| Features & Benefits |
The GarrettCom Magnum 12KX Gigabit Managed Switch provides 16 Gigabit combo ports with built-in SFPs – allowing a choice of fixed 10/100/1000 BASE-TX connectivity or fiber SFPs. The substation-hardened Magnum 12KX has a non-blocking switching fabric to provide wire-speed performance on all ports.
Ordering Information
| Models |
Description |
| Magnum 12KX Switches, models with Dual Internal Power Supplies |
| Magnum 12KX-2H |
Magnum 12KX Managed L2 or L3 Switch, front-mount, with two ACDC "high" internal Power Supplies for redundancy. Sixteen Gb ports, each of which are "combo" auto-negotiating RJ45 copper or SFP12KX for Gb or 100Mb fiber ports with IEEE 1588v2 Precision Timing. Heavy-duty case, convection cooled. Includes RJ11 console port, plus a USB interface for auto-configuration and saving, and an alarm contact for signaling power loss. Choose either Layer 2 software (default) or optional Layer 3 software, factory installed. |
| Magnum 12KXR-2H |
Same as Model 12KX-2H except chassis is a Reverse Mount unit. (All signal and power cables are in the rear). |
Magnum 12KX-2L |
Magnum 12KX Managed L2 or L3 Switch, front-mount, with two 24V-to-48V-nominal "low" DC internal Power Supplies for redundancy. Sixteen Gb ports, each of which are "combo" auto-negotiating RJ45 copper or SFP12KX for Gb or 100Mb fiber ports with IEEE 1588v2 Precision Timing. Heavy-duty case, convection cooled. Includes RJ11 console port, plus a USB interface for auto- configuration and saving, and an alarm contact for signaling power loss. Choose either Layer 2 software (default) or optional Layer 3 software, factory installed |
| Magnum 12KXR-2 |
Same as Model 12KX-2L except chassis is a Reverse Mount unit. (All signal and power cables are in the rear). |
| Magnum 12KX Switches, models with one Internal Power Supplies |
| MNS-12KS-L2-LIC |
MNS-12KS licensed Layer 2 software for use on one Magnum 12KX Switch. License cost included with each Magnum 12KX Switch base unit that is factory configured for Layer 2 Switch operation. MNS-12K Release 1.1 includes support for CLI and scripts, MSTP, RSTP 802.1w and MRP, event log file, Syslog, SNMPv1, v2, SNMPv3 for access authentication, RMON, port mirroring, address conflict detection, network error detection, SFP speed-sensing and diagnostics (temperature, optical power), port security, SSL, SSH, RADIUS authentication per 802.1x, QoS 4 classes, port priority per IEEE 802.1D/p, VLANs per IEEE 802.1q, multicast support for IGMP snooping/querier, unknown multicast detection, broadcast/unicast/multicast limiter, GMRP IEEE 802.1d, flow control 802.3x. Documentation and updates via Internet and GCI FTP Server. |
| MNS-12KS-L3-LIC |
MNS-12KS licensed Layer 3 software for use on one Magnum 12KX Switch. License cost included with each Magnum 12KX Switch base unit that is factory configured for Layer 3 Switch operation. Provides Layer 2 software features plus additional Layer 3 features, including full wire-speed IPv4 routing with low latency Multi-netting (Aliasing), Net-directed broadcasts, QoS 8 classes, Port-based Router interfaces, Proxy ARP, Static routing with ECMP (Equal Cost Multiple Path), VLAN-based router interfaces, CIDR (Classless Inter-Domain Routing), ICMP Router Discovery (IRDP), Double VLAN Tagging, Protocol-based VLANs Multicast Routing (DVMRP, IGMPv1/v2/v3, Multicast routing and IGMP Unknown Multicast Filtering, PIM-DM), Router Redundancy (VRRP, VRRP tracking, Interface Tracking), OSPFv2, Ping Tracking, RIPv1, RIPv2, and Tracking of static routes. Documentation and updates via Internet and GCI FTP Server. |
