Dual-Feed PTXL/PTXM-HD16
Data centers today most commonly standardize on dual-power corded servers and network gear as facility managers continue to push for improved network availability. Regardless of the power input feeds, however, servers and network gear do occasionally lock-up and require a reboot procedure to bring them back to operational status. Data Centers aiming for five 9's availability (99.999% uptime) require a remote solution to reduce Mean Time to Repair (MTTR) to reduce down time and improved productivity and efficiency. The Sentry Dual-Feed Power Tower (PTXL-HD16) is designed for servers and other devices with dual or redundant power supplies. It combines intelligent power distribution, remote management, power monitoring and environmental monitoring into a single solution. The PTXL provides Remote Power Management of each power receptacle, individually or as a selected group, via Web, SSH or SNMP management. Users can individually control each power outlet to reboot network servers and internetworking devices. Or, power-off unused power outlets to prevent unauthorized power consumption on power circuit(s).The exclusive Outlet Group Control feature of the power outlet-receptacles from two diffierent power circuits allows a user to easily reboot a dual-power supply server or other device with a single command. Link an expansion unit, the PTXM, to each PTXL to control multiple power circuits with a single user interface. Input current monitoring measures the aggregate load (in amps) on each power circuit. A digital display indicator on the Power Tower provides on-site verification of the load, and the remote user interface screen reports the same current measurement.
Key Features
- Remote Management: Reboot locked-up servers and network gear via IP or out-of-band
- Power-up Sequencing of outlets prevents a power in-rush overload. User adjustable.
- Input Current Monitor: Power monitoring of the aggregate load on each power circuit (amps) remotely via the interface and locally on the enclosure.
- Authentication: Username/password required for network administrators & user accounts.
- Web GUI: Full configuration & control for managing and grouping outlets, user accounts and network settings
- Global Security Modem: Field replaceable modem can be added any time.
- Add a second tower: Connect a Power Tower Expansion Module (PTXM) to each PTXL to control up to 32 managed outlets (individual or groups).
- Outlet Grouping: Group individual outlets-between A and B Power circuits for control of dual-supply servers with a single command.
- Power Distribution: Dual 120V, 208-240V or 230V; 16A, 20A, 30A or 32A power input feeds
- RS-232 Control: Manage the Power Towers via an existing computer, KVM switch, terminal server or other serial device.
- Environmental Monitoring: Add temperature, humidity, water and intrusion monitoring with the EMCU-1-1
- SSHv2: Secure Shell for secure remote terminal
- SSLv3: Secure Sockets Layer-enabled HTTPS server.> Active Directory with LDAPSv3: User authentication with LDAPv3
Ordering Information
Request a quote
Model
|
Available Input
Voltages
|
Amperage
|
Available Input Cord
|
Outlets
|
Dimensions
(L x W x D)
|
PTXL-HD16-1-02
PTXM-HD16-1-02*
|
100-120 VAC
50/60 Hz
|
20A
|
Two IEC 60320/C20
Power Inlets
|
(16) NEMA 5-20R
|
17.2 x 3.50 x 10.0 in. (437 x 89 x 254 mm)
|
PTXL-HD16-1-05
PTXM-HD16-1-05*
|
100-120 VAC
50/60 Hz
|
30A
|
Two NEMA L5-30P Cord Sets
|
(16) NEMA 5-20R
|
17.2 x 3.50 x 10.0 in. (437 x 89 x 254 mm)
|
PTXL-HD16-2-02
PTXM-HD16-2-02*
|
208-240 VAC, 50/60 Hz
230 VAC, 50/60 Hz
|
20A
16A
|
Two IEC 60320/C20
Power Inlets
|
(16) IEC 60320/C13
|
17.2 x 3.50 x 10.0 in. (437 x 89 x 254 mm)
|
PTXL-HD16-2-06
PTXM-HD16-2-06*
|
208-240 VAC
50/60 Hz
|
30A
|
Two NEMA L6-30P Cord Sets
|
(16) IEC 60320/C13
|
17.2 x 3.50 x 10.0 in. (437 x 89 x 254 mm)
|
PTXL-HD16-2-00B PTXM-HD16-2-00B*
|
230 VAC
50/60 Hz
|
32A
|
Two IEC 60309 32 A Cord Sets
|
(16) IEC 60320/C13
|
17.2 x 3.50 x 10.0 in. (437 x 89 x 254 mm)
|
| PTXM part number refers to the expansion CDU |
Additional Features and Specifications
Agency Approvals
- US & Canada (cTUVus mark) to UL 60950-1:2003 and CAN/CSA 22.2 No. 60950-1-03
- European Union (TUVGS mark) to EN 60950-1:2001
- FCC Class A, Part 15
- CE
- EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A
Power Cord Options
- PTCORD-1-- IEC 60320/C19 - NEMA L6-20P , 10ft (3m)
- PTCORD-2 -- IEC 60320/C19 - Schuko 10ft (3m)
- PTCORD-3 -- IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10ft (3m)
- PTCORD-4 -- IEC 60320/C19 - BS1363 13A (UK) 10ft (3m)
- PTCORD-5 -- IEC 60320/C19 - 5-15P (15A Straight-Blade) 10ft (3m)
- PTCORD-6 -- IEC 60320/C19 - 5-20P (20A Straight-Blade) 10ft (3m)
- PTCORD-7 -- IEC 60320/C19 - L5-20P (20A Twist-Lock) 10ft (3m)
Communications and Security
- 10/100 BaseT Ethernet
- HTTP/HTTPS
- SSLv3/TLSv1
- SNMPv2
- SSHv2
- Telnet
- LDAPS/LDAPv3
- TACACS+
- RS-232 (Serial)
Warranty
|
Branch Circuit Protection
Accessories
- Optional Temperature & Humidity Probe
-EMTH-1-1 Temperature & Humidity Probe, 10ft (3m)
- Environmental Monitor
- EMCU-1-1B allows up to (2) additional temperature & humidity probes, (1) water sensor, (4) dry contact closures, (1) analog-to-digital converter. Includes (1) temperature/humidity probe with unit.
- SPM (Sentry Power Manager) Appliance:
- Monitor and Manage multiple Sentry CDU's
- Monitor and Manage all alarm conditions
- Reporting and Trending
- Group or Cluster outlets for reboot and power information
- Global Security Modem
- C-HPT, add out-of-band dial-up access to the PTXL Switched CDU with this v.92 data modem. Includes Callback Security feature for a higher level of security against unauthorized access.
LED Indicators
- On Sense indicates receptacle power status
- Input Current Monitor dynamically displays cumulative current load
|
| |
1U SPM Appliance |
|