GarrettCom » DX Family » DX900

 GarrettCom Magnum DX900: SCADA / EMS / DMS Industrial Rugged Layer 3 Router

This product is now discontinued, and replaced by DX940
For any additional support please Contact Bomara



Overview:

  • Family of Rugged Layer 3 switches for harsh Environments
  • Harsh environment router
  • Supports public or private digital facilities


Description:

The Magnum DX900 Industrial Router enables remote network connectivity to substations, transportation systems, and other remote industrial sites using Digital WAN services such as DDS, T1/E1, frame relay, TDM, IP and MPLS-based VPN services. The DX900's versatility increases cost effectiveness via offering a combination of WAN access, IP routing, Ethernet switching, Serial IP terminal services and advanced security features in a single device. Compact packaging make the DX900 ideal for smaller and mid-sized remote sites such as distribution substations and transportation control pedestals.



  • Ordering Information
  • Specifications
  • Features



Magnum DX900 Ordering Information:

Model Description
Units - Panel Mounting
DX900-01-H-P DX900, DDS, 4Serial, 4TX, 90-250Vdc/Vac, Panel - Magnum DX900 Industrial Router, hardened.  One DDS WAN port w/integral DSU/CSU, 4 RS232/RS485/RS422 software selectable serial ports, 4 10/100 TX Ethernet Switch ports. AC Power Supply, panel mounting. Includes IP routing, Serial-IP terminal services, Ethernet switching, TCP/IP firewall, IPsec VPN, SCADA Frame Forwarding and secure management.  MNS-DX license included.
DX900-01-L-P DX900, DDS, 4Serial, 4TX, 90-250Vdc/Vac, Panel - Magnum DX900 Industrial Router, hardened.  One DDS WAN port w/integral DSU/CSU, 4 RS232/RS485/RS422 software selectable serial ports, 4 10/100 TX Ethernet Switch ports. 24-48 VDC Power Supply, panel mounting. Includes IP routing, Serial-IP terminal services, Ethernet switching, TCP/IP firewall, IPsec VPN, SCADA Frame Forwarding and secure management.  MNS-DX license included.
DX900-03-H-P DX900, T1/E1, 4Serial, 4TX, 90-250Vdc/Vac - Magnum DX900 Industrial Router, hardened.  One T1/E1 WAN port w/integral DSU/CSU, 4 RS232/RS485/RS422 software selectable serial ports, 4 10/100 TX Ethernet Switch ports. AC Power Supply, panel mounting. Includes IP routing, Serial-IP terminal services, Ethernet switching, TCP/IP firewall, IPsec VPN, SCADA Frame Forwarding and secure management.  MNS-DX license included.
DX900-03-L-P DX900, T1/E1, 4Serial, 4TX, 90-250Vdc/Vac - Magnum DX900 Industrial Router, hardened.  One T1/E1 WAN port w/integral DSU/CSU, 4 RS232/RS485/RS422 software selectable serial ports, 4 10/100 TX Ethernet Switch ports. AC Power Supply, panel mounting. Includes IP routing, Serial-IP terminal services, Ethernet switching, TCP/IP firewall, IPsec VPN, SCADA Frame Forwarding and secure management.  MNS-DX license included.
Units - DIN-Rail Mounting Bracket
DX900-01-H-D DX900, DDS, 4Serial, 4TX, 90-250Vdc/Vac, DIN - Magnum DX900 Industrial Router, hardened.  One DDS WAN port w/integral DSU/CSU, 4 RS232/RS485/RS422 software selectable serial ports, 4 10/100 TX Ethernet Switch ports. AC Power Supply, DIN-Rail mounting. Includes IP routing, Serial-IP terminal services, Ethernet switching, TCP/IP firewall, IPsec VPN, SCADA Frame Forwarding and secure management.  MNS-DX license included.
DX900-01-L-D DX900, DDS, 4Serial, 4TX, 24-48Vdc/Vac, DIN - Magnum DX900 Industrial Router, hardened.  One DDS WAN port w/integral DSU/CSU, 4 RS232/RS485/RS422 software selectable serial ports, 4 10/100 TX Ethernet Switch ports. 24-48 VDC Power Supply, DIN-Rail mounting bracket.
DX900-03-H-D DX900, T1/E1, 4Serial, 4TX, 90-250Vdc/Vac - DIN - Magnum DX900 Industrial Router, hardened.  One T1/E1 WAN port w/integral DSU/CSU, 4 RS232/RS485/RS422 software selectable serial ports, 4 10/100 TX Ethernet Switch ports. AC Power Supply, DIN-Rail mounting. Includes IP routing, Serial-IP terminal services, Ethernet switching, TCP/IP firewall, IPsec VPN, SCADA Frame Forwarding and secure management.  MNS-DX license included.
DX900-03-L-D DX900, T1/E1, 4Serial, 4TX, 24-48Vdc - DIN - Magnum DX900 Industrial Router, hardened.  One T1/E1 WAN port w/integral DSU/CSU, 4 RS232/RS485/RS422 software selectable serial ports, 4 10/100 TX Ethernet Switch ports. 24-48VDC Power Supply, DIN-Rail mounting. Includes IP routing, Serial-IP terminal services, Ethernet switching, TCP/IP firewall, IPsec VPN, SCADA Frame Forwarding and secure management.  MNS-DX license included.
Optional Mounting Brackets
ACC-DX-00-RM Rack-mount brackets for one DX900 unit. Spares, or for field installation / conversion.
ACC-DX-00-RRM Reverse Rack-mount brackets for one DX900 unit. Spares, or for field installation / conversion.
ACC-DX-00-DM DIN-Rail-mount brackets for one DX900 unit. Spares, or for field installation / conversion.
ACC-DX-00-PM Panel-mount brackets for one DX900 unit. Spares, or for field installation / conversion.



