Server Technology Home » HDOT (High Density Outlet Technology) Units

 Server Technology HDOT (High Density Outlet Technology) Units:

Allows IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet.

HDOT (High Density Outlet Technology)


Description:

You've never seen anything like this before. Introducing the HDOT™ (High Density Outlet Technology, Patent Pending). High power densities and reduced cabinet space require new and innovative products like Server Technology’s own patented outlet technology that provides industry standard C13 and C19 outlets in a drastically reduced footprint. The highest possible outlet density available in a network connected PDU. Up to 42 C13’s in a 42U high by 1U wide device. Additional features include high native cord retention that eliminates the need for custom and costly ancillary locking cord devices. Manufactured with robust high temperature materials carrying a UL94 V-0 ame rating makes these outlets ideally suited for harsh data center environments. To order the HDOT PDU please contact Bomara for the configuration options. HDOT technology is available in Metered and Smart PDUs.



  • Ordering Information
  • Features & Benefits
  • Specifications
  • Accessories
  • Power Cord Options
  • Additional Information


HDOT (High Density Outlet Technology) Ordering Information:

Part Number Description
CS39CS-2/E 39 HDOT IEC C13 and C19 Outlets 208V-240V 20/30A with PIPS
CS39CS-D/Y 39 HDOT IEC C13 and C19 Outlets 208V 3-Phase with PIPS
CS39CS-4 39 HDOT IEC (30) C13 and (9) C19 Outlets 400V 3-Phase 16/32A with PIPS
CS39CS-5 39 HDOT IEC (30) C13 and (9) C19 Outlets 415V 3-Phase 20/30A with PIPS
CS42CS-2/E 42 HDOT IEC C13 Outlets 208V 20/30A with PIPS
CS42CS-D/Y 42 HDOT IEC C13 and C19 Outlets 208V 3-Phase with PIPS
CS42CS-4 42 HDOT IEC C13 Outlets 400V 3-Phase 16/32A with PIPS
CS42CS-5 42 HDOT IEC C13 Outlets 415V 3-Phase 20/30A with PIPS


HDOT (High Density Outlet Technology) Features & Benefits:

Metered - The Server Technology® Metered CDU® provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet.

High Density Power Pivot
Outlet Technology

Button
Mounting

High Retention
Locking Outlets

Branch Circuit
Protection

Auto Flip
Current Display

Power Pivot

           

Smart - The integral PIPS® technology provides highly-accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Smart “Master” CDU® can be connected to the Smart “Link” CDU® to extend the network access to the redundant or secondary power feed.

High Density Power Pivot
Outlet Technology

High Retention
Locking Outlets

Branch Circuit
Protection

Auto Flip
Current Display

Power Pivot

Button
Mounting

Network
Monitoring

Per Inlet Power
Sensing

Link to an
Expansion CDU

Temperature &
Humidity Monitoring

 


HDOT (High Density Output Technology) Specifications:


Input:

Metered: Digital True RMS input current at ± 1% and 0.1 amp resolution (above 0.25 amp)
Smart: PIPS® (All products meet or exceed ANSI C12.1 for ± 1% Billing Grade Accuracy as tested by UL)
· LED Current = ± 1% at 0.1 amp resolution (above 0.25 amp)
· GUI Current = ± 1% at 0.01 amp resolution (above 0.25 amp)
· Voltage = ± 1% at 0.1 volt resolution
· Active Power = ± 2% at 1 watt resolution
· Power Factor = ± 2% at 0.01 resolution
· Crest Factor = ± 10% at 0.1 resolution
· Energy = ± 2% at 1 watt-hour resolution
Power Pivot flexible mounting power infeed.
Quiescent / Unloaded Power Draw: < 10W for all configurations

North America
Connector Cord Current Rating Voltage Rating
C20 Use PTCORD* ≤ 16A (20A max) 208V-240V L-L nominal, 50/60Hz
NEMA L6-30P 10ft, 3-conductor, 10AWG ≤ 24A (30A max) 208V-240V L-L nominal, 50/60Hz
NEMA L15-20P 10ft, 4-conductor, 12AWG ≤ 16A (20A max) 208V-240V L-L nominal, 50/60Hz
NEMA L15-30P 10ft, 4-conductor, 10AWG ≤ 24A (30A max) 208V-240V L-L nominal, 50/60Hz
NEMA L21-20P 10ft, 5-conductor, 12AWG ≤ 16A (20A max) 208V-240V L-L nominal, 50/60Hz
NEMA L21-30P 10ft, 5-conductor, 10AWG ≤ 24A (30A max) 208V-240V L-L nominal, 50/60Hz
NEMA L22-20P 10ft, 5-conductor, 12AWG ≤ 16A (20A max) 220V-240V L-N nominal, 50/60Hz
NEMA L22-30P 10ft, 5-conductor, 10AWG ≤ 24A (30A max) 220V-240V L-N nominal, 50/60Hz
IEC 60309 6hr 3P+N+PE Red Plug 10ft, 5-conductor, 12AWG ≤ 16A (20A max) 220V-240V L-N nominal, 50/60Hz
IEC 60309 6hr 3P+N+PE Red Plug 10ft, 5-conductor, 10AWG ≤ 24A (30A max) 220V-240V L-N nominal, 50/60Hz

