ABCE420-11
54042-02R
|
ABCEG420-11
54042-32R |
ABCE420-11IEC
54042-22R |
| Type |
Standard |
Ground Guard® |
Medical grade (listed to UL60601-1) |
| VA Rating |
|
420 |
420 |
| Watt Rating |
294 |
294 |
294 |
| Inverter Waveform |
Low distortion sine wave |
Low distortion sine wave |
Low distortion sine wave |
| Transfer time |
4 ms. typical |
4 ms. typical |
4 ms. typical |
| Frequency (Note 1) |
60 Hz. |
60 Hz. |
60 Hz. |
| BTU/Hr. Output |
100 |
100 |
100 |
| T.H.D Max. % |
<3% on battery |
<3% on battery |
<3% on battery |
| On Line Efficiency |
93% |
93% |
93% |
| Input Voltage |
120 |
120 |
120 |
| Input Current |
4.1 amps |
4.1 amps |
4.1 amps |
| Output Voltage |
120 |
120 |
120 |
| Output Current |
3.5 amps |
3.5 amps |
3.5 amps |
Input Voltage Range
Without Using Battery |
96-151 volts |
96-151 volts |
96-151 volts |
| Output Regulation (on line) |
+/- 10% |
+/- 10% |
+/- 10% |
| Output Regulation (on battery) |
+/- 5% |
+/- 5% |
+/- 5% |
| Backup time (full/half load) |
6/20 minutes |
6/20 minutes |
6/20 minutes |
| Wall mountable |
Yes |
Yes |
Yes |
| Communications Interface |
DB9, USB |
DB9, USB |
DB9, USB |
| Safety Agency Listing |
UL1778 and cUL1778, RoHS |
UL1778 and cUL1778, RoHS |
UL60601-1 and cUL C22.2 No. 60601-1, RoHS |
| Shipping Weight (lbs.) |
31 |
31 |
31 |
|
Note: ABCE350-11, ABCEG350-11, and ABCE350-11IEC are no longer part of the official Powervar product lineup. They have been supplanted by the corresponding 420VA models listed in the table above.
| |
ABCE350-11
54035-02
|
ABCEG350-11
54035-32 |
ABCE350-11IEC
54035-22 |
| Type |
Standard |
Ground Guard® |
Medical grade (listed to UL60601-1) |
| VA Rating |
|
350 |
350 |
| Watt Rating |
280 |
280 |
280 |
| Inverter Waveform |
Low distortion sine wave |
Low distortion sine wave |
Low distortion sine wave |
| Transfer time |
4 ms. typical |
4 ms. typical |
4 ms. typical |
| Frequency |
60 Hz. |
60 Hz. |
60 Hz. |
| BTU/Hr. Output |
100 |
100 |
100 |
| T.H.D Max. % |
<3% on battery |
<3% on battery |
<3% on battery |
| On Line Efficiency |
93% |
93% |
93% |
| Input Voltage |
120 |
120 |
120 |
| Input Current |
3.2 amps |
3.2 amps |
3.2 amps |
| Output Voltage |
120 |
120 |
120 |
| Output Current |
2.9 amps |
2.9 amps |
2.9 amps |
Input Voltage Range
Without Using Battery |
96-151 volts |
96-151 volts |
96-151 volts |
| Output Regulation (on line) |
+/- 10% |
+/- 10% |
+/- 10% |
| Output Regulation (on battery) |
+/- 5% |
+/- 5% |
+/- 5% |
| Backup time (full/half load) |
6/20 minutes |
6/20 minutes |
6/20 minutes |
| Wall mountable |
Yes |
Yes |
Yes |
| Communications Interface |
DB9 |
DB9 |
NA |
| Safety Agency Listing |
UL1778 and cUL1778 |
UL1778 and cUL1778 |
UL2601-1 and cUL C22.2
No. 601.1 |
| Shipping Weight (lbs.) |
31 |
31 |
31 |
|
Front Panel Controls
• Power On/Off
• Test
• Load Level LED Gauge
• Battery Charge LED Gauge
• Output receptacle status
• Voltage Manager Boost LED
• Voltage Manager Nominal LED
• Voltage Manager Buck LED
• On Battery LED
• Replace Battery LED
• Overload LED |
Additional Model Specific Information
Ground Guard® Models:
Ground Guard models have all the same technical and performance specifications of the standard POWERVAR UPM models. Ground Guard models are equipped with POWERVAR’s patented ground conditioning technology. Ground Guard models prevent the occurrence of ground loops in networked or interconnected system applications. Ground Guard models can be used in lieu dedicated electrical circuits with isolated ground wiring.
Medical Grade Models:
Models with the designation of “-11IEC” have all the same technical and performance specifications of the standard POWERVAR UPM models. These models are equipped with hospital grade plugs and receptacles and have been tested to meet the requirements of UL60601-1 and cUL C22.2 No. 60601-1. These models are not UL or cUL listed for operation at 100 volts.
NOTE 1:
Will operate at 50 Hz when used at 100 volts. When used
at 100 volts, maximum output current still applies. VA rating
is reduced approximately 17%. |
Rear Panel Information and Controls
• 6 foot power cord with NEMA 5-15P plug
• Six (6) NEMA 5-15R receptacles controllable via Communications Manager software in two groups
• Configuration Manager DIP switches
• Communications Manager DB9 port (plus USB port on ABCE420 models)
• Circuit Breaker
• AC Inlet Module
• Battery Enable Plug (also enables cold start on battery)
• Site Wiring Fault LED |
Internal Batteries
• User hot-swappable (see instruction manual)
• Type:
12 volt, 4.5 amp-hour (500 VA)
12 volt, 7 amp-hour (800 VA)
• Quantity: 2 pieces
• Recharge time: 4 hours
|
Environmental
• Temperature:
0 to +40° C (32 to 104°F) Operating
-20 to +60° C (-40 to +140° F) Shipment,
Storage
• Humidity: 5 to 90% non-condensing (Operating,
Shipment, Storage)
• Altitude: 3,000m (10,000 ft.) max. (Operating, Shipment, Storage) |
|
Noise Rejection-Isolation: With unit under power and an ANSI/IEEE C62.41Cat. A pulse applied either normal or common mode at the input,
the noise output voltage will be less than 10V normal mode and less than 0.5V common mode in all four quadrants (CM-NM, NM-NM, CM-CM,
NM-CM).
Surge Voltage Withstand Capability: Tested under power to ANSI/IEEE C62.41 Cat. A & B (formerly IEEE587-1980). Cat. A - 6000V @
200 amps, 0.5 µsec risetime, 100 kHZ decay, Cat. B - 6000V @ 500 amps, 0.5 µsec risetime, 100 kHZ decay.
|