 Server Technology Smart IP PDU's:

Smart IP PDU

Server Technology offers a wide range of CDUs (cabinet power distribution unit), also known as Power Distribution Units (PDU). The IP PDU provides reliable power distribution for high density applications while combining the precise True RMS metering capabilities of a metered PDU with the local and network monitoring of a Switch Rack PDU. Using the network interface, you can view power, temperature, and humidity level information via web browser, or receive SNMP based alarms when conditions exceed defined thresholds.


 
 The IP PDU can be remotely monitored, but cannot be remotely powered down

  This is ideal for Sarbanes Oxley and other testing compliance.

Model Number Description In/Out Voltage Outlets/Types Max Capacity

CS-12HD

Horizontal dual power input IP PDU with 12 outlets 208/208 (12) IEC 60320/C19 30A or 20A

CS-2HD1

Single Phase Sentry Smart Power Monitor for 120V Power Distribution 100/120 (2) IEC 60320/C19 Outlets 20A

CS-12HDE

European horizontal dual power input IP PDU with 12 outlets 230/230 (12) IEC 60320/C19 32A or 16A

CS-12HDD/Y

3 Phase (Delta/Wye) dual power input horizontal IP PDU with 12 outlets 208 (3 Phase)/208 (12) IEC 60320/C19 30A or 20A

CS-12VD/Y

3 Phase (Delta/Wye) horizontal IP PDU with 12 outlets 208 (3 Phase)/208 (12) IEC 60320/C19 60A

CS-16V

Vertical IP PDU with 16 outlets 208/208 or 120/120 (16) NEMA 5-20R or (16) IEC 60320/C13  30A or 20A

CS-16VE

European vertical IP PDU with 16 outlets 230/230 (16) NEMA 5-20R or (16) IEC 60320/C13  32A or 16A

CS-16V-MX

Vertical IP PDU with 16 outlets - No branch circuit protection 208/208 or 120/120 (16) NEMA 5-20R  20A

CS-16VE-MX

European vertical IP PDU with 16 outlets - No branch circuit protection 230/230 (16) NEMA 5-20R  16A

CS-18VD/Y (C13/C19)

3 Phase (Delta/Wye) vertical IP PDU with 18 mixed-type outlets 208 (3 Phase)/208 (12) IEC 60320/C19 & (6) IEC 60320/C13 60A

CS-2HD2/HDE

Single Phase Sentry Smart Power Monitor for 208 - 240V power distribution 208-240, 230 (2) IEC 60320/C19 Outlets 16A or 20A

CS-21VD/Y

3 Phase (Delta/Wye) vertical IP PDU with 21 outlets 208 (3 Phase)/208 (21) IEC 60320/C13 20A

CS-24V

Vertical IP PDU with 24 outlets 208/208 or 120/120 (24) NEMA 5-20R or (24) IEC 60320/C13 30A or 20A

CS-24VE

European IP PDU with 24 outlets 230/230 (24) NEMA 5-20R or (24) IEC 60320/C13 32A or 16A

CS-24V (C13/C19)

Vertical IP PDU with 24 mixed-type outlets 208/208 or 120/120 (18) IEC 60320/C13 & (6) IEC 60320/C19 30A or 20A

CS-24VE (C13/C19)

European IP PDU with 24 mixed-type outlets 230/230 (18) IEC 60320/C13 & (6) IEC 60320/C19 32A or 16A

CS-24VD/Y

3 Phase (Delta/Wye) vertical IP PDU with 24 outlets 208 (3 Phase)/208 (24) IEC 60320/C13 30A

CS-24VD/Y (C13/C19)

3 Phase (Delta/Wye) vertical IP PDU with 24 mixed-type outlets 208 (3 Phase)/208 (18) IEC 60320/C13 & (6) IEC 60320/C19 30A

CS-24V4

400V 3 Phase vertical IP PDU with 24 outlets 400 (3 Phase)/230 or 208 (3 Phase)/208 (24) IEC 60320/C13 32A or 16A

CS-24V4 (C13/C19)

400V 3 Phase vertical IP PDU with 24 mixed-type outlets 400 (3 Phase)/230 (18) IEC 60320/C13 & (6) IEC 60320/C19  32A or 16A

CS-27VY-MX (20A)

3 Phase (Wye) 20A vertical IP PDU with 27 outlets - No branch circuit protection 208 (3 Phase)/120 & 208 (21) IEC 60320/C13 & (6) NEMA 5-20R 20A

CS-27VY (30A)

