Accratech »
PowerRx
PoweRx
UPS Models
Superior power integrity
and management for medical and laboratory applications. Efficient,
reliable and cost-effective UPS uses high-speed microprocessor and
line-interactive technology.
NOTE: Medical Grade Models are listed
to UL2601-1, cUL22.2 No. 2601-1, or IEC60601.1
|
|
Models |
U93-350 |
U93-500 |
U93-800 |
U93-1100 |
U93-1440 |
| Capacity (VA/W) |
350VA/280W |
500VA/325W |
800VA/520W |
1100VA/715W |
1440VA/936W |
| Dimensions: H x W
x D (inches) |
6.6 x 5.5 x 17.5 |
8.0 x 5.8 x 17.5 |
8.0 x 5.8 x 17.5 |
9.0 x 8.3 x 19.5 |
9.0 x 8.3 x 19.5 |
| (mm) |
168 x 140 x 445 |
203 x 147 x 445 |
203 x 147 x 445 |
229 x 211 x 495 |
229 x 211 x 495 |
| Weight: (lb) |
28 |
35 |
41 |
61 |
62 |
| (kg) |
13 |
16 |
19 |
28 |
28 |
| Input Connection |
5-15P Hospital Grade |
| Output Connection |
(4)
5-15R Hospital Grade |
(6) 5-15R
Hospital Grade |
| Typical Runtime: (80%
Load) |
6 |
| (minutes) (Half
Load) |
20 |
| AC Input Voltage Range |
96 - 151 VAC |
| Input Nominal Current at
Full Load |
100V=4.07A |
100V=5.50A |
100V=8.39A |
100V=11.23A |
100V=13.67A |
110V=3.55A |
110V=4.92A |
110V=7.58A |
110V=10.15A |
110V=12.78A |
120V=3.2A |
120V=4.5A |
120V=7.0A |
120V=9.5A |
120V=12.0A |
| Operating Frequency |
60 Hz |
Ouput frequency, AC Mode: 60 Hz+/- 3Hz,
Inverter Mode:60 Hz +/- 0.1 Hz |
| Nominal Output |
120 Norminal Output Voltage |
| Output Voltage Regulation |
AC Mode: Output Voltage Regulation : +/-
3%, Output Regulation(
On Inverter): +/- 5% |
| Output Voltage Waveform |
Sinewave |
| Overload Capacity |
AC Mode: 110 % |
| Transfer Time |
4 mS typical |
| Lightning, Surge and Noise
Protection |
Tested to ANSI/IEEEC62.41
Catergory A&B(formerly
IEEE587-1980) -Category A 6000V/200A, 0.5 Micro seconds Risetime, |
100kHz decay, Category B 6000V/500A, 0.5
Micro seconds risetime 100 kHz decay. |
Normal Mode: -60dB, Common Mode: -80 dB;
Surge Energy 440 Joules |
| Efficiency (on line) |
92% |
93% |
94% |
| Recharge Time (to 85% charge) |
4 hours |
| Safety Certification |
UL 2601, UL 1778, cUL22.2 No. 601.1 |
| EMC Compliance |
FCC Part 15 |
| Testing Standards |
ANSI/IEEE C62.41 Category
A & B (Formerly
IEEE587-1980) |
| Communication |
N/A |
|
Operation |
|
| Operating Temperature |
0 degrees to +40 degrees C. |
| Storage Temperature |
-20
degrees to +60 degrees C (-20 degrees to +40 degrees C if battery
is not removed) |
| Relative Humidity |
5 to 90% without condensation |
| Audible Noise at
lm |
<45dB |
<45dB |
<45dB |
<45dB |
<45dB |
| Heat (on
line): (BTU/hr.) |
100 |
125 |
200 |
225 |
250 |
| (kW/hr.) |
0.029 |
0.036 |
0.058 |
0.065 |
0.0725 |
| Altitude |
Maximum
ambient operating temperature drops by 1 degree C per 305 meters
(1000 feet) above sea level, the maximum elevation being 3000 meters
(10,000 feet). |
| NOTE:
Medical Grade Models are listed to UL2601-1, cUL22.2 No. 2601-1,
or IEC60601.1 |
International
Models |
U93-350I |
U93-500I |
U93-800I |
U93-1100I |
U93-1440I |
| Capacity (VA/W) |
350VA/280W |
500VA/325W |
800VA/520W |
1100VA/715W |
1440VA/936W |
| Dimensions: H x W
x D (inches) |
6.6 x 5.5 x 17.5 |
8.0 x 5.8 x 17.5 |
8.0 x 5.8 x 17.5 |
9.0 x 8.3 x 19.5 |
9.0 x 8.3 x 19.5 |
| (mm) |
168 x 140 x 445 |
203 x 147 x 445 |
203 x 147 x 445 |
229 x 211 x 495 |
229 x 211 x 495 |
| Weight: (lb) |
28 |
35 |
41 |
61 |
62 |
| (kg) |
13 |
16 |
19 |
28 |
28 |
| Input Connection |
IEC
Inlet |
| Output
Connection |
4
- IEC |
6
- IEC |
| Typical Runtime: (80%
Load) |
6 |
| (minutes) (Half
Load) |
20 |
| AC
Input Voltage Range |
192
- 302 VAC |
| Input
Nominal Current at Full Load |
230V=1.5A |
230V=2.2A |
230V=3.5A |
230V=4.8A |
230V=6.3A |
| Operating
Frequency |
50/60
Hz Auto-sense |
Ouput
frequency, AC Mode: 50/60 Hz+/- 3Hz, Inverter Mode: 50/60 Hz
+/- 0.1 Hz |
| Nominal Output |
230
Norminal Output Voltage |
| Output
Voltage Regulation |
AC
Mode: Output Voltage Regulation : +/- 3%, Output Regulation( On Inverter): +/-
5% |
| Output Voltage Waveform |
Sinewave |
| Overload
Capacity |
AC
Mode: 110 % |
| Transfer Time |
4 mS typical |
| Lightning,
Surge and Noise Protection |
Tested
to ANSI/IEEEC62.41 Catergory A&B(formerly IEEE587-1980) -Category
A 6000V/200A, 0.5 Micro seconds Risetime, |
100kHz
decay, Category B 6000V/500A, 0.5 Micro seconds risetime 100 kHz
decay. |
Normal
Mode: -60dB, Common Mode: -80 dB; Surge Energy 440 Joules |
| Efficiency (on line) |
92% |
93% |
94% |
| Recharge
Time (to 85% charge) |
4
hours |
| Safety Certification |
UL
2601-1, UL 1778, cUL C22.2 No. 601.1, VDE Listed to IEC60601-1
and EN 60601 |
| EMC
Compliance |
FCC
Part 15 |
| Testing Standards |
ANSI/IEEE C62.41 Category
A & B (Formerly IEEE587-1980) |
| Communication |
N/A |
Operation |
|
| Operating
Temperature |
0 degrees to +40 degrees
C. |
| Storage
Temperature |
-20
degrees to +60 degrees C (-20 degrees to +40 degrees C if battery
is not removed) |
| Relative
Humidity |
5 to 90% without condensation |
| Audible
Noise at lm |
<45dB |
<45dB |
<45dB |
<45dB |
<45dB |
| Heat (on
line): (BTU/hr.) |
100 |
125 |
200 |
225 |
250 |
| (kW/hr.) |
0.029 |
0.036 |
0.058 |
0.065 |
0.0725 |
| Altitude |
Maximum
ambient operating temperature drops by 1 degree C per 305 meters
(1000 feet) above sea level, the maximum elevation being 3000 meters
(10,000 feet). |
|