Global

Connector Cord Current Rating Voltage Rating
C20 Use PTCORD* ≤ 16A 220V-240V L-N nominal, 50/60Hz
IEC 60309 6hr 2P+PE Blue Plug 3m, 3-conductor, H05VV-F, 4.0mm2 ≤ 32A 220V-240V L-N nominal, 50/60Hz
IEC 60309 6hr 3P+N+PE Blue Plug 3m, 5-conductor, H05VV-F, 4.0mm2 ≤ 16A 220V-240V L-N nominal, 50/60Hz
IEC 60309 6hr 3P+N+PE Blue Plug 3m, 5-conductor, H05VV-F, 4.0mm2 ≤ 32A 220V-240V L-N nominal, 50/60Hz
*PTCORD’s ordered separately. Choose L6-20P, CEE 7/7 Schuko, IEC60309 2P+E, or BS1363.


Output:

Three (3) user specified modules
Module choice:
· (14) x C13
· (12) x C13 + (1) x C19
· (11) x C13 + (2) x C19
· (10) x C13 + (3) x C19
· (9) x C13 + (4) x C19
· (7) x C13 + (5) x C19
Current Rating:
· North America C13: ≤ 12A
· Global C13: ≤ 10A
· North America C19: ≤ 16A
· Global C19: ≤ 16A
Voltage Rating: 208-240V nominal, 50/60Hz
Locking cord options available
High-retention even without locking cords


Branch Circuit Protection:

· UL489 compliant circuit breakers, 20A
· Two (2) branches on single-phase units, One (1) branch per phase-pair on three-phase 208V units.
· Two (2) branches per phase on three-phase 400 or 415V units.
· Current Rating: ≤16A; Interrupt rated at 5kAIC for 1-phase and 3-phase 208V, 10kAIC for 3-phase 400V.
· Voltage Rating: 208V-240V nominal, 50/60Hz


Physical:

· Dimensions: See drawings below
· Shipping dimensions: 91.7 x 7.10 x 7.10 in. (233 x 18.1 x 18.1 cm)
· Shipping Weight: 23 lbs (10.4 kg) for C20 inlet versions, 25 lbs (11.4 kg) for all others
· Chassis color: Black
· Highlight color: Choose Black, Red, Green, Blue, or White


Environmental Requirements:

  Operating Storage
Temperature 32° to 149° F (0° to 65° C)* -40° to 185° F (-40° to 85° C)
Relative Humidity 8% to 90% non-condensing 8% to 90% non-condensing

* 400 or 415V units rated at 60° C


Smart PDU Communications & Security:

Master PDU
· 10/100 Mbps Ethernet (RJ-45 connector)
· RS-232 serial (RJ-45 connector)
· Two (2) temperature/humidity sensor inputs (4P4C)
· Link port (RJ-12)
· Web-browser GUI and command-line-interface (CLI)
· HTTP/HTTPS, SSLv3/TLSv1, SSHv2, Telnet
· SNMPv2c and v3 (GET, SET, Traps)
· IPv4 and IPv6
· LDAPv3/LDAPS, TACACS+, RADIUS

Link PDU
· Two (2) temperature/humidity sensor inputs (4P4C)
· Link port (RJ-12)


Certifications:

North America
· cTUVus Mark to UL 60950-1:2007 and CAN/CSA 22.2 No. 60950-1-07
· EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A
· FCC Class A, Part 15
· RoHS/WEEE

Global
· TUVGS Mark to EN 60950-1:2006 + A11
· EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A
· FCC Class A, Part 15
· CE Mark
· RoHS/WEEE


HDOT (High Density Output Technology) Accessories:

EMTH-1-1 Combination Temperature/Humidity Probe, 10ft (3m)
EMCU-1-1B Environmental Monitor adding:

