 Server Technology Switch PDU Series:



Switch Rack PDU


Description:

The switch PDU combines remote configuration and management with power distribution as well as power and environmental monitoring. Remote reboot a single or dual-power server with one command. Receive SNMP alerts from your switch PDU when power or environmental conditions exceed thresholds. You can also assign users specific access rights to designated outlets or groups.

The switch PDU allows you to power cycle individual power outlets or groups of power outlets, to remotely reboot servers and network devices, or remotely power off unused receptacles from anywhere in the world.

Only the switch PDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amp / high voltage, UL 60950-1 branch circuit protection, SSL & SSH security, and SNMP-based input current monitoring.



  • Single Phase
  • 3 Phase
  • Features



Ordering Information for the Single Phase Switch PDU Series:


Model Number Description In/Out Voltage Outlets/Types Max Capacity
C1W08HC-0A002BAC Requires PTCORD-L1, -L2, -L3, -L4, -L5, -L6, or –L7 208V (8) x IEC 60320/C13 3.3 kW
C1W08HC-0ABA2BAC Switched PRO1, 1U, 8 x IEC C13 Outlets, Input Amp Meter, 120/208-240 20A and 230V 16A Rating w/ IEC C20 In 120/208-240V 8 x IEC C13 Outlets 3.3 kW
C1W08HC-1A002BA5 Single Phase 120V, C20 Input, 1U Rack, 1.9 kW, Switched PDU 120V (8) x NEMA 5-20R 1.9kW
C1W08HC-1ACA2BA5 Switched PRO1, PIPS (Per Inlet Power Sensing), 1U, 8 x NEMA 5-20P Outlets, Input Amp Meter, 120V 20A w/ IEC 60320 C20 Inlet, 2 x Temp/Humid Capable, Circuit Breakers (input power cord ordered separately) 120V 8 x NEMA 5-20P Outlets 1.9 kW
C1W08HC-1CCA2BA5 Single Phase 120V, L5-20P Input, 1U Rack, 1.9kW, Switched PDU 120V (8) x NEMA 5-20R 1.9kW
C1W08HC-1DCA2BA5 Switched PRO1, PIPS (Per Inlet Power Sensing), 1U, 8 x NEMA 5-20P Outlets, Input Amp Meter, 120V 30A w/ NEMA L5-30P Plug, 10 ft (3m) cord, 2 x Temp/Humid Capable, Circuit Breakers 120V 8 x NEMA 5-20P Outlets 2.8 kW
C1W08HC-2CBA2BAC PRO1 Switched PDU, 208V NEMA L6-30P Input, (8) x IEC 60320/C13 Output 208V (8) x IEC 60320/C13 5.0 kW
C1W08HC-EPBA2BAC C1W08HC-EPBA2BAC 230V (8) x IEC 60320/C13 7.3 kW
C1W16VS-0AFA17AC Switched PRO1, PIPS (Per Input Power Sensing), 0U, 16 x IEC C13 Outlets, LED amp meter, 120-240V C20 input 120-240V 16 x IEC C13 Outlets 3.3 kW
C1W16VS-1AFA17A5 Switched PRO1, 0U, 16 x NEMA 5-20R Outlets, LED amp meter, 120V 20A input w/ C20 Inlet, (2) Temperature/Humidity Sensor Capable 120V 16 x NEMA 5-20R 1.9 kW
C1W16VS-1CFA17A5 Single Phase 120VAC, L5-20P Input, 0U, 1.9kW, Switched PDU 120V (16) x NEMA 5-20R 1.9kW
C1W16VS-1DFA17A5 Switched PRO1, 0U, 16 x NEMA 5-20R Outlets, LED amp meter, 120V 30A input w/ L5-30P connector & cord, 10ft (3m) 120V 16 x NEMA 5-20R 2.8 kW
C1W16VS-2CFA17AC Switched PRO1, PIPS (Per Input Power Sensing), 0U, 16 x IEC C13 Outlets, LED amp meter, 208V 30A input w/ L6-30P 208V 16 x IEC C13 Outlets 5.0 kW
C1W16VS-EPFA17AC C1W16VS-EPFA17AC 230V (16) x IEC 60320/C13 7.3 kW
C1W16VS-OAFA17AC Requires PTCORD-L1, -L2, -L3, -L4, -L5, -L6, or –L7 230V (16) x IEC C20 3.6 kW
CW-16H Reboot a single or dual-power server with one command. 208V or 230V (16) IEC 60320/C13 16A, 20A, 30A or 32A
CW-16H2/E Horizontal switch 2U rack pdu with 16 outlets 208-240V, 230V (16) IEC 60320/C13 16A, 20A, 30A or 32A
CW-16HD1 Horizontal 2U Dual Infeed CDU with remote outlets control and PIPS Measurement Technology 100-120V (16) NEMA 5-20R 20A or 30A
