| Interface
Descriptions: |
| Network Interface: |
10/100Base-T,
RJ45, Multi-session SSH and/or Telnet (16) |
| RS-232
Interface: |
|
| Connectors: |
16
DB-9M connectors (DTE Pin-Out) |
| Coding: |
7/8
Bits, Even / Odd / No Parity, 1, 2 Stop Bits. |
| Flow
Control: |
XON/XOFF,
RTS/CTS, Both, None. |
| Data
Rate: |
300
bps to 115,200 bps. |
| Operation: |
| Password: |
16
Characters per Port - Case Sensitive. |
| Break: |
Send
Break or Inhibit Break. |
| Memory: |
Stores
parameters and captured data. 32K per port. |
| Timeout: |
"No
Activity" disconnects port/modem session: None, 1, 5, 15, 30 Seconds,
1, 5, 15, 30, 90 Minutes. |
| Port
Name: |
16
Characters per Port. |
| Site
ID: |
32
Characters. |
| Status
LEDs: |
Power
ON, Ready, Data Activity (16.) |
| Power: |
| AC Model: |
IEC-320
Inlet, 110 - 230 VAC, 50/60 Hz, 5 Watts, Auto Sensing Power Supply. |
| Physical
/ Environmental: |
| Size: |
| Height: |
1.75" (4.4 cm) or One (1) Rack-U |
| Depth: |
6.50" (16.5 cm) |
| Width: |
19.00" (48.3 cm)
19" (48.3 cm) Rack Mounts Included. |
|
| Weight: |
6.0
Lbs. (2.7 Kg) Shipping Weight |
Operating
Temperature: |
41°F
to 122°F (0°C to 50°C) |
Storage
Temperature: |
-4°F
to 128°F (-20°C to 70°C) |
| Humidity |
10
to 90% RH |