· Two (2) EMTH-1-1 temperature/humidity ports (one probe included)
· One (1) EMWS-1-1 water sensor port (probe sold separately)
· Four (4) dry contact (NO/NC) monitoring points
· One (1) 8-bit analog-to-digital converter (0 to 5VDC)
SPM (Sentry™ Power Manager):
· Monitor and manage multiple PDUs from a single point
· Monitor and manage alarm conditions
· Create reports and trends on stored data
· Analyze power usage per phase
· Optional appliance or virtual version
· VMware Ready.
Mounting Brackets
· Buttons (KIT-0020) included for tool-less mounting (see diagram).
· See the Mounting Bracket Guide for further suggestions.
· Custom mounting options available. Contact your local Server Technology® representative.


HDOT (High Density Output Technology) LockedIn™ Outlet Power Cord Options:


UL Rated
Part Number Plug Receptacle Length Color
CAB-S1413-CA C14 C13 1.5 ft (0.45 m) Black
CAB-S1413-FA(FR) C14 C13 3.0 ft (0.9 m) Black (Red)
CAB-S1413-NA(NR) C14 C13 6.0 ft (1.8 m) Black (Red)
CAB-S1413-WA C14 C13 10.0 ft (3 m) Black
CAB-S1419-FA C14 C19 3.0 ft (0.9 m) Black
CAB-S1419-NA C14 C19 6.0 ft (1.8 m) Black
CAB-S2013-CA C20 C13 1.5 ft (0.45 m) Black
CAB-S2013-FA C20 C13 3.0 ft (0.9 m) Black
CAB-S2013-NA C20 C13 6.0 ft (1.8 m) Black
CAB-S2019-CA C20 C19 1.5 ft (0.45 m) Black
CAB-S2019-FA(FR) C20 C19 3.0 ft (0.9 m) Black (Red)
CAB-S2019-NA(NR) C20 C19 6.0 ft (1.8 m) Black (Red)

VDE Rated
Part Number Plug Receptacle Length Color
CAB-S1413-CV C14 C13 0.5 m (20 in) Black
CAB-S1413-GV(GS) C14 C13 1.0 m (39 in) Black (Red)
CAB-S1413-PV(PS) C14 C13 2.0 m (78 in) Black (Red)
CAB-S1419-PV
(Discontinued)
C14 C19 2.0 m (78 in) Black
CAB-S2013-GV C20 C13 1.0 m (39 in) Black
CAB-S2013-PV C20 C13 2.0 m (78 in) Black
CAB-S2019-CV C20 C19 0.5 m (20 in) Black
CAB-S2019-GV(GS) C20 C19 1.0 m (39 in) Black (Red)
CAB-S2019-PV(PS) C20 C19 2.0 m (78 in) Black (Red)


Note: Additional LockedIn™ or non-locking cords may be available. Contact you local Server Technology® representative.


HDOT (High Density Outlet Technology) Features & Benefits:

Warranty: Server Technology® offers a standard 2-year limited parts & labor warranty. Extended support is available at the time of
purchase. Contact Bomara for more information.

Patents: Information on Server Technology® patents is available, please contact Bomara for the most up-to-date information.


The Build Your Own PDU configurator
The Build Your Own PDU is a patent pending modular PDU that’s exclusive to Server Technology. We’re taking our power strategy expertise to a new level, letting you design your product. We’ll take your design and build a high quality, reliable and accurate product, custom to your needs. The Build Your Own PDU configurator allows you to specify the exact PDU that you want. You’ll get exactly what you need for your operation because we custom build it to your specifications. You’ll get:

  • Custom PDUs –we’ll build them just the way you order them
  • Fast turnaround: Shipped directly to you in 3-5 days
  • Color! Choose from Red, Blue, Green or White highlights on your PDU, designed for easy identification in your data center
  • No minimum order
  • No lead time. All materials are in stock so we’re ready to start your order.

We start with a 42 outlet Smart or Metered PDU frame and take you through a step-by-step set of options where you choose your power inlet, orientation, connectivity, outlet configurator (see drawings below for mix-and-match options), color and quantity. We’ll show you what your PDU will look like and give you a final order to approve and submit for a quote. Then, we start building your custom PDUs. A few days later, they’ll arrive at your door.




Call Us: 1-978-452-2299
First Name:
Last Name:
Company:
Address:
Mail Stop:
City:
State (if in US):
Province/Region (if outside US):
Country:
ZIP (Postal) Code:
E-mail:
Telephone:
Fax:
Questions/Comments:
Verification: Please type:
Please have a Bomara Associates representative contact me


View Full Site View Mobile Optimized