CW-16V1 PIPS (Per Inlet Power Sensing) for 120VAC with switched outlet power control via IP for remote monitoring and management. 100-120V (16) NEMA 5-20R 20A or 30A
CW-16V1 Fuses Reboot a single or dual-power server with one command. 100-120V (16) NEMA 5-20R 20A or 30A
CW-16V1F317 Switched 1 Phase PDU 120VAC L5-20P Input, (16) 5-20R 120VAC (16) 5-20R 20A
CW-16V1P317 Switched CDU with PIPS, 0U, 16 x NEMA 5-20R Outlets, LED amp meter, 120V 20A input w/ 5-20P connector & cord, 9.5 ft (2.89 m), (2) Temperature/Humidity Sensor Capable, with retractable fuses 120V (16) 5-20R 20A
CW-16V2 Fuses with PIPS* Reboot a single or dual-power server with one command. 208-240V or 230V (16) IEC 60320/C13 16A, 20A, 30A or 32A
CW-16V2 with Fuses Reboot a single or dual-power server with one command. 208-240V (16) IEC 60320/C13 20A or 30A
CW-16VE-MX European vertical switch rack pdu with 16 outlets - No branch circuit protection 230/230 (16) NEMA 5-20R or (16) IEC 60320/C16 16A
CW-24V1 Vertical switch rack pdu with 24 outlets 100/120V (24) NEMA 5-20R 20A or 30A
CW-24V2 Vertical switch rack pdu with 24 outlets 208/208 (24) IEC 60320/C13 30A or 20A
CW-24V2 (C13/C19) Vertical switch rack pdu with 24 mixed-type outlets 208/208 (18) IEC 60320/C13 & (6) IEC 60320/C19 30A or 20A
CW-24V2/E PIPS (Per Inlet Power Sensing) and switched outlet power control via IP with remote monitoring and management. 230, 208-240 (24) IEC 60320/C13 16A, 20A, 30A or 32A
CW-24V2/VE Vertical switch rack PDU with 24 outlets and busway with PIPS 208/240V, 230V (18) IEC 60320/C13
(6) IEC 60320/C19
16A, 20A, 30A or 32A
CW-24V2/VE with PIPS Reboot a single or dual-power server with one command. 208-240V or 230V (24) IEC 60320/C13 16A, 20A, 30A or 32A
CW-24VE European vertical switch rack pdu with 24 outlets 230/230 (24) IEC 60320/C14 23A or 16A
CW-24VE (C13/C19) European vertical switch rack pdu with 24 mixed-type outlets 230/230 (18) IEC 60320/C13 & (6) IEC 60320/C20 32A or 16A
CW-32VD2/E Dual Single Phase infeed, Switched Power Control via IP, 32 C13/C19 outlets. 230, 208-240 (24) IEC 60320/C13
(6) IEC 60320/C19
16A, 20A, 30A or 32A
CW-32VDE European dual input vertical switch rack pdu with 32 outlets 230/230 (32) NEMA 5-20R or 16A
STV-4101B Switched 1 Phase PDU 120VAC L6-20P Input, (18) c13 & (6) C19 120VAC (18) c13 & (6) C19 20A
STV-4101C Switched 1 Phase PDU 208VAC L6-30P Input, (18) c13 & (6) C19 208VAC (18) c13 & (6) C19 30A
STV-4101G Switched 1 Phase PDU 208VAC IEC C20 100-240V Inlet Input, (18) c13 & (6) C19 208VAC (18) c13 & (6) C19 20A
STV-4102 Switched PIPS 1-Phase 208-240V power distribution with flexible installation using the Power Pivot inlet and Auto-flip LED display. 208/240V or 230V Single Phase high-density. 230, 208-240 (24) IEC 60320/C13 30A or 32A
STV-4102G Switched 1 Phase PDU 208VAC IEC C20 100-240V Inlet * Input, (24) c13 208VAC (24) c13 20A
STV-4301 Unique high density 48 outlet Switched CDU for low power server applications 230, 208-240 (48) IEC 60320/C13 16A, 20A, 30A or 32A
STV-4541 PRO1 Switched STV-4541 208/208V or 230/230V (18) C13 & (6) C19 outlets 3.3kW - 7.3kW
STV-4540 PRO1 Switched STV-4540 208/208V or 230/230V (24) C13 outlets 5.7kW - 8.6kW
Sentry PT22 Allows dual power equipment to be rebooted by a single source via web, SNMP, or dial up connection, or RS-232 120Vor 208V (4)  IEC 60320/C19 20A
Discontinued Units
Model Number Description In/Out Voltage Outlets/Types Max Capacity
CW-16H1B454E7
Replaced by C1W16HR-1DAA5BE7