| CONSOLE-CBL-12KX |
Magnum 12KX console attachment cable, serial configuration cable. |
| ACA21-USB-12KX |
Magnum 12KX USB auto-configuration adapter for local configuration management. |
| CONFORM05-12KX |
Conformal coating, for protection against moisture. Coats interior PCBs, power supply, and modules of one Magnum 12KX Managed Switch product. |
Technical Specification
| General technical specification |
| Dimensions W x D x H |
| without bracket |
17.6 x 1.7 x 13.6 in (448 x 44 x 345 mm) |
| Weight |
12KX, 12KXR
(single power supply) |
max. 9.3 lbs (4.2 kg) |
12KX, 12KXR
(dual power supply) |
max. 9.7 lbs (4.4 kg) |
12KX, 12KXR
(single PoE power supply) |
max. 10.1 lbs (4.6 kg |
| Power Supply unit type "H" |
| Nominal voltage AC |
100 - 240 V, 50 - 60 Hz |
| Voltage range AC |
90 - 265 V, 47 - 63 Hz |
| Nominal voltage DC |
110 - 250 V |
| Voltage range DC |
77 - 300 V |
| Connection type |
3-pin terminal block |
| Power failure bridging |
> 20 ms at 230 V AC |
| Fuse |
Built into the power unit |
| Power Supply unit type "L" |
| Nominal voltage DC |
24 - 48 V |
| Voltage range DC |
18 - 60 V |
| Connection type |
3-pin terminal block |
| Power failure bridging |
> 10 ms at 20.4 V DC |
| Fuse |
Built into the power unit |
| Signal contact |
| Nominal value for AC |
2 A at 230 V AC (500 VA) |
| Nominal value for DC |
2 A at 30 V DC |
| 0.2 A at 125 V DC |
| 0.1 A at 250 V DC |
| Connection type |
2-pin terminal block |
| Environment |
| Storage temperature |
Standard: -40 °C to +70 °C |
| (ambient air) |
Extended: -40 °C to +85 °C |
| Humidity |
5% to 95% (non-condensing) |
| Air pressure |
Up to 2000 m (795 hPa) |
| Operating temperature |
| Extended (surrounding air) |
-40 °C to +85 °C |
| Pollution degree |
2 |
| Protection classes |
| Laser protection |
Class 1 according to EN 60825-1 (2001) |
| Protection class |
IP 30 |
| EMC and immunity |
| EMC interference immunity IEC/EN 61850- 3:2002 EMI TYPE tests, test in comp. with |
Description |
Test level |
| IEC/EN 61000-4-2 |
Electrostatic discharge:
|
|
| Contact discharge: |
+/- 8 kV |
| Air discharge: |
+/- 15 kV |
| IEC/EN 61000-4-3 |
Electromagnetic field: |
|
| 80 - 2,700 MHz: |
20 V/m |
| IEC/EN 61000-4-4 |
Fast transients (burst): |
|
| DC power line: |
+/- 4 kV (2.5 kHz) |
| AC power line: |
+/- 4 kV (2.5 kHz) |
| Data line: |
+/- 4 kV (2.5 kHz) |
| IEC/EN 61000-4-5 |
Voltage surges: |
|
| DC power line: |
+/- 2 kV line/earth; +/- 1 kV line/line |
| AC power line: |
+/- 4 kV line/earth; +/- 2 kV line/line |
| Data line: |
+/- 4 kV line/earth |
| IEC/EN 61000-4-6 |
Line-conducted interference: |
|
| voltages: |
10 V |
| 150 kHz - 80 MHz: |
|
| IEC/EN 61000-4-12 |
Damped vibration |
|
| DC power line: |
+/- 2.5kV line/earth; +/- 1kV line/line |
| AC power line: |
+/- 2.5kV line/earth; +/- 1kV line/line |
| Data line: |
+/- 2.5kV line/earth; +/- 1kV line/line |
| IEC 60255-5 |
Dielectric strength |
|
| DC power line, power unit type L |
500 VAC |
| AC power line, power unit type H |
2000 VAC |
| DC power line, power unit type H |
2000 VAC |
| Signal contact type L and H |
2000 VAC |
| EMC interference immunity IEEE 1613:2009 EMI TYPE tests, test in comp. with |
Description |
Test level |
| IEEE C37.90.3 |
Electrostatic discharge: |
|
| Contact discharge: |
+/- 8 kV |
| Air discharge: |
