North American Ground Guard Conditioners - “B” Case Enclosure

 

 
ABCG065-11
Part# 66008-XX
ABCG100-11
Part# 66012-XX
ABCG152-11
Part# 61025-XX
ABCG202-11
Part# 61026-XX
ABCG302-11
Part# 61036-XX
ABCG402-11
Part# 61048-XX
VA Ratings
78
120
180
240
360
480
Frequency
60 Hz.
60 Hz.
60 Hz.
60 Hz.
60 Hz.
60 Hz.
BTU/Hr. Output
41
41
62
82
123
115
T.H.D Max. %
<1%
<1%
<1%
<1%
<1%
<1%
Load Surge Current @
1/2 cycle
10 amps
15 amps
28 amps
38 amps
82 amps
125 amps
1 second
3.6 amps
5.2 amps
10 amps
14 amps
28 amps
60 amps
10 seconds
2.0 amps
3.0 amps
4.5 amps
6.0 amps
10 amps
17 amps
Input Voltage
120
120
120
120
120
120
Output Voltage
120
120
120
120
120
120
Output Current
.65 amps
1.0 amps
1.5 amps
2.0 amps
3.0 amps
4.0 amps
Efficiency
90%
90%
90%
90%
90%
93%
Voltage Drop No Load to Full Load
10%
10%
10%
9%
6%
7%
Wall mountable*

Yes

Yes
Yes
Yes
Yes
Yes
Safety Agency Listing
UL and cUL
UL and cUL
UL and cUL
UL and cUL
UL and cUL
UL and cUL
Shipping Weight (lbs.)
5
7
8
9
11
12
* When ordering by model number, add "W" to model number above for wall mount option.

POWERVAR Part #
ABCG065-11—66008-XX**
ABCG100-11 - 66012-XX **
ABCG152-11 - 66025-XX**
ABCG202-11 - 66026-XX**
ABCG302-11 - 66036-XX**
ABCG402-11 - 6^048-XX**


**When ordering, add two digit number from below in place of XX to specify receptacle option desired.

 

 

Option 1 - ABCG065-11 and ABCG100-11 Only
-01 - 5-15P plug and one 5-15R IG duplex receptacle
-21 - 5-15P plug and one 5-15R IG duplex with wallmount

 

 

 

Option 2 - All Other B Case Models
-01 - 5-15P plug and two 5-15R IG duplex receptacle
-22 - 5-15P plug and two 5-15R IG duplex receptacles


Noise Rejection-Isolation: With unit under power and an ANSI/IEEE C62.41Cat. A pulse applied either normal or common mode at the input, the noise output voltage will be less than 10V normal mode and less than 0.5V common mode in all four quadrants (CM-NM, NM-NM, CM-CM, NM-CM).
Surge Voltage Withstand Capability: Tested under power to ANSI/IEEE C62.41 Cat. A & B (formerly IEEE587-1980). Cat. A - 6000V @ 200 amps, 0.5 µsec risetime, 100 kHZ decay, Cat. B - 6000V @ 500 amps, 0.5 µsec risetime, 100 kHZ decay.
Ground Current Attenuation: Disturbance current coupling into ground conductors is limited to .1% (one tenth of one percent) of the amplitude of the source disturbance current.
Ground impedance Safety Characteristics: Under worst case capacitive or inductive load conditions, when presented with a worst case fault current of 50% above the branch circuit breaker rating, the control impedance must not exhibit a voltage drop across itself of more than 2.5 volts AC at 60 Hz.