Accratech Medical and Laboratory Grade UPS
Accratech Medical and Laboratory Grade Uninterruptible Power Supplies (UPS) - by Bomara
Loading
Bomara Associates Homepage

Accratech » PowerRx

PoweRx UPS Models

Superior power integrity and management for medical and laboratory applications. Efficient, reliable and cost-effective UPS uses high-speed microprocessor and line-interactive technology.

NOTE: Medical Grade Models are listed to UL2601-1, cUL22.2 No. 2601-1, or IEC60601.1
Models
U93-350
U93-500
U93-800
U93-1100
U93-1440
Capacity (VA/W)
350VA/280W
500VA/325W
800VA/520W
1100VA/715W
1440VA/936W
Dimensions: H x W x D (inches)
6.6 x 5.5 x 17.5
8.0 x 5.8 x 17.5
8.0 x 5.8 x 17.5
9.0 x 8.3 x 19.5
9.0 x 8.3 x 19.5
                                     (mm)
168 x 140 x 445
203 x 147 x 445
203 x 147 x 445
229 x 211 x 495
229 x 211 x 495
Weight:                         (lb)
28
35
41
61
62
                                     (kg)
13
16
19
28
28
Input Connection
5-15P Hospital Grade
Output Connection
(4) 5-15R Hospital Grade
(6) 5-15R Hospital Grade
Typical Runtime:          (80% Load)
6
(minutes)                      (Half Load)        
20
AC Input Voltage Range
96 - 151 VAC
Input Nominal Current at Full Load
100V=4.07A
100V=5.50A
100V=8.39A
100V=11.23A
100V=13.67A
110V=3.55A
110V=4.92A
110V=7.58A
110V=10.15A
110V=12.78A
120V=3.2A
120V=4.5A
120V=7.0A
120V=9.5A
120V=12.0A
Operating Frequency
60 Hz
Ouput frequency, AC Mode: 60 Hz+/- 3Hz, Inverter Mode:60 Hz +/- 0.1 Hz
Nominal Output
120 Norminal Output Voltage
Output Voltage Regulation
AC Mode: Output Voltage Regulation : +/- 3%,  Output Regulation( On Inverter): +/- 5%
Output Voltage Waveform
Sinewave
Overload Capacity
AC Mode: 110 %
Transfer Time
4 mS typical
Lightning, Surge and Noise Protection
Tested to ANSI/IEEEC62.41 Catergory A&B(formerly IEEE587-1980) -Category A 6000V/200A, 0.5 Micro seconds Risetime,
100kHz decay, Category B 6000V/500A, 0.5 Micro seconds risetime 100 kHz decay.
Normal Mode: -60dB, Common Mode: -80 dB; Surge Energy 440 Joules
Efficiency (on line)
92%
93%
94%
Recharge Time (to 85% charge)
4 hours
Safety Certification
UL 2601, UL 1778, cUL22.2 No. 601.1
EMC Compliance
FCC Part 15
Testing Standards
ANSI/IEEE C62.41 Category A & B (Formerly IEEE587-1980)
Communication
N/A
Operation
 
Operating Temperature
0 degrees to +40 degrees C.
Storage Temperature
-20 degrees to +60 degrees C (-20 degrees to +40 degrees C if battery is not removed)
Relative Humidity
5 to 90% without condensation
Audible Noise at lm
<45dB
<45dB
<45dB
<45dB
<45dB
Heat (on line):            (BTU/hr.)
100
125
200
225
250
                                   (kW/hr.)
0.029
0.036
0.058
0.065
0.0725
Altitude
Maximum ambient operating temperature drops by 1 degree C per 305 meters (1000 feet) above sea level, the maximum elevation being 3000 meters (10,000 feet).
NOTE: Medical Grade Models are listed to UL2601-1, cUL22.2 No. 2601-1, or IEC60601.1

International Models
U93-350I
U93-500I
U93-800I
U93-1100I
U93-1440I
Capacity (VA/W)
350VA/280W
500VA/325W
800VA/520W
1100VA/715W
1440VA/936W
Dimensions: H x W x D (inches)
6.6 x 5.5 x 17.5
8.0 x 5.8 x 17.5
8.0 x 5.8 x 17.5
9.0 x 8.3 x 19.5
9.0 x 8.3 x 19.5
                                     (mm)
168 x 140 x 445
203 x 147 x 445
203 x 147 x 445
229 x 211 x 495
229 x 211 x 495
Weight:                         (lb)
28
35
41
61
62
                                     (kg)
13
16
19
28
28
Input Connection
IEC Inlet
Output Connection
4 - IEC
6 - IEC
Typical Runtime:          (80% Load)
6
(minutes)                      (Half Load)        
20
AC Input Voltage Range
192 - 302 VAC
Input Nominal Current at Full Load 230V=1.5A 230V=2.2A 230V=3.5A 230V=4.8A 230V=6.3A
Operating Frequency
50/60 Hz Auto-sense
Ouput frequency, AC Mode: 50/60 Hz+/- 3Hz, Inverter Mode: 50/60 Hz +/- 0.1 Hz
Nominal Output
230 Norminal Output Voltage
Output Voltage Regulation
AC Mode: Output Voltage Regulation : +/- 3%,  Output Regulation( On Inverter): +/- 5%
Output Voltage Waveform
Sinewave
Overload Capacity
AC Mode: 110 %
Transfer Time
4 mS typical
Lightning, Surge and Noise Protection
Tested to ANSI/IEEEC62.41 Catergory A&B(formerly IEEE587-1980) -Category A 6000V/200A, 0.5 Micro seconds Risetime,
100kHz decay, Category B 6000V/500A, 0.5 Micro seconds risetime 100 kHz decay.
Normal Mode: -60dB, Common Mode: -80 dB; Surge Energy 440 Joules
Efficiency (on line)
92%
93%
94%
Recharge Time (to 85% charge)
4 hours
Safety Certification
UL 2601-1, UL 1778, cUL C22.2 No. 601.1, VDE Listed to IEC60601-1 and EN 60601
EMC Compliance
FCC Part 15
Testing Standards
ANSI/IEEE C62.41 Category A & B (Formerly IEEE587-1980)
Communication
N/A
Operation
 
Operating Temperature
0 degrees to +40 degrees C.
Storage Temperature
-20 degrees to +60 degrees C (-20 degrees to +40 degrees C if battery is not removed)
Relative Humidity
5 to 90% without condensation
Audible Noise at lm
<45dB
<45dB
<45dB
<45dB
<45dB
Heat (on line):            (BTU/hr.)
100
125
200
225
250
                                   (kW/hr.)
0.029
0.036
0.058
0.065
0.0725
Altitude
Maximum ambient operating temperature drops by 1 degree C per 305 meters (1000 feet) above sea level, the maximum elevation being 3000 meters (10,000 feet).

 



Accratech Home
Bomara Homepage
Request Information

Bomara Associates Phone: 800.5BOMARA (800.526.6272) Phone: 978.452.2299 Fax: 978.452.1169 3 Courthouse Lane, Chelmsford, MA 01824 USA
email: bobr@bomara.com     web: www.bomara.com
Serving the marketplace for over 35 years