+/- 15 kV |
| IEEE C37.90.2 |
Electromagnetic field: |
|
| 80 - 1,000MHz: |
35 V/m (peak) |
| IEEE C37.90.1 |
Fast transients (burst) |
|
| DC power line |
+/- 4 kV (2.5 kHz) |
| AC power line |
+/- 4 kV (2.5 kHz) |
| Data line |
+/- 4 kV (2.5 kHz) |
| IEEE C37.90.1 |
Damped vibration |
|
| DC power line |
+/- 2.5kV line/earth; +/- 1kV line/line |
| AC power line |
+/- 2.5kV line/earth; +/- 1kV line/line |
| Data line |
+/- 2.5kV line/earth; +/- 1kV line/line |
| EMC interference immunity IEEE 1613:2009 EMI TYPE tests, test in comp. with |
Description |
Test level |
| IEEE C37.90 |
H.V. impulse |
|
| DC power line |
+/- 5 kV line / earth |
| AC power line |
+/- 5 kV line / earth |
| IEEE C37.90 |
Dielectric strength |
|
| DC power line, power unit type L |
500 VAC |
| AC power line, power unit type H |
2000 VAC |
| DC power line, power unit type H |
2000 VAC |
| Signal contact type L and H |
2000 VAC |
| EMC emitted interference |
| EN 55022 |
Class A |
| FCC 47 CFR Part 15 |
Class A |
| German Lloyd |
Classification + Construction Guidelines VI-7-3 Part 1 Ed.2001 |
| Environment type tests, test in comp. with |
Description |
Test level |
| IEC 60068-2-1 |
Cold |
-40 °C, 16 hours |
| IEC 60068-2-2 |
Dry heat |
+85 °C, 16 hours |
| IEC 60068-2-30 |
Relative humidity |
95 % (non condensing) |
| |
55 °C, 4 cycles |
| IEC 60068-2-6 |
Vibration, test Fc |
2- 9 Hz with 3 mm amplitude |
| |
1 g at 9 - 150 Hz |
| |
1.5 g at 200 - 500 Hz |
| IEC 60068-2-27 |
Shock, test Ea |
15 g at 11 ms |
| Network range |
| TP port |
| Length of a twisted pair segment |
max. 100 m / 328 ft (cat5e cable with 1000BASE-T) |
| Model (SFP-12KX-...) |
Wave length |
Fiber |
System Attenuation |
Distance |
Fiber Data |
| SFP12KX-FXMM2 |
MM
1310nm |
50/125 μm |
0-8 dB |
0-5 km |
1.0 dB/km,
800 MHz*km |
| SFP12KX-FXMM2 |
MM
1310nm |
62.5/125 μm |
0-11 dB |
0-4 km |
1.0 dB/km,
500 MHz*km |
| SFP12KX-FXSM25 |
SM
1310nm |
9/125 μm |
0-13 dB |
0-25 km |
0.4 dB/km;
3.5 ps/(nm*km) |
| SFP12KX-FXSM100 |
SM
1550nm |
9/125 μm |
10-29 dB |
40-104 km |
0.25 dB/km;
19 ps/(nm*km) |
| Model (SFP-12KX-...) |
Wave length |
Fiber |
System Attenuation |
Distance |
Fiber Data |
| SFP12KX-SX |
MM
850nm |
50/125 μm |
0-7.5 dB |
0-5 km |
3.0 dB/km,
400 MHz*km |
| SFP12KX-SX |
MM
850nm |
62.5/125 μm |
0-7.5 dB |
0-4 km |
3.2 dB/km,
200 MHz*km |
| SFP12KX-LX25 |
SM
1310nm |
9/125 μm |
0-11 dB |
0-20 km |
0.4 dB/km;
3.5 ps/(nm*km) |
| SFP12KX-ZX40 |
SM
1550nm |
9/125 μm |
5-20 dB |
14-42 km |
0.4 dB/km;
3.5 ps/(nm*km) |
| SFP12KX-ZX70 |
SM
1550nm |
9/125 μm |
6-22 dB |
24-72 km |
0.25 dB/km;
19 ps/(nm*km) |
| Note: MM = Multimode, SM = Singlemode |
| Power consumption/power output |
| Models without PoE (12KX, 12KXR) |
Maximum power consumption |
Maximum power output |
| Device (without SFP modules, without TP links) |
10 W |
34 Btu (IT)/h |
| - additionally for each connected SFP module |
1 W |
3 Btu (IT)/h |
| - additionally for each TP port with link |
0.8 W |
3 Btu (IT)/h |
| Device at full capacity (16 links) |
26 W |
88 Btu (IT)/h |
| Models with PoE (12KX, 12KXR) |
Maximum power consumption |
Maximum power output |
| Device (without SFP modules, without TP links) |
10 W |
34 Btu (IT)/h |
| - additionally for each connected SFP module |
1 W |
3 Btu (IT)/h |
| - additionally for each TP port with link |
0.8 W |
3 Btu (IT)/h |
- additionally for each TP port with link when one
Class0-PD (powered device) is connected |
19.5 W |
12 Btu (IT)/h |
