SPECIFICATIONS - PRICE
Operating temperatures 0 to 70C.
Mechanical Relay duty cycle 20 million operations at 18,000 operations per hour.
Electrical is 300,000.
Relay operating temperature is (-25 to 70 C).
RoHS compliant

Universal AC Power Switch (U-X3)
Item No SWTUX3-CP

Universal AC Power Switch (U-X3 with North American NEMA-15 connectors)
Item No SWTUX3-NA

Physical 6.25" W x 4.25" D x 2.25" H, 1 lbs.
Connectors
(2) RJ-11 TelCo/Control,
(1) USB,
(4) AC Receptacles (IN/OUT)
LEDs (5) Port, Power, TX/RX
Switches (1) On/Off 15 Amp breaker
Bell (1) Audible Response
Cable (1) 7' RJ-11 Phone Cable
Adaptor None
AC Power
115V/50-60Hz, 15 Amps to
220V/50Hz, 10 Amps

---------- OPTIONAL ADAPTERS ------------

RJ FILTERED ADAPTER (9 PIN to RJ-11)
Item No
CA9R11-IPN-F Price Contact Bomara
(Required for Serial Port Connection)

------------ POWER CORDS ----------------

OPTIONAL AC POWER CORDS and ADAPTERS
Since it is not possible to stock all possible power cords and adapters, the customer can acquire them locally. However, CPS does stock a limited number of cords and adapters that will cover about 90% of all applications. Select those that may apply to your application from the list below. Also see the diagram above.

 

IPC AC Power Side Options

IN AC Adapter Cords - FROM POWER MAIN TO THE IPC
(Country Connector to IEC 320-14)

A - North American 110-115V 6 foot
(NEMA 5-15 Receptacle to IEC C13)
Item No
NA-IPC

A - European 6 feet two prong

Item No E2-IPC
OUT AC Adapter Cords - FROM IPC to the EQUIPMENT
B - PC Extension 6 foot (IEC 320-C13 to IEC 320-C14)
Item No IPC-PCX
C - North American 1 foot
(IEC 320-C13 to Equipment, PC, Power Strip, etc.)
Item No IPC-NA
D - Universal Adapter
(Connects to the IPC OUT and accepts any country AC connector)
Item No IPC-UV

---------- REMOTE CONTROLLERS -----------

Optional Internal Touch Tone Controller (ITTO)
Item No ITTOARRC

Optional External Controllers
External TELEPHONE LINE Controllers
SP-RRC One Telco Line and One Control Port (to U-X3)
Item No SWTSPRRC
3P-RRC
One Telco Line and Three Control Ports (to U-X3)

Item No
SWT3PRRC
FTS
One Telco Line and Three Control Ports (to U-X3)

Item No SWTFTS
FTS-8
One Telco Line and Eight Control Ports (to U-X3)

Item No
SWTFTS8
NETWORK Controller
N-RRC One RJ-45 TCP/IP Network Connection and One Control Port (to U-X3)
Item No SWTRRC-N
Cell Controller
C-RC One RS-232 port and one Control Port (to U-X3)
Item No SWTCRC

See the specific Controller for additional specifications

WHAT IS IT?
The U-X3 is an economical, but extremely flexible AC power control device that can be used to control the AC power to three different devices. Up to ten U-X3s can also be daisy chained together to control up to thirty devices. They can be located up 2000' apart, cumulative.

The U-X3 supports input AC voltages from 110V to 250V and has a 15 Amp circuit breaker. It uses internationally standard IEC320 AC connectors. This combination allows it to be used anywhere in the world with locally available power cords. Various AC power cords as well as a Universal Adapter that provides connections for any type of AC Plug in the world are also optionally available.

The U-X3 provides a number of methods to control it, allowing it to be used locally or remotely for a number of different applications; from simply resetting DSL modem/routers to automatically resetting kiosks or other equipment that may hang from time to time. Or even to turn the power ON or OFF on certain equipment for protection, security or simply to add a little green to the environment.

THE HARDWARE
The back panel has one Input IEC320-C13 AC Jack and three Controlled IEC320-C14 Output AC jacks.

The front panel supports three multi-function connectors. A USB connector and two RJ-11 connectors, any of which can be used to configure the unit or to send the ON/OFF/RESET power control commands, depending on the application. The RJ-11s provide the connection for a standard telephone line for remote control. They are also used for the RS-232 and Upstream Downstream connections as well as to connect other external CPS controllers or Base Units.

SETUP PREFERENCES
The operating parameters can also be changed to meet various requirements. The port delay times, reset delay time, power ON delay, power up state, ring count etc... These preferences are normally entered through the USB or serial ports with simple ASCII commands from a PC.

Example:

*0S1 would change the AC outlet separation ON time delay to 1 min.
*PR2 would change the OFF time for a RESET to 20 seconds.

