Bomara Home » Server Technology Products » Power Monitoring PDU

 Server Technology Switched Outlet Power Monitoring PDU:



Power Monitoring PDU CS-12HD IP PDU
0U 1U 2U

  • Single Phase Ordering Info
  • 3 Phase Ordering Info
  • Description
  • Features
  • Discontinued



Single Phase Ordering Info for the Switched Outlet Power Monitoring PDU:


Model Number Description In/Out Voltage Outlets/Types Max Capacity
CWG-8H POPS power monitoring PDU with 8 C13 outlets. With C20 Input 208/240 (8) IEC 60320/C13 16A or 32A
CWG-8H1 POPS power monitoring PDU with 8 NEMA 5-20R outlets 100/120 (8) NEMA 5-20R 20A or 30A
CWG-8H2A413 Switched 1 Phase PDU 208VAC IEC C20 200-240V Inlet * Input, (8) C13 Output 208 (8) C13 20A
CWG-8H2C413 Switched 1 Phase PDU 208VAC L6-30P Input, (8) C13 Output 208 (8) C13 30A
CWG-8HEK413 Switched 1 Phase POPS PDU CWG-8H2/E 3.3kW - 7.3kW (8) C13 outlets 230 (8) C13 32A
CWG-16H POPS power monitoring PDU with 16 C13 outlets. 208/240 (16) IEC 60320/C13 16A or 32A
CWG-16H0A454 Switched 1 Phase PDU 208VAC C20 Input, (16) C13 Output 208 (16) C13 16
CWG-16H2A454 Switched 1 Phase PDU 208VAC C20 Input, (12) C13 & (4) C19 Output 208 (16) IEC C20 200-240V Inlet 20A
CWG-16H2C454 Switched 1 Phase PDU 208VAC L6-30P Input, (16) C13 Output 208 (16) NEMA L6-30P 30A
CWG-16HEA454 Switched 1 Phase PDU POPS CWG-16H2/E 3.3kW - 7.3kW (16) C13 outlets 230 (16) IEC C20 200-240V Inlet 16A
CWG-16HEK454 Switched 1 Phase PDU POPS CWG-16H2/E 3.3kW - 7.3kW (16) C13 outlets 230 (16) IEC 230V/32A 2P+PE 6Hr 32
CWG-16V Cabinet Power Distribution Unit with Per Outlet Power Sensing 208 (21)NEMA 5-20R
(6)NEMA L6-20R
20A or 30A
CWG‑16V2 POPS power monitoring PDU with 16 mixed-type outlets. 208/208 (12) IEC 60320/C13
(4) IEC 60320/C19
20A or 30A
CWG-16V2A317A1 Switched 1 phase PDU 208VAC C20 Input, (12) C13 & (4) C19 Output 208 (16) IEC C20 200-240V Inlet 20A
CWG-16V2C317A1 Switched 1 Phase PDU 208VAC L6-30P Input, (12) C13 & (4) C19 Output 208 (16) NEMA L6-30P 30A
CWG‑16VE European POPS power monitoring PDU with 16 mixed-type outlets. 230/230 (12) IEC 60320/C13
(4) IEC 60320/C19
16A or 32A
CWG-24V0A415C1 Switched 1 Phase PDU 208VAC C20 Input, (18) C13 & (6) C19 Output 208 (18) C13
(6) C19
16A
CWG‑24VE European POPS power monitoring PDU with 24 mixed-type outlets. 230/230 (18) IEC 60320/C13
(6) IEC 60320/C19
16A or 32A
CWG‑24V2 POPS power monitoring PDU with 24 mixed-type outlets. 208/208 (18) IEC 60320/C13
(6) IEC 60320/C19
20A or 30A
CWG-24V2/VE: 18xC13 & 6xC19 with PIPS Standard and European POPS power monitoring PDU with 24 mixed-type outlets. 208/240 (18) IEC 60320/C13
(6) IEC 60320/C19
16A or 32A