- Device at full capacity with 4 x Class0-PD
(powered device) connected |
100 W |
136 Btu (IT)/h |
| Underlying norms and standards |
| Name |
Description |
| EN 61000-6-2:2005 |
Generic norm – immunity in industrial environments |
| EN 55022:2006 + A1:2007 |
IT equipment – radio interference characteristics |
| IEC/EN 60950-1:2006 |
Safety for the installation of IT equipment |
| EN 61131-2:2007 |
Programmable logic controllers |
| EN 50121-4:2006 |
Railway applications - EMC - emitted interference and interference immunity for signal and telecommunication systems |
| FCC 47 CFR Part 15:2009 |
Code of Federal Regulations |
| Germanischer Lloyd |
Ship Applications - Classification and Construction Guidelines
VI- 7-3 Part 1 Ed.2003 |
| cUL 508:1998 |
Safety for Industrial Control Equipment |
| EN 61850-3 |
Communications networks and systems in stations |
| IEEE 1613 |
Standard Environment and Testing Requirements for Communication Networking Devices in Electric Power Substations |
| IEEE 802.1 D |
Switching, GARP, GMRP, Spanning Tree |
| IEEE 802.1 D-1998 |
Media access control (MAC) bridges (includes IEEE 802.1p
Priority and Dynamic Multicast Filtering, GARP, GMRP) |
| IEEE 802.1 Q |
Tagging |
| IEEE 802.1 Q-1998 |
Virtual Bridged Local Area Networks (VLAN Tagging, GVRP) |
| IEEE 802.1 w.2001 |
Rapid Reconfiguration |
| IEEE 802.3-2002 |
Ethernet |
Features & Benefits
The models differ with regard to the range of software functions, the number of interfaces, and the media type for connecting segments.
• The Magnum 12KX devices are Substation hardened Switches with 16 Gigabit combo Ethernet ports (10/100/1000 Mbit/s, can be connected optically or with TX). These ports are suitable for the connection of terminal devices or network segments according to the standards IEEE802.3 100/ 1000BASE-FX (SFP slot) and IEEE 802.3 1000BASE-T /100BASE-TX / 10BASE-T (RJ45 socket). A plugged SFP module switches the TX port off. Reverse mount switches, such as 12KXR-2H, have an additional V.24 port on the front of the device that you can use for diagnosis and configuration purposes.
• The PoE devices support PoE (Power over Ethernet) in accordance
with IEEE 802.3af. The PoE ports are the Gigabit Ethernet ports 1
to 4.
• The Reverse mount devices, all the cable outlets are at the back, i.e. the
ports are on the back of the device. The devices also provide you with
the following options for selecting the variant you desire:
Voltage range:
Power unit 1 and optional power unit 2:
• 18 V DC to 60 V DC
• 77 V DC to 300 V DC
• 90 V AC to 265 V AC
The voltage supply connection is clampable. In devices with PoE, power supply unit 2 is the PoE power supply unit. You can choose the connections to power supply unit 1.
Software variant:
Layer 2 Professional (default)
Layer 3 Professional (optional)
The devices comply with the specifications of the standard(s):
• ISO/IEC 8802-03 10BASE-T/100BASE-TX/1000BASE-T
• ISO/IEC 8802-03 100BASE-FX
• ISO/IEC 8802-03 1000BASE-SX/LX
The Magnum 12KX device contains all the function units, such as: Switch function, management function, redundancy function, voltage connection, and management connection.
• Specific functions of TP/TX interface
• Link Control
• Auto Polarity Exchange
• Auto negotiation
• Auto crossing (device may be connected with a crossed-over or an uncrossed cable)
• Specific functions of fiber optic interface
• Link Down monitoring
The Magnum 12KX devices are Switches with a fixed configuration.