3 Phase (Wye) 30A vertical IP PDU with 27 outlets 208 (3 Phase)/120 & 208 (21) IEC 60320/C13 & (6) NEMA 5-20R 30A

CS-3AVY

3 Phase (Wye) vertical IP PDU with 30 mixed-type outlets - 3 Outlet types 208 (3 Phase)/120 & 208 (12) NEMA 5-20R, (9) IEC 60320/C13, & (9) IEC 60320/C19 30A or 20A

CS-30V2/E

1 Phase Vertical IP PDU with 30 mixed-type outlets - 2 Outlet types 208/240, 230 (24) IEC 60320/C13
(6) IEC 60320/C19
16A, 20A, 30A or 32A

CS-36VD/Y

3 Phase (Delta/Wye) vertical IP PDU with 36 outlets 208 (3 Phase)/208 (36) IEC 60320/C13 30A

CS-36VD/Y (C13/C19)

3 Phase (Delta/Wye) vertical IP PDU with 36 mixed-type outlets 208 (3 Phase)/208 (24) IEC 60320/C13 & (12) IEC 60320/C19 60A

CS-48VD

Dual power input vertical IP PDU with 48 outlets 208/208 or 120/120 (48) NEMA 5-20R or (48) IEC 60320/C13 30A or 20A

CS-48VDE

European dual power input vertical IP PDU with 48 outlets 230/230 (48) NEMA 5-20R or (48) IEC 60320/C13 32A or 16A

CS-48VDD/Y

3 Phase (Delta/Wye) dual power input vertical IP PDU with 48 outlets 208 (3 Phase)/208 (48) IEC 60320/C13 30A or 20A

CS-54VDY

3 Phase (Wye) dual power input vertical IP PDU with 54 outlets 208 (3 Phase)/208 (12) NEMA 5-20R & (42) IEC 60320/C13 30A or 20A

CS-84VD

Dual input vertical IP PDU with 84 outlets 208/208 (84) IEC 60320/C13  30A or 20A

CS-84VDD/Y

3 Phase (Delta/Wye) dual input vertical IP PDU with 84 outlets 208 (3 Phase)/208 (84) IEC 60320/C13 30A or 20A



 IP PDU Features:

Easily replace fuses on your power monitoring PDU

Branch Circuit Protection

The Server Technology Sentry CDU Family meets the UL 60950-1 requirement for branch circuit protection.

Power monitoring PDUs have digital true RMS LED displays

Local and Network Input Current Monitoring

Exclusive Digital True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital display on the IP PDU enclosure reports the aggregate current draw of the branch circuit.

The monitoring information can also be accessed over IP using a web browser or SNMP alerts.

Attach environmental sensors to your power monitoring PDU

Temperature and Humidity

The IP PDU supports two external 10ft (3m) probes. Each of these probes measures both Temperature and humidity. Receive SNMP-based alerts or email notifications from your IP PDU when conditions exceed defined thresholds.

 

Zero U PDU

The IP PDU is available in a vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. They mount on the back rails or in the cavity space of the cabinet.

 

Add a redundant PDU

Connect an Expansion Cabinet power distribution unit to any IP PDU to monitor two power input circuits under 1 IP address.

 

SNMP Management & Event Notification

The IP PDU supports SNMP. This allows network management systems to use SNMP requests to retrieve information. The IP PDU includes SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension is also supported to provide network access power information. SNMP traps can be generated for various events.

 

Secure Access - SSH or SSL Protection

SSH is a Unix-based command interface and protocol for securely getting access to a network access device. The IP PDU support SSHv2. SSL is a commonly-used protocol for managing the security of a message transmission on the internet. The IP PDU supports SSLv3/TLSv1.

 

LDAP/LDAPS

The IP PDU supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enables authentication with LDAP servers. Administrators can pre-define and configure a set of necessary LDAP groups, and access rights for each group.

 

RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, console port access switch, or terminal server.


Server Technology Home
Bomara Homepage
Request Information

Bomara Associates Phone: 800.5BOMARA (800.526.6272) Phone: 978.452.2299 Fax: 978.452.1169 3 Courthouse Lane, Chelmsford, MA 01824 USA
Phone: 800.5BOMARA (800.526.6272)

Phone: 978.452.2299

 

Fax: 978.452.1169

Email: bobr@bomara.com     Web: www.bomara.com

3 Courthouse Lane, Chelmsford, MA 01824 USA
Serving the marketplace for over 40 years

© 2012 by Bomara. All rights reserved