CWG-24V2/VE 24xC13 with PIPS PIPS (Per Inlet Power Sensing) and POPS (Per Outlet Power Sensing) 208-240V or 230V high density switched outlets 208-240, 230 (24) IEC 60320/C13 16A, 20A, 30A, 32A
CWG-24V2A417C1 Switched 1 phase PDU 208VAC IEC C20 200-240V Input, (18) C13 & (6) C19 Output 208 (18) C13 &
(6) C19
20A
CWG-24V5Z455A1 Switched 3 Phase PDU 415V L22-30P (4-Pole, 5-Wire Grounding) Input, (18) C13 & (6) C19 415 (18) C13
(6) C19
30A
CWG-24VDE417A1 Switched 3 phase PDU 208VAC L15-30P Input, (18) C13 & (6) C19 Output 208 (18) C13
(6) C19 Output
30
CWG-24VYM417C9 Switched 3 Phase PDU 208VAC L21-30P Input, (36) C13 & (12) C19 Output 208 (24) NEMA L21-30P 30A
STV-6107D Switched PDU 208VAC 3 Phase L15-20P (3 Pole, 4 Wire Grounding) Input, (18) C13 Output 208 (18) C13 20A
STV-6107E Switched 3 Phase PDU 208VAC L15-30P Input, (48) C13 Output 208 (48) C13 30A
STV-6107L Switched 3 Phase PDU 208VAC L21-30P Input, (18) C13 Output 208 (18) C13 30A
STV-6107M Switched 3 Phase PDU 208VAC L21-30P Input, (18) C13 Output 208 (18) C13 30A
STV-6304E Switched 3 phase PDU 240/415V Wye 60A IEC 60309 3P+N+G 6Hr Input, (36) C13 & (12) C19 Output 415 (36) C13 &
(12) C19 Output
60A
STV-6304J Switched 3 Phase PDU 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr Input, (36) C13 & (12) C19 Output 400 (48) 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr 16A
STV-6304K Switched 3 Phase PDU 400VAC 60309 Input, (36) C13 & (12) C19 Output 400 (48) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr 32A
STV-6501C Switched 1 Phase PDU 208VAC L6-30P Input, (24) C13 & (6) C19 Output 208 (30) NEMA L6-30P 30A
STV-6501K Switched 1 Phase PDU 230VAC IEC 230V/32A 2P+PE 6Hr Input, (24) C13 & (6) C19 Output 230 (30) IEC 230V/32A 2P+PE 6Hr 32A
STV-6501G Switched 1 Phase PDU 208VAC C20 Input, (24) C13 & (6) C19 Output 208 (24) C13
(6) C19
20A
STV-6502E Switched 3 Phase PDU 208VAC L15-30P Input, (24) C13 & (6) C19 Output 208 (30) NEMA L15-30P 30A
STV-6502L Switched 3 Phase PDU 208VAC L21-20P Input, (24) C13 & (6) C19 Output 208 (30) NEMA L15-30P 30A
STV-6502M Switched 3 Phase PDU 208VAC L21-30P Input, (24) C13 & (6) C19 Output 208 (24) C13 &
(6) C19 Output
30A
STV-6503D Switched 3 Phase PDU 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Input, (24) C13 & (6) C19 Output 415 (24) C13
(6) C19
30A
STV-6503K Switched 3 Phase PDU 230/400VAC Wye 32A IEC 60309 3P+N+PE 6Hr Input, (24) C13 & (6) C19 Output 400 (24) C13
(6) C19
32A
STV-6503J Switched 3 Phase PDU 230/400VAC Wye 16A IEC 60309 3P+N+PE 6Hr Input, (24) C13 & (6) C19 Output 400 (24) C13
(6) C19
16A
STV-6503Z Switched 3 Phase PDU 415VAC L22-30P Input, (24) C13 & (6) C19 Output 415 (24) C13
(6) C19
30A
STV-6506D Switched PDU 208VAC 3 Phase Delta 60A IEC 60309 3P+G 9Hr Input, (18) C13 & (12) C19 Output