CX-16H1B454E7
Replaced by C1X16HR-1DAA5BE7
Switched PDU, Per Input Power Sensing, 2U, 16 x IEC C13 Outlets, Input Amp Meter, 120V 30A w/ NEMA L5-30P Connector, 3m (10ft) Cord (Front Cord Entry), 20 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable 120VAC (16) IEC 60320/C13 30A
CW-16H0A454
Replaced by C1W16HR-0AAA5BAC

CX-16H0A454
Replaced by C1X16HR-0AAA5BAC
Switched PDU (Expansion Unit), Per Input Power Sensing2U, 16 x IEC C13 Outlets, Input Amp Meter, 120-240V 20A w/ IEC C20 Inlet (Front Cord Entry), 20 A Circuit Breakers, (Input power cord sold separately) 120-240VAC (16) IEC 60320/C13 20A
CW-16H1
Discontinued
Horizontal switch 2U rack pdu with 16 outlets 100/120V (16) NEMA 5-20R 20A or 30A
CW-24V2C313A1
Discontinued
Switched CDU, 0U, 18 x IEC C13 Outlets and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 30A input w/ L6-30P connector and cord, Bottom/Bottom Cord Entry, 3m (10') Cord, 2 x Temp/Humid Capable, Retractable Fuses
CW-24V2G311A1
Discontinued
Switched CDU, 0U, 18 x IEC C13 Outlets and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 30A input w/ L6-20P connector and cord, Bottom/Front Cord Entry, 3m (10') Cord, (2) Temperature/Humidity Sensor Capable, Retractable Fuses



Ordering Information for the 3 Phase Switch PDU Series:



Model Number Description In/Out Voltage Outlets/Types Max Capacity
48DCW-4X125-01 -48VDC Switched (4) 125A inputs (4) 125A outputs -48 VDC In
-48 VDC Out
(4) 125A inputs (4) 125A outputs 24 kW
C1W24VS PRO1™ Switched C1W24VS 208/208V (18) C13 & (6) C19 outlets 5.7kW - 8.6kW
C1W24VS-DBFA13A1 3 Phase, 208VAC, Delta, 0U, 5.7kW, L15-20P In, (18) C13 / (6) C19 Out, Switched PDU 208V Delta (18) x IEC 60320/C13
(6) x IEC 60320/C19
5.7kW
C1W24VS-DCFA13A1 3 Phase, 208VAC, Delta, 0U, 8.6kW, L15-30P In, (18) C13 / (6) C19 Out, Switched PDU 208V Delta (18) x IEC 60320/C13
(6) x IEC 60320/C19
8.6kW
C1W24VS-DCFA13AC 3 Phase, Delta, 208V, 0U, 8.6kW, L15-30P In, (24) C13 Out, Switched PDU 208V Delta (24) x IEC 60320/C13 8.6kW
C1W24VS-YBFA13C9 3 Phase, 208VAC, Wye, 0U, 5.7kW, L21-20P In, (18) C13 / (6) C19 / (1) 5-20R Out, Switched PDU 208V Wye (18) x IEC 60320/C13
(6) x IEC 60320/C19
(1) x NEMA 5-20R
5.7kW
C1W24VS-YCFA11C9 3 Phase, 208VAC, Wye, 0U, 8.6kW, L21-30P In, (18) C13 / (6) C19 / (1) 5-20R Out, Switched PDU 208V Wye (18) x IEC 60320/C13
(6) x IEC 60320/C19
(1) x NEMA 5-20R
8.6kW
C1W24VT 3 Phase PRO1 Switched C1W24VT 230/400V or 240/415V (24) C13 outlets 11.1kW - 22.0kW
CW-16V Vertical switch rack pdu with 16 outlets 208/208 or 120/120 (16) NEMA 5-20R or (16) IEC 60320/C13 30A or 20A
CW-24VY 3 Phase (Delta/Wye) vertical switch rack pdu with 24 mixed-type outlets for overhead busway power 208 (3 phase)/208 or 208 (3 phase)/120 & 208 (18) IEC 60320/C13 & (6) IEC 60320/C20 30A
CW-48V4 3 Phase (Wye) vertical switch rack pdu with 48 outlets 230/400V (3 phase) (36) IEC 60320 C13 (12) IEC 60320 C19 32A or 16A
CW-48VD/VY 3-Phase PIPS Per Inlet Power Sensing for 50/60A power in 2U high density, mixed outlet configuration 208/240 (3 Phase) (36) IEC 60320/C13
(12) IEC 60320/C19
50A or 60A
CW-48VD/VY 3-Phase PIPS Per Inlet Power Sensing for 50/60A power in 2U high density, mixed outlet configuration 208/240 (3 Phase) (36) IEC 60320/C13
(12) IEC 60320/C19
50A or 60A
STV-4526 PRO2™ Switched STV-4526 208/208V (36) C13 and (12) C19 outlets 14.4kW - 17.3kW
STV-4522D 3-Phase Delta (L-L), NEMA L15-20P Input 208/208V (48) IEC C13 outlets 5.7kW
STV-4522E 3-Phase Delta (L-L), NEMA L15-30P Input 208/208V (48) IEC C13 outlets 8.6kW
STV-4522L 3-Phase Wye (L-L), NEMA L21-20P Input 208/208V (48) IEC C13 outlets 5.7kW
STV-4522M 3-Phase Wye (L-L), NEMA L21-30P Input 208/208V (48) IEC C13 outlets 8.6kW
STV-4522V 3-Phase Delta (L-L), CS8365 3P+G 50A Input 208/208V (48) IEC C13 outlets 10.0kW
Discontinued Units
Model Number Description In/Out Voltage Outlets/Types Max Capacity
CW-24V4
400V vertical switch rack pdu with 24 mixed-type outlets C13, C19, and/or C20 400 (3 phase)/230 32A or 16A
CW-24V5
Vertical switch rack pdu with 24 mixed-type outlets C13 and/or C19 240/415V (3 phase) 30A or 20A
CW-24VD/VY
3 Phase (Delta/Wye) vertical switch rack pdu with 24 mixed-type outlets. C13 and/or C19 208, 240 (3 Phase) 20A, 30A, 50A, or 60A
CW-24VD/VY/VA
3 Phase (Delta/Wye) vertical switch pdu with 24 mixed-type outlets L15-30P or L21-30P 208-240V (3 phase) 20A, 30A, or 35A