See instructions for a complete list. Once the setup preferences are defined, any ON/OFF/RESET command or manual power ON/OFF will be executed accordingly. You can also make inquires as to the setup preferences. They are confirmed by local on screen replies or audible "beeps" over the phone line.

HOW IT CAN BE CONTROLLED?
Local Control is provided through a USB port or the Serial/TelCo port (adapter required). The local PC can send simple ON/OFF/RESET Commands to the desired AC Jacks on a single unit or all of the units in a daisy chain. See Command Examples below.

Remote Control over a standard telephone line is provided through the Ring Count RESET feature (standard). This feature simply counts the rings and RESETS once the ring threshold is reached.

Our new (optional) Internal Touch Tone Option (ITTO) is also available. It provides a multi-level password and allows the ON/OFF/RESET commands as well as inquires to be sent using a touch tone key pad. It can also share the line with other devices (phone, fax, TAD, but no inbound modem) and allows some of the set up preferences to be changed remotely as zwell. The commands may also be appended to a modem's AT dial string for more automated entry, even though there is no modem at the U-X3 end. Multiple ITTOs/U-X3s with different passwords may also be connected to the same phone line.

External Remote Controllers are also available to provide additional methods of remote access.
Touch-Tone Controller (SP-RRC), is used when sharing the TelCo line with a modem or to control an entire daisy chain of U-X3s without the ITTO option.
Multi-Port Controller (MP-RRC), is use to connect several UX-3s in multiple daisy chains (3 or 8 port models), and control them with Touch-tones.
IP Controller (N-RRC), use for remote control over the Internet or any TCP/IP network.
Cell Controller (C-RC) is used where no phone line or network access is available. Text or e-mail the AC Power Commands to the U-X3s.
Other controllers are also available, but these are the more popular.

FLEXIBILITY Wow!
You can use any of these methods as your primary method of control and one or more of the others as backup. As an example, use the Heartbeat software to automatically reset the server and the telephone line touch tone or Ring Reboot feature to turn the server ON or OFF or force a RESET from a remote location.

Or use the External IP Controller (N-RRC) as your primary method of AC power control, but when the network equipment is down, you can rely on the Auto Ping to automatically reset it or use any of the "out of band" touch-tone option or Ring count RESET feature to reset the Router modem etc.

Of course all of this can be changed along with a number of other operating parameters through the USB port on the U-X3. It is truly a remarkable device. Its flexibility allows it to be used for a variety of power control requirements. It will keep your blood pressure in check and miles off of you car.

AC Power Command Examples
These examples are presented to provide a feel as to what is required to send an AC Power Command via: a Serial (RS-232/USB) Port, External Controller, Modem or the Internal Touch Tone Controller (ITTO).

A typical serial port command to RESET POWER on Box #2, Port #1 is     *213
Where "*" is the attention code, "2" is the box address, "1" is the address for the AC Outlet and "3" is the "Action Command",("1" = ON and "2" = OFF)

If this were sent as a touch-tone command through an External Telephone Line Controller, it would be preceded with the controller #, Password (up to six numbers), and the Port number of the Controller (multi-port units) that the Power Strip is attached to:

# 8 Password Port 213#

This could also be sent from a modem by appending it to the AT dial string. Even though there may not be a modem at the Power Strip end.

ATDT 7709450643@ # 8 Password Port 213#

Wild card and Global Commands are also available.

*PON This "global Command" will turn ON all of the ports on all of the boxes according to the delays applied in the setup
*POF will turn them all OFF
*#31 This "wild card Command" (#) will Turn ON the power on port 3 of all of the boxes in a daisy chain. The wild card can be used in any or all positions.

To send this command via Touch-Tones to the Internal Controller (ITTO) enter

# Password # "bb" #013.

The manual ON/OFF switch can also be used to power the CPS ON or OFF. It will power ON according to the preferences that you selected.

Features

Application Diagram

  • In-band or out-of-band remote reboot switch
  • Local Serial Port Control (USB or RS-232)
  • Ring Count RESET Trigger
  • Internal Touch-Tone Control Option
  • Remote Access Controllers (TCP/IP, Cellphone)
  • Change Configuration Preferences
  • Daisy Chain up to 10 Units (150 amps)
  • Select AC Outlets Individually
  • Compatible with CPS Auto Reboot software
  • Standard IEC320 AC connectors
  • 15 Amp breaker
U-X3 Application Diagram




Call Us: 1-978-452-2299
First Name:
Last Name:
Company:
Address:
Mail Stop:
City:
State (if in US):
Province/Region (if outside US):
Country:
ZIP (Postal) Code:
E-mail:
Telephone:
Fax:
Questions/Comments:
Verification: Please type:
Please have a Bomara Associates representative contact me


View Full Site View Mobile Optimized