
Sine
wave |
| Output
Voltage THD |
5%
or less at rated kW load |
| Overload
Capacity |
150%
surge and 125% for 10 minutes on-line,
150% surge and 110% for 10 minutes on inverter |
| Transfer
Time |
0
ms |
| Lightning,
Surge & Noise Protection |
2000:1
spike attenuation using ANSI/IEEE C62.41 Category A and
Category B tests.
Common Mode - >120dB. Normal Mode - >60dB |
| Efficiency |
85 |
86 |
85 |
88 |
88 |
90 |
90 |
91 |
| Safety
Certification |
UL,
CSA (cUL) |
| EMI
Compliance |
FCC
Class A |
| Testing
Standards |
ANSI/IEEE
C62.41 (1980); ANSI/IEEE C62.45 (1987); IEC 801-2, 801-4,
801-5 |
| Communication |
RS-232
serial port (DB-25), plus contact closures |
| Environmental |
| Operating
Temperature |
0†
to 40† C |
| Storage
Temperature |
-20†
C to +60† C (-20† C to +40† C if battery is not
removed.) |
| Relative
Humidity |
0
to 95% without condensation |
| Ventilation
Requirement |
Clean,
dust-free air, free of corrosive chemicals
or other contaminants with proper air circulation. |
| Audible
Noise (dBA) |
48 |
50 |
50 |
50 |
50 |
51 |
50 |
52 |
| High-Altitude
Operation |
Maximum
ambient operating temperature drops by 1† C per 305 meters
(1000 feet) above sea level with the maximum elevation
being 3,050 meters (10,000 ft). |
| All
specifications subject to change without notice. |
* Includes front panel keypad and display.
** 1.8, 2.1 and 3.1kVA models can be configured with 21.25
depth. Consult factory. |