208

(18) C13
(12) C19
60A
STV-6506V Switched 3 Phase PDU 208VAC CS8365 Input, (18) C13 & (12) C19 Output 208 (18) C13
(12) C19
50A
STV-6506Y Switched 3 Phase PDU 208V Wye 60A IEC 60309 3P+N+G 9Hr Input, (18) C13 & (12) C19 208

(18) C13
(12) C19

60A
STV-6508D Switched 3 Phase PDU 208VAC L15-20P Input, (30) C13 & (6) C19 Output 208 (30) C13
(6) C19
20A
STV-6508E Switched 3 Phase PDU 208VAC L15-30P Input, (30) C13 & (6) C19 Output 208 (30) C13
(6) C19
30A
STV-6508L Switched 3 Phase PDU 208V L21-20P (4P, 5W, Locking Plug) Input, (30) C13 & (6) C19 Output 208 (30) C13
(6) C19
20A
STV-6508M Switched 3 Phase PDU 208VAC L21-20P Input, (30) C13 & (6) C19 Output 208 (30) C13
(6) C19
30A
STV-6509A Switched 3 Phase PDU 415VAC L22-20P Input, (30) C13 & (6) C19 Output 415 (30) C13
(6) C19
20A
STV-6509C Switched 3 Phase PDU 240/415VAC Wye 20A IEC 60309 3P+N+G 6Hr Input, (30) C13 & (6) C19 Output 415 (30) C13
(6) C19
20A
STV-6509D Switched 3 Phase PDU 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Input, (30) C13 & (6) C19 Output 415 (30) C13
(6) C19
30A
STV-6509J Switched 3 Phase PDU 230/400VAC Wye 16A IEC 60309 3P+N+PE 6Hr Input, (30) C13 & (6) C19 Output 400 (30) C13
(6) C19 Output
16A
STV-6509K Switched 3 Phase PDU 230/400VAC Wye 32A IEC 60309 3P+N+PE 6Hr Input, (30) C13 & (6) C19 Output 400 (30) C13
(6) C19
32A
STV-6509Z Switched 3 Phase PDU 208VAC L22-30P Input, (30) C13 & (6) C19 Output 415 (30) C13
(6) C19
30A
STV-6521D Switched 3 Phase PDU 208VAC Delta 60A IEC 60309 3P+G 9Hr Input, (48) C13 Output 208 (48) C13 60A
STV-6521V Switched 3 Phase PDU 208VAC CS8365 Input, (48) C13 Output 208 (48) C13 50A
STV-6521Y Switched 3 Phase PDU 208VAC Wye 60A IEC 60309 3P+N+G 9Hr Input, (48) C13 Output 208 (48) C13 60A
STV-6525E Switched 3 phase PDU 240/415V Wye 60A IEC 60309 3P+N+G 6Hr Input, (36) C13 & (12) C19 Output 415 (36) C13
(12) C19
60A
 
Legacy Units
Model Number Description Input Voltage Outlets/Types Max Capacity
CWG-16H1 POPS power monitoring PDU with 16 NEMA 5-20R outlets 100/120 (16) NEMA 5-20R 20A or 30A
CWG-24V1 120V vertical power distribution with Per Outlet Power Sensing and Per Inlet Power Sensing 100-120 (24) NEMA 5-20R 20A or 30A


*PIPS - (Per Input Power Sensing) Active Power, Apparent Power, Energy k-Wh, Power Capacity, Reactance, and Power Capacity Used using the network interface. See the aggregate current draw, in Amps, locally using the onboard LED.



3 Phase Ordering Info for the Switched Zero U Outlet Power Monitoring PDU:


Model Number Description Input Voltage Outlets/Types Max Capacity
CWG-24VD/Y 208-240V 3 phase Delta or Wye POPS power monitoring PDU with 24 mixed-type outlets. 208-240 3-phase Delta or Wye, 50/60  Hz (18) IEC 60320/C13
(6) IEC 60320/C19
20A or 30A
CWG-24VD/VY: 3 phase 20/30A 18xC13 & 6xC19 with PIPS Three Phase Per Outlet Power Sensing and Per Inlet Power Sensing for Overhead Power 208 or 240 (18) IEC 60320/C13
(6) IEC 60320/C19
20A or 30A
CWG-24VD/VY: 3 phase 50/60A 12xC13 & 12xC19 with PIPS 3 Phase Per Outlet and Per Inlet Power Sensing with Twelve C19 for Blade Server installations 208V or 240V (12) IEC 60320/C13
(12) IEC 60320/C19
50A or 60A
CWG-24VD/VY: 50/60A 3Ph Busway 18xC13 & 6xC19 240V, 3-phase Delta or Wye POPS power monitoring PDU with 24 mixed-type outlets. 240V, 3-phase Delta or Wye,
50/60  Hz

(18) IEC 60320/C13 (6) IEC 60320/C19 50A or 60A
CWG-24V4 400V 3Ph 16/32A Busway 18xC13 & 6xC19 with PIPS* 230/400V 3-Phase Wye POPS power monitoring PDU with 24 mixed-type outlet with PIPS* 230/400V 3-Phase Wye,
50/60Hz