Description of model variants
12KX-2H, 12KX-2L, 12KX-1H, 12KX-1L with 16 Gigabit ports |

Click image for enlargement |
1 – 12KX switch
2 - LED display elements
3 - USB interface
4 - V.24 connection for external management
5 - 4 x Gigabit Ethernet combo ports: 100/1000 Mbit/s fiber optic SFP
slots. Alternative connections: 10/100/1000 Mbit/s twisted pair, RJ45
connections
Back of device:
6 - P1: Connection for the voltage supply
7 - Relay 1: signal contact
Back of device for device variants with 2 power supply units:
8 - P2: Connection for redundant voltage supply
9 - Relay 2: signal contact |
| 12KX-1H1POE, 12KX-1L1POE with 16 Gigabit ports and PoE |

Click image for enlargement |
1 – 12KX PoE switch
2 - LED display elements
3 - USB interface
4 - V.24 connection for external management
5 - 4 x Gigabit Ethernet combo ports with Power over Ethernet (PoE):
100/1000 Mbit/s fiber optic SFP slots. Alternative connections: 10/100/ 1000
Mbit/s twisted pair, RJ45 connections
6 - 4 x Gigabit Ethernet combo ports: 100/1000 Mbit/s fiber optic SFP
slots. Alternative connections: 10/100/1000 Mbit/s twisted pair, RJ45
connections
Back of device:
7 - P1: Connection for the voltage supply
8 - Relay 1: signal contact
Back of device for device variants with 2 power supply units:
9 - P2: Connection for the PoE voltage supply
10 - Relay 2: signal contact
|
| 12KXR-2H, 12KXR-2L, 12KXR-1H, 12KXR-1L with 16 Gigabit ports, ports on rear |

Click on the image for enlargement |
Back of device:
1 – 12KXR switch
2 - LED display elements
3 - USB interface
4 - V.24 connection for external management
5 - 4 x Gigabit Ethernet combo ports: 100/1000 Mbit/s fiber optic SFP
slots. Alternative connections: 10/100/1000 Mbit/s twisted pair, RJ45 connections
6 - P1: Connection for the voltage supply
7 - Relay 1: signal contact
For device variants with 2 power supply units:
8 - P2: Connection for redundant voltage supply
9 - Relay 2: signal contact
Front of device:
10 - LED device status display elements
11 - LED port status display elements
12 – LED service port display element
13 - Service port
|
| 12KXR-1H1POE, 12KXR-1L1POE with 16 Gigabit ports and PoE, ports on rear |

Click on image for enlargement |
Back of device:
1 – 12KXR PoE switch
2 - LED display elements
3 - USB interface
4 - V.24 connection for external management
5 - 4 x Gigabit Ethernet combo ports with Power over Ethernet (PoE):
100/1000 Mbit/s fiber optic SFP slots. Alternative connections: 10/100/ 1000
Mbit/s twisted pair, RJ45 connections
6 - 4 x Gigabit Ethernet combo ports: 100/1000 Mbit/s fiber optic SFP
slots. Alternative connections: 10/100/1000 Mbit/s twisted pair, RJ45
connections
7 - P1: Connection for the voltage supply
8 - Relay 1: signal contact
For device variants with 2 power supply units:
9 - P2: Connection for redundant voltage supply
10 - Relay 2: signal contact
Front of device:
11 - LED device status display elements
12 - LED port status display elements
13 - LED service port display element
14 - Service port
|
PoE ports
The Magnum 12KX PoE and reverse mount 12KXR PoE models support Power over Ethernet (PoE) in accordance with IEEE 802.3af on ports 1 to 4.
They allow the connection and remote supply of, for example, IP telephones (Voice over IP), webcams, sensors, printer servers and WLAN access points via 10BASE-T/100BASE-TX/1000BASE-T. With PoE, these terminal devices are powered by the twisted-pair cable.
The 12KX PoE and 12KXR PoE provide four 10BASE-T/100BASE-TX/ 1000BASE-T ports (RJ45 sockets) for connecting network segments or PoE terminal devices (PD, Powered Device) for all IEEE802.3af classes up to a maximum power output of 15.4 W.
The 4 PoE-capable ports are the 4 first ports on the device (ports 1 to 4, see fig. 2 and fig. 4). The current is supplied on wire pairs transmitting the signal (pins 1, 2, 3 & 6). The individual ports are not electrically insulated from each other. (see page 28 "10/100/1000 Mbit/s twisted pair connection")
The following conditions are met in accordance with IEEE 802.3af:
• Endpoint PSE
• Alternative A
Combo ports
At the four Gigabit Ethernet combo ports (see fig. 1 to fig. 4) you can connect either F/O (via SFP modules) or twisted pair port (via RJ45).
• SFP modules: SFP modules are optical transceivers (Fast Ethernet and Gigabit Ethernet SFP modules, see pages 10-11). SFP stands for Small Form-factor Pluggable and is also frequently referred to as mini-GBIC (GigaBit Interface Converter). The SFP modules are plugged into the SFP slots of the Magnum 12KX device in order to obtain an F/O port. The 12KX has 16 TP interfaces and 16 slots for inserting SFP modules (100/1000 Mbit/s). By inserting the SFP module you deactivate the corresponding TP interface.
Note: Only use GarrettCom SFP modules
|