RS-232 Data Broadcast Units

DataReach Model DBU-41A
Applications:
· Electronic "Y" cable
· Send data to multiple printers
· Broadcast to remote display monitors
· Send redundant data to backup equipment
Features:
· 4 and 8 port models
· Code transparent
· Loopback Feature
· Plug and play configuration
The WTI data broadcast units are ideal for sending copies of data to
remote display monitors, video terminals or multiple printers. The units
can also be used to send duplicate data for fail-safe backup or redundant
storage purposes. Data sent to the DBU's master port is filtered, the
signals are boosted, and the data is sent out all 4 or 8 terminal ports.
The DBU output ports simulates standard modem interface (DCE) and is compatible
with standard RS-232 terminal data cable. The DBU master port simulates
a standard terminal interface (DTE).
The loopback feature can be used to perform a data transmission test.
When the loopback feature is enabled, data that is sent from the master
terminal to the DBU will be echoed back to the master port. The "Looped
Back" data can then be compared with the data that was originally
transmitted. The Loopback feature can be enabled or disabled by simple
DIP switch settings.
General Specifications:
Model DBU-41A: Master Port: DB-25 female (DTE)
· Output Ports: 4 DB-25 female (DCE)
· Signals Passed: TXD, RXD, DCD, DTR, CTS
· Power: 115/230 VAC 10 Watts
· Size: 3"H x 10.5"W x 6.5"D
Model DBU-81 Master Port: DB-25 female (DTE)
· Output Ports: 8 DB-9 female (DCE)
· Signals Passed TXD, RXD, DCD , DTR, CTS
· Power 115/230 VAC 5 Watts
· Size 1.75"H x 19"W x 6.5"D (one rack unit)
|