North American Ground Guard Conditioners - “C” Case Enclosure

 

 
ABCG400-11
Part # 66051-XX
ABCG500-11
Part # 66060-XX
ABCG600-11
Part #66072-XX
ABCG700-11
Part # 66084-XX
VA Ratings
480
600
720
840
Frequency
60 Hz.
60 Hz.
60 Hz.
60 Hz.
BTU/Hr. Output
115
123
147
143
T.H.D Max. %
<1%
<1%
<1%
<1%
Load Surge Current @
1/2 cycle
125 amps
175 amps
215 amps
237 amps
1 second
60 amps
84 amps
102 amps
114 amps
10 seconds
17 amps
24 amps
30 amps
33 amps
Input Voltage
120
120
120
120
Output Voltage
120
120
120
120
Output Current
4.0 amps
5.0 amps
6.0 amps
7.0 amps
Efficiency
93%
94%
94%
95%
Voltage Drop No Load to Full Load
7%
6%
6%
5%
Wall mountable*

Yes

Yes
Yes
Yes
Safety Agency Listing
UL and cUL
UL and cUL
UL and cUL
UL and cUL
Shipping Weight (lbs.)
16
18
20
22
* When ordering by model number, add "W" to model number above for wall mount option.

POWERVAR Part #
ABCG400-11 - 66051-XX**
ABCG500-11 - 66060-XX**
ABCG600-11 - 66072-XX**
ABCG700-11 - 66084-XX**


**When ordering, add two digit number from below in place of XX to specify receptacle option desired.

 

Option 1 - Standard Plugs/Receptacles
-02 - 5-15P plug and two 5-15R IG duplex receptacles
-22 - 5-15P plug and two 5-15R IG duplex receptacles
with wallmount


Noise Rejection-Isolation: With unit under power and an ANSI/IEEE C62.41Cat. A pulse applied either normal or common mode at the input, the noise output voltage will be less than 10V normal mode and less than 0.5V common mode in all four quadrants (CM-NM, NM-NM, CM-CM, NM-CM).
Surge Voltage Withstand Capability: Tested under power to ANSI/IEEE C62.41 Cat. A & B (formerly IEEE587-1980). Cat. A - 6000V @ 200 amps, 0.5 µsec risetime, 100 kHZ decay, Cat. B - 6000V @ 500 amps, 0.5 µsec risetime, 100 kHZ decay.
Ground Current Attenuation: Disturbance current coupling into ground conductors is limited to .1% (one tenth of one percent) of the amplitude of the source disturbance current.
Ground impedance Safety Characteristics: Under worst case capacitive or inductive load conditions, when presented with a worst case fault current of 50% above the branch circuit breaker rating, the control impedance must not exhibit a voltage drop across itself of more than 2.5 volts AC at 60 Hz.