AC
Circuit Specifications:
Initial Clamping Level: 200volts
UL 1449 Surge Protection Rating: 330 volts.
Protection Modes: Line to Neutral, Line to Ground,
Neutral to Ground.
Line Voltage: 120 VAC, 50/60 Hz.
Maximum Current Rating: 15 Amperes (1800 watts).
EMI/RFI Noise Filtration: 50dB (99.7%) from 100kHz
to 1MHz.
Response Time: Instantaneous, <1 Nanosecond.
Energy Dissipation: 672 Joules.
Peak Impulse Current: 40,000 amperes.
Catastrophic Surge Circuit: Shuts off power automatically,
preventing damage from massive surges, even lightning.
Thermal Fuse: In the event of extended overvoltage,
shuts off power to connected equipment, preventing damage.
Safety: UL-listed, CSA-certified.
Warranty: Limited two years, parts and factory
service. Limited "Double Lifetime" Warranty
on lightning and surge suppression. |
Telecommunication
Specifications (Mod Tel/1A, Mod LL/1A, MOD
LL/2, Mod CO/4, Mod DS/2):
Connection: RJ-11/45 modular jacks.
Clamping Level: 240 volts: TEL/1A, CO/4; 70 volts:
LL/1A, LL/2, DS/2.
Capacitance: 50pf (approx.)
Suppression Modes: Metallic and longitudinal.
Fuseless: Automatically disconnects from the telephone
line under surge current conditions. Automatically reconnects
after the fault condition is no longer present.
LAN
UTP Specifications:
Connections: RJ-45 modular jacks.
Clamping Level: 7 volts.
Suppression Mode: All pins to ground.
RS-232 SPECIFICATIONS (MOD RS/1A, MOD RS/2):
Clamping Level: 30 volts.
Pins Protected: 1-8.
|