| Click on Model for picture! |
|
Model |
U91-1.0K |
|
|
|
|
|
|
Capacity
(kVA/kW) |
1kVA/1kW |
1.5kVA/1.5kW |
3kVA/3kW |
4kVA/4kW |
5kVA/5kW |
8kVA/8kW |
|
Dimensions (H x W x D) (inches) |
(3U) 5 x 17.75 x 24 |
29
x 10.5 x 25.75 |
32
x 13 x 33 |
|
Dimensions (mm) |
127 x 444 x 609 |
737
x 267 x 654 |
813
x 330 x 838 |
|
Weight
(lb) |
80 |
84 |
280 |
280 |
295 |
490 |
|
Weight
(kg) |
37 |
38 |
127 |
127 |
134 |
222 |
|
Input
Connection |
5-20P Hospital Grade |
|
Hardwired
input |
|
Output
Connection |
(3) 5-15R Hospital Grade |
|
|
Typical
Runtime in minutes (full "100%" load) |
8 |
5 |
13 |
9 |
6.5 |
11 |
|
(80%
load) |
12 |
6.5 |
18 |
12 |
9 |
14 |
|
(half
load) |
22 |
12 |
35 |
24 |
18 |
25 |
|
AC
Input Voltage Range |
147-264
(for nominal 200/208/220/230/240V output) |
|
Input
Nominal Current at Full Load
|
100-120V – 14-12A Max. |
100-120V – 19-16A Max. |
200V–17A |
200V–22A |
200V–28A |
200V–45A |
|
208V–17A |
208V–22A |
208V–27A |
208V–43A |
|
220V–16A |
220V–20A |
220V–25A |
220V–41A |
|
230V–15A |
230V–20A |
230V–24A |
230V–39A |
|
240V–14A |
240V–19A |
240V–23A |
240V–38A |
|
Operating
Frequency
|
50Hz
or 60Hz nominal |
|
On
line: output frequency tracks input within adjustable limits
(±3Hz
default) |
|
On
inverter: ±0.15Hz |
|
Nominal
Output |
100/110/115/120 nominal output
voltage |
100/110/115/120/200/208/220/230/240
nominal output voltage |
|
Output
Voltage Regulation |
±5%
of nominal output voltage |
|
Output
Voltage Waveform |
Sinewave,
computer-grade power with 5% THD at rated kW load |
|
Overload
Capacity |
200% Surge
|
200%
surge for a minimum of 2.5 seconds / 110% surge for a minimum
of 10 minutes |
|
Transfer
Time |
0
mS |
|
Lightning,
Surge, and Noise Protection
|
200
Joule surge suppression rating. 0.7% Let-Through-Voltage (LTV).
Tested to ANSI/IEEE. |
|
C62.41
Categories A3 and B3 tests. Common Mode – up to 50dB. Normal Mode
– up to 90dB. |
|
Separately
derived power source per NEC Article 250-5d. |
|
Efficiency
(on line) |
95% |
95% |
95% |
96% |
96% |
96% |
|
Recharge
Time (to 85% charge) |
2-3 hours |
3-4
hours |
|
Safety
Certification |
UL
2601-1 / UL 60601-1, UL 1778, cUL |
|
EMC
Compliance |
FCC-B, CISPR 11 |
FCC-A, Vfg 243/1991,
Vfg 46/1992, CISPR 22 |
|
Testing
Standards |
EN 60601-1-2, EN 55011, EN 61000-3-2, EN 61000-3-3, C62.45 (1972), EN 61000-4-2, EN 61000-4-3, EN 6100-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 |
ANSI/IEEE C62.45 (1987); IEC 801-2, 801-3, 801-4, 801-5 |
|
Communication
|
RS-232 port (DE9) featuring full-duplex serial communication, alarm contacts, inverter contacts, and remote shutdown |
|
|
|
|
Operating
Temperature |
0
degrees to +40 degrees C |
|
Storage
Temperature |
-20
degrees to +60 degrees C (-20 degrees to +40 degrees C if battery
is not removed) |
|
Relative
Humidity |
0
to 95% without condensation |
|
Audible
Noise at 1 meter |
Less than 40dBA |
|
Heat
(on line) (BTU/hr) |
270 |
539 |
569 |
711 |
1138 |
|
Heat (on line) (kW/hr) |
0.08 |
0.158 |
0.167 |
0.208 |
0.333 |
|
Altitude |
Maximum
ambient operating temperature drops by 1 degree C per 305 meters
(1000 feet) above sea level, maximum elevation being 3050 meters
(10,000 feet). |