Bomara Associates Logo
Bomara Associates Homepage

North American Standard Conditioners - “D” Case Enclosure

 

 
ABC830-11
Part # 61100-XX
ABC1000-11
Part # 61120-XX
ABC1200-11
Part #61144-XX
ABC1600-11
Part # 61192-XX
ABC2000-11
Part # 61240-XX
VA Ratings
1000
1200
1440
1920
2000
Frequency
60 Hz.
60 Hz.
60 Hz.
60 Hz.
60 Hz.
BTU/Hr. Output
171
205
246
263
328
T.H.D Max. %
<1%
<1%
<1%
<1%
<1%
Load Surge Current @
1/2 cycle
325 amps
375 amps
400 amps
500 amps
500 amps
1 second
156 amps
180 amps
192 amps
240 amps
240 amps
10 seconds
45 amps
52 amps
55 amps
70 amps
70 amps
Input Voltage
120
120
120
120
120
Output Voltage
120
120
120
120
120
Output Current
8.3 amps
10.0 amps
12.0 amps
16.0 amps
20.0 amps
Efficiency
95%
95%
95%
96%
96%
Voltage Drop No Load to Full Load
5%
5%
4%
4%
4%
Wall mountable*

No

No
No
No
No
Safety Agency Listing
UL and cUL
UL and cUL
UL and cUL
UL and cUL
UL and cUL
Shipping Weight (lbs.)
34
38
43
52
63
* When ordering by model number, add "W" to model number above for wall mount option.

Noise Rejection-Isolation: With unit under power and an ANSI/IEEE C62.41Cat. A pulse applied either normal or common mode at the input, the noise output voltage will be less than 10V normal mode and less than 0.5V common mode in all four quadrants (CM-NM, NM-NM, CM-CM, NMCM).
Surge Voltage Withstand Capability: Tested under power to ANSI/IEEE C62.41 Cat. A & B (formerly IEEE587-1980). Cat. A - 6000V @ 200 amps, 0.5 µsec risetime, 100 kHZ decay, Cat. B - 6000V @ 500 amps, 0.5 µsec risetime, 100 kHZ decay.

POWERVAR Part #
ABC830-11 - 61100-XX**
ABC1000-11 - 61120-XX**
ABC1200-11 - 61144-XX**
ABC1600-11 - 61192-XX**
ABC2000-11—61240-XX**


**When ordering, add two digit number from below in place of XX to specify receptacle option desired.


Standard Rear Panel Configuration for Models ABC830-11 through ABC1200-11

 

Option 1 - Standard Plugs/Receptacles
-03 - 5-15P plug and three 5-15R duplex

 

 


Option 2 - Hospital Grade Plugs/Receptacle
-13 - 5-15P plug and two 5-15R duplex hospital grade


Standard Rear Panel Configuration for Model ABC1600-11

 

Option 1 - Standard Plugs/Receptacles
-04 - 5-20P plug and three 5-20R duplex
-24 - 5-20P plug and three 5-20R duplex (cUL)

 

 


Option 2 - Hospital Grade Plugs/Receptacle
-14 - 5-20P plug and three 5-20R duplex hospital grade


Standard Rear Panel Configuration for Model ABC2000-11

 

Option 1 - Twistlock plug with combination of twistlock and standard receptacles
-07 - L5-30P plug, one L5-30R, two 5-20R duplex
-08 - L5-30P plug, one L5-20R, two 5-20R duplex
-27 - L5-30P plug, one L5-30R, two 5-20R duplex (cUL)
-28 - L5-30P plug, one L5-20R, two 5-20R duplex (cUL)


Option 2 - Twistlock plug with standard receptacles
-09 - L5-30P plug and three 5-20R duplex
-29 - Lr-30P plug and three 5-20R duplex (cUL)

 


Option 3 - Twistlock plug and twistlock receptacles
-10 - L5-30P plug and three L5-20R duplex


Special Twistlock Configurations for Models ABC830-11 through ABC1200-11

 

Option 1 - Twistlock plug and twistlock receptacles
-43 - L5-15P plug and three L5-15R duplex


Combination Configurations for Models ABC1000-11 only

 

Option 1 - Twistlock plug with standard receptacles
-05 - L5-20P plug with L5-20R and two 5-20R duplex
-44 - L5-20P plug with L5-20R and two 5-15R duplex


Special Twistlock Configurations for Model ABC1600-11

 

Option 1 - Twistlock plug with standard receptacles
-06 - L5-20P plug and three 5-20R duplex
-26 - L5-20P plug and three 5-20R duplex (cUL)
-09 - L530P plug and three 5-20R duplex

 

 

Option 2 - Twistlock plug with combination of twistlock
and standard receptacles
-25 - L5-20P plug, one L5-20R and two 5-20R duplex
(cUL)



Powervar Home Bomara Homepage Request Information

Bomara Associates Phone: 800.5BOMARA (800.526.6272) Phone: 978.452.2299 Fax: 978.452.1169 3 Courthouse Lane, Chelmsford, MA 01824 USA
email: bobr@bomara.com      web: www.bomara.com