Bomara Home » Server Technology » Rack Switch PDU » CW-24V5 415V 3Ph 20/30A 12xC13 & 12xC19 with PIPS

Switched CW-24V5 415V 3Ph 20/30A 12xC13 & 12xC19 with PIPS

CW-24V5 415V 3Ph 20/30A 12xC13 & 12xC19 with PIPSThe Switched CDU combines remote configuration and management with power distribution and power and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds. Assign user specific access rights to designated outlets or groups. This Switched CDU has middle entry for network, serial & environmental connections combined with a bottom power cord entry. This provides the ultimate flexibility when connecting Switched CDU's to raised floors, overhead power or busways. Current monitors are easily inverted via the web GUI or serial interface.

  Key Features

  Ordering Information

    Request a quote

Model
Available Input
Voltages
Amperage
Available Input
Cord**
Outlets
Dimensions
(L x W x D)
CW-24V53425A9
CX-24V53425A9*
240/415V 3-Phase Wye,
50/60Hz
20A
IEC Red 6hr 3P+N+G Plug,
10'(3m), Bottom/Frt Cord
(12) IEC 60320/C13 (12) IEC 60320/C19
70.6 x 1.75 x 3.50 in. (1794 x 44 x 89 mm)
CW-24V54425A9
CX-24V54425A9*
240/415V 3-Phase Wye,
50/60Hz
30A
IEC Red 6hr 3P+N+G Plug,
10'(3m), Bottom/Frt Cord
(12) IEC 60320/C13 (12) IEC 60320/C19
70.6 x 1.75 x 3.50 in. (1794 x 44 x 89 mm)
CW-24V5Z425A9
CX-24V5Z425A9*
240/415V 3-Phase Wye,
50/60Hz
30A
NEMA L22-30P Plug,
10'(3m), Bottom/Frt Cord
(12) IEC 60320/C13 (12) IEC 60320/C19
70.6 x 1.75 x 3.50 in. (1794 x 44 x 89 mm)

* CX part numbers refer to the Expansion CDU
**Click here to view additional information on Power Cords and Cables

All models above have PIPS. PIPS - (Per Input Power Sensing) Active Power, Apparent Power, Energy k-Wh, Power Capacity, Reactance, and Power Capacity Used using the network interface. See the aggregate current draw, in Amps, locally using the onboard LED


  Additional Ordering Information


Part Number Description
CW-24V52425A9 Switched CDU with PIPS (Per Infeed Power Sensing), 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase, 20A NEMA L22-20P Connector, Middle Display and Network Access, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable

 

  Additional Features and Specifications

Agency Approvals

  • US & Canada (cTUVus mark) to UL 60950-1:2003 and CAN/CSA 22.2 No. 60950-1-03
  • FCC Class A, Part 15
  • EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A
  • CE

Communications and Security

  • 10/100 BaseT Ethernet
  • HTTP/HTTPS
  • SSLv3/TLSv1
  • SNMPv2
  • SSHv2
  • Telnet
  • LDAPS/LDAPv3
  • TACACS+
  • RADIUS
  • RS-232 (Serial)

 

Branch Circuit Protection

  • Compliant to UL 60950-1

Accessories

  • Optional Temperature & Humidity Probe
  • - EMTH-1-1 Temperature & Humidity Probe, 10ft (3m)
  • Environmental Monitor
  • - EMCU-1-1B allows up to (2) additional temperature & humidity probes, (1) water sensor, (4) dry contact closures, (1) analog-to-digital converter. Includes (1) temperature/humidity probe with unit.
  • SPM (Sentry Power Manager) Appliance:
  • - Monitor and Manage multiple Sentry CDU's
    - Monitor and Manage all alarm conditions
    - Reporting and Trending
    - Group or Cluster outlets for reboot and power information

 

1U SPM

Expansion Module Model Numbers

  • CX-24V53425A9
  • CX-24V54425A9
  • CX-24V5Z425A9

 

1U SPM Appliance

 

Additional Benefits:

Pops Branch Circuit

- Branch Circuit Protection

The Sentry CDU Family meets the UL 60950-1 requirement for Branch Circuit Protections> UL-489 rated circuit breakers

Pops Pips

- PIPS - Per Input Power Sensing

Accurately measures active power, apparent power, energy kw/h, power capacity, reactance, and power capacity consumed using the network interface. See the aggregate current draw, in amps, locally using the onboard LED.

Pops Temperature

- Temperature and Humidity

The Switched CDU supports two external probes. Each of these probes measure both temperature and humidity. Receive SNMP-based alert notifications when conditions exceed defined thresholds.

Pops Mixed Outlets

- Mixed Outlets

This Switched CDU combines both IEC 60320/C13 and IEC 60320/C19 switched outlets within a single CDU. For rebooting non-responsive servers & network devices.




Call Us: 1-978-452-2299
First Name:
Last Name:
Company:
Address:
Mail Stop:
City:
State (if in US):
Province/Region (if outside US):
Country:
ZIP (Postal) Code:
E-mail:
Telephone:
Fax:
Questions/Comments:
Verification: Please type:
Please have a Bomara Associates representative contact me


View Full Site View Mobile Optimized