(18) IEC 60320/C13 (6) IEC 60320/C19

16A or 32A
CWG-24V4 400V 3Ph 16/32A Busway 12xC13 & 12xC19 with PIPS* 230/400V 3-Phase Wye POPS power monitoring PDU with 24 mixed-type outlets with PIPS* 230/400V 3-Phase Wye,
50/60Hz
(12) IEC 60320/C13 (12) IEC 60320/C19
16A or 32A
CWG-24V5 415V 3Ph 20/30A 18xC19 & 6xC19 240V/415V 3-Phase Wye POPS power monitoring PDU with 24 mixed-type outlets. 3Ph Wye 240V/415V
50/60Hz
(18) IEC 60320/C13 (6) 60320/C19
20A or 30A
CWG-24V5 415V 3Ph 20/30A Busway 18xC13 & 6xC19 with PIPS* 240V/415V 3-Phase Wye POPS power monitoring PDU with 24 mixed-type outlets with PIPS* 240/415V 3-Phase Wye,
50/60Hz
(18) IEC 60320/C13 (6) IEC 60320/C19
20A or 30A
CWG-24V5 415V 3Ph 20/30A Busway 12xC13 & 12xC19 with PIPS* 240V/415V 3-Phase Wye POPS power monitoring PDU with 24 mixed-type outlets with PIPS* 240/415V 3-Phase Wye,
50/60Hz
(12) IEC 60320/C13 (12) IEC 60320/C19
20A or 30A
CWG-30VD/VY 3Ph 20/30A Busway 24xC13 & 6xC19 with PIPS* 240V 3-Phase Delta or Wye POPS power monitoring PDU with 30 mixed-type outlets with PIPS* 240V, 3-phase Delta or Wye,
50/60Hz
(24) IEC 60320/C13 (6) IEC 60320/C19
20A or 30A
CWG-30VD/VY 3Ph 20/30A Busway with PIPS* 240V 3-Phase Delta or Wye POPS power monitoring PDU with 30 outlets with PIPS* 240V, 3-phase Delta or Wye,
50/60Hz
(30) IEC 60320/C13
20A or 30A
CWG-48VD/VY 3Ph 20/30A with PIPS* 208V 3-Phase Delta or Wye POPS power monitoring PDU with 48 outlets with PIPS* 208V, 3-Phase Delta or Wye,
50/60Hz
(48) IEC 60320/C13
20A or 30A
CWG‑24V4 European 400 3 phase / 230 VAC POPS power monitoring PDU with 24 mixed-type outlets. 400 3-phase / 230 (18) IEC 60320/C13
(6) IEC 60320/C19
32A


*PIPS - (Per Input Power Sensing) Active Power, Apparent Power, Energy k-Wh, Power Capacity, Reactance, and Power Capacity Used using the network interface. See the aggregate current draw, in Amps, locally using the onboard LED.



Description for the Switched Zero U Outlet Power Monitoring PDU:


Server Technology offers a wide range of CDUs (cabinet power distribution unit). The switched Per Outlet Power Sensing. (POPS) monitoring PDU combines network configuration and management with power distribution, environmental monitoring, and the ability to provide power monitoring for individual outlets/devices. Power information per outlet includes:

  • Current
  • Voltage
  • Power (kW)
  • Apparent power (VA)
  • Crest factor
  • Power factor

Remotely reboot a single or dual-power server with one command. The power monitoring PDU can also be configured to send SNMP or email-based alerts when power or environmental conditions exceed thresholds, and assign user specific access rights to designated outlets or groups.

Utilizing the grouping feature, power information is available per device (multiple outlets), groups of devices (applications), individual power monitoring PDU, cabinet, rows of cabinets, or the whole data center floor. Combining the switched power monitoring PDU with Server Technology's Sentry Power Manager software tool, you can cluster outlets and gain power usage information across multiple power monitoring PDU's individual IP address.

The switched power monitoring PDU has top entry for network, serial, and environmental connections combined with a bottom power cord entry. Current monitors are easily inverted via the web GUI or serial interface. This provides flexibility when connecting power a monitoring PDU to overhead power or busways.




Features for the Switched Zero U Outlet Power Monitoring PDU:


Per Outlet Power Monitoring PDU

POPS (Per Outlet Power Sensing)

Monitor Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor and Power Factor per outlet at an accuracy of +/- 2%

Easily replace fuses on your power monitoring PDU

Fuse Retractors for Branch Circuit Protection

These tool-less retractors pull out for easy access and replacement of fuses. The Server Technology Sentry CDU Family meets the UL 60950-1 requirement for branch circuit protection.