CW-16HD2/E Horizontal 2U Dual Infeed CDU with remote outlets control and PIPS Measurement Technology 208-240V, 230V (16) IEC 60320/C13 16A, 20A, 30A or 32A
CW-16V-MX Vertical switch rack pdu with 16 outlets - No branch circuit protection 208/208 or 120/120 (16) NEMA 5-20R or (16) IEC 60320/C15 20A or 30A
CW-16VE European vertical switch rack pdu with 16 outlets 230/230 (16) NEMA 5-20R or (16) IEC 60320/C14 32A or 16A
CW-24V 3-Phase single or dual-power Cabinet Power Distribution Unit with Outlet Control 208 (3 Phase) (18) IEC 60320/C13
(6) IEC 60320/C19
20A or 30A
CW-24V1P325 Switched PDU with PIPS (Per Input Power Sensing), 0U, 24 x NEMA 5-20R Outlets, (1) Input LED Amp Meter in the middle of the unit, 120V NEMA 5-20P Inlet, 9ft cord Bottom/Front Cord Entry, (2) Temp/Humidity Sensor Capable, Fuses (Power Cord Sold Separately) 120V (24) 5-20R --
CW-24V5 415V 3Ph 20/30A 18xC13 & 6xC19 with PIPS*
Vertical switch rack pdu with 24 mixed-type outlets 240V/415V (3 phase) (18) IEC 60320/C13 (6) IEC 60320/C19 30A or 20A
CW-24V5: 240/415V 3 phase 20/30A 12xC13 & 12xC19 Busway with PIPS
3-Phase Switched PIPS - Per Inlet Power Sensing, Power distribution with LED current displays and IP monitoring, 240/415V high density for busway installations. 240/415V (3 Phase) (12) IEC 60320/C13
(12) IEC 60320/C19
20A or 30A
CW-2H IPM-2 Switched simple PDU with 2 outlets 208/208 or 120/120 (2) NEMA L5-20R or (2) IEC 60320/C13 16A
CW-30V5 3-Phase Switched PIPS - Per Inlet Power Sensing with 30 mixed outlets for high density installations with 240/415V power distribution 240/415V (3 Phase) (24) IEC 60320/C13
(6) IEC 60320/C19
20A or 30A
CW-30VD/VY Vertical switch rack pdu with 30 mixed-type outlets 208V (3 phase) (24) IEC 60320/C13 (6) IEC 60320/C19 30A or 20A
CW-30VD/Y: 3-Phase 20/30A (24) C13 & (6) C19 Busway
3-Phase Switched 208-240V Power Distribution for overhead busway applications. 208 or 240 (3 Phase) (24) IEC 60320/C13
(6) IEC 60320/C19
30A or 20A
CW-32VD Dual input vertical switch rack pdu with 32 outlets 208/208 or 120/120 (32) NEMA 5-20R or (32) IEC 60320/C13 30A or 20A
CW-48V5 3 Phase (Wye) vertical switch rack pdu with 48 outlets 240/415V (3 phase) (36) IEC 60320 C13 (12) IEC 60320 C19 30A or 20A
CW-48VD/VY 50/60A 3Ph
3 Phase (Delta/Wye) vertical switch rack pdu with 48 outlets 208V (3 phase) (48) IEC 60320/C13 50A or 60A
CW-48VD/Y 3 Phase (Delta/Wye) vertical switch rack pdu with 48 outlets 208 (3 phase)/208 (48) IEC 60320/C13 30A or 20A
CX-24VYM311A1/TH Switched CDU (Expansion Unit), 0U, 18 x IEC C13 & 6 x IEC C19, 1 x NEMA 5-20R Utility Outlets, 3 x LED Amp Meters, 3-phase Wye, 30A w/ NEMA L21-30P cord set, 10ft (3m), Bottom/front entry, w/ Retractable Fuses, (2) Temperature/Humidity Sensors Capable -- (18) IEC 60320/C13 (6) IEC 60320/C19 30A
Dual-Feed PTXL/PTXM-HD16 Single point of reboot for dual or redundant power supplies. It combines intelligent power distribution, remote management, power monitoring and environmental monitoring. 100-120V or 208-240V or 230V

