
| |
ABCG400-11
Part # 66051-XX
|
ABCG500-11
Part # 66060-XX |
ABCG600-11
Part #66072-XX |
ABCG700-11
Part # 66084-XX |
| VA Ratings |
480 |
600 |
720 |
840 |
| Frequency |
60 Hz. |
60 Hz. |
60 Hz. |
60 Hz. |
| BTU/Hr. Output |
115 |
123 |
147 |
143 |
| T.H.D Max. % |
<1% |
<1% |
<1% |
<1% |
| Load Surge Current @ |
|
|
|
|
1/2 cycle |
125 amps |
175 amps |
215 amps |
237 amps |
1 second |
60 amps |
84 amps |
102 amps |
114 amps |
10 seconds |
17 amps |
24 amps |
30 amps |
33 amps |
| Input Voltage |
120 |
120 |
120 |
120 |
| Output Voltage |
120 |
120 |
120 |
120 |
| Output Current |
4.0 amps |
5.0 amps |
6.0 amps |
7.0 amps |
| Efficiency |
93% |
94% |
94% |
95% |
| Voltage Drop No Load to Full Load |
7% |
6% |
6% |
5% |
| Wall mountable* |
|
Yes |
Yes |
Yes |
| Safety Agency Listing |
UL and cUL |
UL and cUL |
UL and cUL |
UL and cUL |
| Shipping Weight (lbs.) |
16 |
18 |
20 |
22 |
|
* When ordering by model number, add "W" to model number above for wall mount option.
POWERVAR Part #
ABCG400-11 - 66051-XX**
ABCG500-11 - 66060-XX**
ABCG600-11 - 66072-XX**
ABCG700-11 - 66084-XX**
**When ordering, add two digit number from below in place of XX to specify receptacle option desired.

Option 1 - Standard Plugs/Receptacles
-02 - 5-15P plug and two 5-15R IG duplex receptacles
-22 - 5-15P plug and two 5-15R IG duplex receptacles
with wallmount
|
Noise Rejection-Isolation: With unit under power and an ANSI/IEEE C62.41Cat. A pulse applied either normal or common mode at the input,
the noise output voltage will be less than 10V normal mode and less than 0.5V common mode in all four quadrants (CM-NM, NM-NM, CM-CM,
NM-CM).
Surge Voltage Withstand Capability: Tested under power to ANSI/IEEE C62.41 Cat. A & B (formerly IEEE587-1980). Cat. A - 6000V @
200 amps, 0.5 µsec risetime, 100 kHZ decay, Cat. B - 6000V @ 500 amps, 0.5 µsec risetime, 100 kHZ decay.
Ground Current Attenuation: Disturbance current coupling into ground conductors is limited to .1% (one tenth of one percent) of the amplitude
of the source disturbance current.
Ground impedance Safety Characteristics: Under worst case capacitive or inductive load conditions, when presented with a worst
case fault current of 50% above the branch circuit breaker rating, the control impedance must not exhibit a voltage drop across itself of more than 2.5
volts AC at 60 Hz.
|