Magnum DX900 Specifications:

WAN INTERFACE

  • DDS: 56/64 kbps
  • T1/E1: 1.544 Mbps / 2.048 Mbps G.703;
  • Full rate and fractional (N*56/64kbps)
  • Integral CSU/DSU
  • Frame relay, IP


SERIAL INTERFACES

  • 4 ports, RS232/RS485/RS422
    software selectable
  • 2- or 4-wire RS485
  • RS232 with optional Data Set Signaling
  • 300 bps to 230.4 kbps
  • Serial-IP terminal server /
    reverse terminal server
  • Multicast, multi-masterDNP, Modbus, Telnet
  • Modbus-ASCII/RTU to Modbus/TCP
  • SCADA Frame Forwarding


ETHERNET INTERFACES

  • 4 ports, 10/100TX auto-sensing or fixed
  • Wire speed switching
  • VLANs per 802.1Q
  • STP/RSTP per 802.1d/802.1w
  • Prioritization via 802.1p
  • Static MAC port security
  • Port security per 802.1x


IP ROUTING SERVICES

  • Routing per interface
  • Routing Per VLAN
  • Static routing, RIP, RIP-II
  • OSPF*, BGP*
  • DiffServ prioritization
  • DHCP Server


IP FIREWALL /
PERIMETER SECURITY

  • IP address and port filtering
  • Stateful inspection and logging*
  • NAT/PAT
  • IPsec VPNs
  • Serial port SSL VPNs
  • 3DES, AES, PSK, X.509

MANAGEMENT SECURITY

  • HTTPS, SSH, S-FTP, SNMPv3
  • Multilevel strong form passwords and aging
  • RADIUS
  • Management activity logging and alarms


MANAGEMENT & DIAGNOSTICS

  • Web–based Graphical User Interface (GUI)
  • CLI access via TELNET connection
  • Powerful built–in protocol analyzer
  • Layer 1 through 3 statistics
  • SNMP MIB II and SNMP Traps
  • Syslog Event Logging
  • XML–based config file
  • Multiple on-board software and config files
  • Relay contacts for alarms:
    Form C, 2 NC/NO,
    software controllable


ENVIRONMENTAL

  • Operating Temperature:
    –40C to +85C, no fans
  • Storage Temperature:
    –40C to +85C
  • Humidity:
    95% non–condensing
  • Industrial:
    IEEE1613
    IEC 61850–3
    IEC 61000–6–5
  • Emissions:
    EN55022A, FCC Part 15A
  • Safety:
    UL60950–1
    EN60950–1
    CSA C22.2

IMMUNITY

  • EN55024
  • EN61000-6-2
  • EN61000-4-2 (ESD)
  • EN61000-4-3 (RF)
  • EN61000-4-4 (EFT)
  • EN61000-4-5 (SURGE)
  • EN61000-4-6 (CRF)
  • EN61000-4-10 (MAG FIELD)
  • EN61000-4-11 (VDI)
  • EN61000-4-12 (OSCILLATION)
  • EN61000-4-16 (CCM)
  • EN61000-4-17 (RIPPLE)
  • EN61000-4-29 (VDI)

TELECOM

  • UACTA TIA/EIA IS-968A
    -(FCC part 68)
  • IC CS03
  • EN55022: 1998 Telco Port Emissions

POWER OPTIONS

  • High Voltage (H)
    90–250 Vac or Vdc, 50–60Hz
    0.3A, 27 watts
  • Low Voltage DC (L)
    24–48 Vdc
    1.3A, 31 watts

MECHANICAL

  • Dimensions:
    9.5" W x 9.0" D x 1.75" H
    (24.13 cm x 22.86 cm x 4.45 cm)
    Optional 19 inch Rack Mount, 1U
  • Weight:
    5 lbs (2.3 kg)
  • Mounting:
    Rack, Panel Mount and DIN Rail Options



Magnum DX900 Features:

  • 4 Ethernet Ports, 4 Serial Ports, WAN Port
  • Access to remote sites via Digital WANs using DDS or T1/E1, IP and Frame Relay
  • Versatile integration of IP router, Ethernet switch, Serial terminal server and security appliance
  • Network security perimeter and management security including IPsec, SSL, SSH and firewall
  • Compact panel, DIN-Rail or rack mounting with integral DSU/CSU and power supply
  • Hardened to substation EMI/ESD specs and -40 to 85 C with no fans
  • AC and DC Power Input
  • Modbus TCP is now available in MNS-DX 1.3
  • Meets IEC 61850-3 specifications for EMI/ESD protection
  • Designed for use in secure NERC CIP compliant environments
  • See also Magnum DX800 Serial Device Router, and DX40 Serial Device Router.

 




Call Us: 1-978-452-2299
First Name:
Last Name:
Company:
Address:
Mail Stop:
City:
State (if in US):
Province/Region (if outside US):
Country:
ZIP (Postal) Code:
E-mail:
Telephone:
Fax:
Questions/Comments:
Verification: Please type:
Please have a Bomara Associates representative contact me


View Full Site View Mobile Optimized