(16) NEMA 5-20R or
(16) IEC 60320/C13

16A, 20A, 30A or 32A
Power Tower XL - Power Tower XM PTXL is a secure, reliable and high-speed method for rebooting individual or groups of servers — deployed and verified by Fortune 100 enterprises, service providers, universities and government agencies 100-120V or 208-240V (16) NEMA 5-20R 20A or 30A
SEV-4103Y Switched 3 Phase PDU 208VAC Wye 60A IEC 60309 3P+N+G 9Hr IP44 Input, (24) c13 208VAC (24) c13 60A
STV-4103D Switched 3 Phase Delta PDU 208V Delta 60A IEC 60309 3P+G 9Hr IP44 Input, (24) c13 208VAC 3 Phase Delta (24) c13 60A
STV-4103D/NH &
SEV-4103D/NH

** Custom ** Switched CDU with PIPS, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plug, 32 inch Cord, Top Power Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers 208VAC 3 Phase Delta (24) c13 60A
STV-4103T &
SEV-4103T
Switched CDU with PIPS, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 60A, Unterminated / Blunt Cut, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers 208V (24) c13 60A
STV-4103V Switched 3 Phase PDU 208VAC CS8365 Input, (24) c13 208VAC (24) c13 50A
STV-4302 High Density 48 outlet Switched CDU with PIPS power monitoring 208 or 240 (3 Phase) (48) IEC 60320/C13 20A or 30A
CW-24VDE313A1
Switched CDU, 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 3 x LED Amp Meters, 3-phase Delta, 30A w/ NEMA L15-30P Cord Set, 10ft (3m), Bottom Cord Entry, 2 x Temp/Humid Capable, w/ Retractable Fuses
CW-24VY-L30M/Z2
Switched CDU Master unit, 24 x Switched IEC C13 Outlets, 1 x NEMA 5-20R utility outlet, 3-Phase Wye 30A, 3 x LED Meter, 15Ft NEMA L21-30P cordset, (2) Temperature/Humidity Sensor Capable, w/ fuse extractors
CW-24VYM313A1
Switched CDU, 0U, 18 x IEC C13 & 6 x IEC C19, 1 x NEMA 5-20R Utility Outlets, 3 x LED Amp Meters, 3-phase Wye, 30A w/ NEMA L21-30P Connector, 10ft (3m) Cord Set, Bottom Entry, (2)Temperature/Humidity Sensor Capable, w/ retractable Fuses
CW-48VD1411 Switched CDU, 0U, 48 x IEC C13 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 60A, Unterminated 10 ft (3 m)Cord, Bottom/Front Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, 20A Breaker Branch Circuit Protection
CX-24V2G311A1 Switched CDU (Expansion Unit), 0U, 18 x IEC C13 Outlets and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 30A input w/ L6-20P connector and cord, Bottom/Front Cord Entry, 3m (10') Cord, Retractable Fuses
CX-24VDE313A1 Switched CDU (Expansion Unit), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 3 x LED Amp Meters, 3-phase Delta, 30A w/NEMA L15-30P Cord Set, 10ft (3m), Bottom Cord Entry, w/ Retractable Fuses
CX-24VY-L30M/Z2 Switched CDU (Expansion Unit), 0U, 24 x IEC C13 Outlets, 1 x NEMA 5-20R utility outlet, 3-Phase Wye 30A, 3 x LED amp meters, 15ft NEMA L21-30P cordset w/ fuse extractors (NA)
CX-24VYM313A1 Switched CDU (Expansion Unit), 0U, 18 x IEC C13 & 6 x IEC C19, 1 x NEMA 5-20R Utility Outlets, 3 x LED Am


*PIPS - (Per Input Power Sensing) Active Power, Apparent Power, Energy k-Wh, Power Capacity, Reactance, and Power Capacity Used using the network interface. See the aggregate current draw, in Amps, locally using the onboard LED.



Features for the Switch PDU Series:


Easily replace fuses on your power monitoring PDU

Branch Circuit Protection

The Server Technology Sentry CDU Family meets the UL 60950-1 requirement for branch circuit protection.

Power monitoring PDUs have digital true RMS LED displays

Input Current Monitoring

Exclusive Digital True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital display on the switch PDU enclosure reports the aggregate current draw of the branch circuit.

Attach environmental sensors to your power monitoring PDU

Temperature and Humidity

The switch PDU supports two external 10ft (3m) probes. Each of these probes measures both Temperature and humidity. Receive SNMP-based alerts or email notifications from your switch PDU when conditions exceed defined thresholds.

Pops Pips

PIPS - Per Input Power Sensing

Accurately measures active power, apparent power, energy k-wh, power capacity, reactance, and power capacity used using the network interface. See the aggregate current draw, in Amps, locally using the onboard LED.
 

Add a redundant PDU

Connect an Expansion Cabinet power distribution unit to any switch PDU* to control two power input circuits and manage outlets (individual or groups) under 1 IP address.

* With the exception of CW-2H IPM-2

 

Remote Power Control

Individual or group outlet remote power control to cycle power and remotely reboot any selected servers or other network devices. Use TCP/IP (HTTP, HTTPS, SSH, Telnet, SNMP) or RS-232 to communicate with each switch PDU and rectify locked-up network devices. Assign outlets to a group for control of dual-power supply servers and other gear with a single command. Create an unlimited number of groups with any combination of outlets associated to each group. Reduce Mean Time to Repair (MTTR) a failing server by controlling individual power outlet receptacles on the switch PDU to reboot any selected device.

 

SNMP Management & Event Notification

Server Technology switch PDU products support SNMP. This allows network management systems to use SNMP requests to retrieve information from the unit and control power for the individual outlets. The switch PDU includes SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension is also supported to provide network access power control. SNMP traps can be generated for various events.

 

Secure Access - SSH or SSL Protection

SSH is a Unix-based command interface and protocol for securely getting access to a network access device. The switch PDU supports SSHv2. SSL is a commonly-used protocol for managing the security of a message transmission on the internet. The switch PDU supports SSLv3/TLSv1.

 

LDAP/LDAPS

The switch PDU supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enables authentication with LDAP servers. Administrators can pre-define and configure a set of necessary LDAP groups, and access rights for each group.

 

RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, console port access switch, or terminal server.





Call Us: 1-978-452-2299
First Name:
Last Name:
Company:
Address:
Mail Stop:
City:
State (if in US):
Province/Region (if outside US):
Country:
ZIP (Postal) Code:
E-mail:
Telephone:
Fax:
Questions/Comments:
Verification: Please type:
Please have a Bomara Associates representative contact me


View Full Site View Mobile Optimized