Power monitoring PDUs have digital true RMS LED displays

Input Current Monitoring

Exclusive Digital True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital display on the power monitoring PDU enclosure reports the aggregate current draw of the branch circuit.

Attach environmental sensors to your power monitoring PDU

Temperature and Humidity

The switched power monitoring PDU supports two external 10ft (3m) probes. Each of these probes measures both Temperature and humidity. Receive SNMP-based alerts or email notifications from your power monitoring PDU when conditions exceed defined thresholds.

Pops Pips

PIPS - Per Input Power Sensing

Accurately measures active power, apparent power, energy k-wh, power capacity, reactance, and power capacity used using the network interface. See the aggregate current draw, in Amps, locally using the onboard LED.
 

Zero U PDU

The power monitoring PDU has a vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. They mount on the back rails or in the cavity space of the cabinet.

 

Add a redundant PDU

Connect an Expansion Cabinet power distribution unit to any POPS power monitoring PDU to control two power input circuits and manage outlets (individual or groups) under 1 IP address.

 

Network Access and Per Outlet Control

Individual or group outlet network access power control to cycle power and reboot any selected servers or other network devices. Use TCP/IP (HTTP, HTTPS, SSH, Telnet, SNMP) or RS-232 to communicate with each power monitoring PDU and rectify locked-up network devices. Reduce Mean Time to Repair (MTTR) a failing server by controlling individual power outlet receptacles to reboot any selected server or other device.

The POPS power monitoring PDU can also be controlled on a per outlet basis. Assign outlets to a group for control of dual-power supply servers and other gear with a single command. Create an unlimited number of groups with any combination of outlets associated to each group.

 

SNMP Management & Event Notification

The POPS power monitoring PDU supports SNMP. This allows network management systems to use SNMP requests to retrieve information and control power for the individual outlets. The power monitoring PDU includes SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension is also supported to provide network access power control. SNMP traps can be generated for various events.

 

Secure Access - SSH or SSL Protection

SSH is a Unix-based command interface and protocol for securely getting access to a network access device. The power monitoring PDU support SSHv2. SSL is a commonly-used protocol for managing the security of a message transmission on the internet. The power monitoring PDU supports SSLv3/TLSv1.

 

LDAP/LDAPS

The power monitoring PDU supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enables authentication with LDAP servers. Administrators can pre-define and configure a set of necessary LDAP groups, and access rights for each group.

 

RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, console port access switch, or terminal server.




Discontinued Models:


Model Number Description
CWG-24V54458/ML Switched POPS CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye 30A, IEC 60309 (3P+N+PE) 6hr Red Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers, ****CUSTOM BOM****
CWG-24VDX454A1/Z0 Switched POPS CDU, 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 60A, Watertight IEC 60309 9hr 4Pin Blue Plug, User specified cord length (3' to 15'), Top Power Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers
CWG-8H1A113 Switched POPS CDU, Per Outlet Power Sensing, PIPS (Per Inlet Power Sensing), 1U, 8 x NEMA 5-20P Outlets, Input Amp Meter, 120V 20A w/ IEC 60320 C20 Inlet, 2 x Temp/Humid Capable, No Branch Circuit Protection (input power cord ordered separately)
CXG-24V54458/ML Switched POPS CDU (Expansion Unit), PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye 30A, IEC 60309 (3P+N+PE) 6hr Red Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers, 7 in. Link Cable, Custom BOM
CXG-24VDX454A1/Z0 Switched POPS CDU (Expansion Unit), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 60A, IEC 60309 Watertight IP67 9hr 4Pin Blue Plug, User specified cord length (3' to 15'), Top Power Cord Entry, Middle Display/Network, Circuit Breakers
CXG-8H1A113 Switched POPS CDU (Expansion Unit), Per Outlet Power Sensing, PIPS (Per Inlet Power Sensing), 1U, 8 x NEMA 5-20P Outlets, Input Amp Meter, 120V 20A w/ IEC 60320 C20 Inlet, No Branch Circuit Protection (input power cord ordered separately)



Call Us: 1-978-452-2299
First Name:
Last Name:
Company:
Address:
Mail Stop:
City:
State (if in US):
Province/Region (if outside US):
Country:
ZIP (Postal) Code:
E-mail:
Telephone:
Fax:
Questions/Comments:
Verification: Please type:
Please have a Bomara Associates representative contact me


View Full Site View Mobile Optimized