Bomara Associates Logo
Bomara Associates Homepage

North American Rackmount Power Conditioner
ABCE600-11IECR
PN # 56060-23GR

 

 
ABCE600-11IECR
PN # 56060-23GR
Type
Medical Grade - Listed to UL60601
VA Ratings
600
Watt Rating
420
Inverter Waveform
Low distortion sine wave
Transfer Time
4 ms. typical
Frequency
60 Hz.
BTU/Hr. Output
125
T.H.D. Max. %
<3% on battery
On Line Efficiency
93%
Input Voltage
120
Input Current
6.0 amps
Output Voltage
120
Output Current
5.0 amps
Input Voltage Range Without Using Battery
96-151 volts
Output Regulation (on line)
±10%
Output Regulation (on battery)
±5%
Backup time (full/half load)
6/20 minutes
Communications Interface
DB9, USB
Compliance
UL60601-1 and cUL C22.2 No. 60601-1, RoHS
Shipping Weight (lbs.)
56
.

Front Panel Controls
• Power On/Off
• Test
• Load Level LED Gauge
• Battery Charge LED Gauge
• Output receptacle status
• Voltage Manager Boost LED
• Voltage Manager Nominal LED
• Voltage Manager Buck LED
• On Battery LED
• Replace Battery LED
• Overload LED

Rear Panel Information and Controls
• IEC320 Inlet Module
• Ten (10) NEMA 5-15R receptacles controllable via Communications Manager - spaced for DC power supplies
• Communications Manager DB9 port, USB port
• Circuit Breakers
• Battery enable plugs (also enables cold start on battery)

Internal Batteries
• User hot-swappable (see instruction manual)
• Type - varies by model. See below.

DC Buss Volts: 24
Batteries: 12V, 7AH x 2

• Recharge time - 4 hours to 80% capacity

Environmental
Temperature:
0 - +40° C (32 - 104°F) Operating
-20 - +60° C (-40 - +140° F) Shipment, Storage
Humidity: 5 - 90% non-condensing (Operating, Shipment, Storage)
Altitude: 3,000m (10,000 ft.) max. (Operating, Shipment, Storage)

Safety Agency Information
North American Standard models are UL and cUL listed to UL1778. International Standard models are UL listed. All models for international use carry the CE mark.

North American medical versions of this uninterruptible power manager meet all requirements for UL60601-1 and cUL C22.2 No. 60601.1.

International medical versions of this uninterruptible power manager meet all requirements for IEC60601-1 and European derivatives EN60601.

EMC Conformance

Low/High Voltage Models: FCC Part 15 J Class A (Class B optional)
International Voltage Models: FCC Part 15 J Class A (Class B optional) EN 55022 Class B/CISPR 22, EN 50091-2, IEC 61000-3-2

NOISE REJECTION-ISOLATION: With unit under power and an ANSI/IEEE C62.41Cat. A pulse applied either normal or common mode at the input, the noise output voltage will be less than 10V normal mode and less than 0.5V common mode in all four quadrants (CM-NM, NM-NM, CM-CM, NM-CM).
SURGE VOLTAGE WITHSTAND CAPABILITY: Tested under power to ANSI/IEEE C62.41 Cat. A & B (formerly IEEE587-1980). Cat. A - 6000V @ 200 amps, 0.5 µsec risetime, 100 kHZ decay, Cat. B - 6000V @ 500 amps, 0.5 µsec risetime, 100 kHZ decay.

NEMA 5-20P plug. Rear panel has 14 NEMA 5-20R receptacles. Front panel has 2 NEMA 5-20R receptacles.



Powervar Home Bomara Homepage Request Information

Bomara Associates Phone: 800.5BOMARA (800.526.6272) Phone: 978.452.2299 Fax: 978.452.1169 3 Courthouse Lane, Chelmsford, MA 01824 USA
email: bobr@bomara.com      web: www.bomara.com
Serving the marketplace for over 35 years