North American Uninterruptible Power Managers
“D” Case Enclosure

 
ABCE1100-11
54110-03*
ABCEG1100-11
54110-33*
ABCE1100-11IEC
54110-23*
Type
Standard
Ground Guard®
Medical grade - listed to
UL2601-1
VA Rating

1100

1100
1100
Watt Rating
715
715
715
Inverter Waveform
Low distortion sine wave
Low distortion sine wave
Low distortion sine wave
Transfer time
4 ms. typical
4 ms. typical
4 ms. typical
Frequency
60 Hz.
60 Hz.
60 Hz.
BTU/Hr. Output
225
225
225
T.H.D Max. %
<3% on battery
<3% on battery
<3% on battery
On Line Efficiency
94%
94%
94%
Input Voltage
120
120
120
Input Current
9.5 amps
9.5 amps
9.5 amps
Output Voltage
120
120
120
Output Current
9.0 amps
9.0 amps
9.0 amps
Input Voltage Range
Without Using Battery
96-151 volts
96-151 volts
96-151 volts
Output Regulation (on line)
+/- 10%
+/- 10%
+/- 10%
Output Regulation (on battery)
+/- 5%
+/- 5%
+/- 5%
Backup time (full/half load)
6/20 minutes
6/20 minutes
6/20 minutes
Wall mountable*
Yes
Yes
Yes
Communications Interface
DB9
DB9
NA
Safety Agency Listing
UL1778 and cUL1778
UL1778 and cUL1778
UL2601-1 and cUL 22.2
No. 601.1
Shipping Weight (lbs.)
65
65
65

 

 
ABCE1440-11
54144-03*
ABCEG1440-11
54144-33*
ABCE1440-11IEC
54144-23*
Type
Standard
Ground Guard®
Medical grade - listed to
UL2601-1
VA Rating

1440

1440
1440
Watt Rating
936
936
936
Inverter Waveform
Low distortion sine wave
Low distortion sine wave
Low distortion sine wave
Transfer time
4 ms. typical
4 ms. typical
4 ms. typical
Frequency
60 Hz.
60 Hz.
60 Hz.
BTU/Hr. Output
250
250
250
T.H.D Max. %
<3% on battery
<3% on battery
<3% on battery
On Line Efficiency
94%
94%
94%
Input Voltage
120
120
120
Input Current
12.0 amps
12.0 amps
12.0 amps
Output Voltage
120
120
120
Output Current
12.0 amps
12.0 amps
12.0 amps
Input Voltage Range
Without Using Battery
96-151 volts
96-151 volts
96-151 volts
Output Regulation (on line)
+/- 10%
+/- 10%
+/- 10%
Output Regulation (on battery)
+/- 5%
+/- 5%
+/- 5%
Backup time (full/half load)
6/20 minutes
6/20 minutes
6/20 minutes
Wall mountable*
No
No
No
Communications Interface
DB9
DB9
NA
Safety Agency Listing
UL1778 and cUL1778
UL1778 and cUL1778
UL2601-1 and cUL 22.2
No. 601.1
Shipping Weight (lbs.)
69
69
69

 

Front Panel Controls
• Power On/Off
• Test
• Load Level LED Gauge
• Battery Charge LED Gauge
• Output receptacle status
• Voltage Manager Boost LED
• Voltage Manager Nominal LED
• Voltage Manager Buck LED
• On Battery LED
• Replace Battery LED
• Overload LED

Additional Model Specific Information

Ground Guard® Models:
Ground Guard models have all the same technical and performance specifications of the standard POWERVAR UPM models. Ground Guard models are equipped with POWERVAR’s patented ground conditioning technology. Ground Guard models prevent the occurrence of ground loops in networked or interconnected system applications. Ground Guard models can be used in lieu dedicated electrical circuits with isolated ground wiring.

Medical Grade Models:
Models with the designation of “-11IEC” have all the same technical and performance specifications of the standard POWERVAR UPM models. These models are equipped with hospital grade plugs and receptacles and have been tested to meet the requirements of UL60601-1 and cUL C22.2 No. 60601-1. These models are not UL or cUL listed for operation at 100 volts.

Rear Panel Information and Controls
• 6 foot power cord with NEMA 5-15P plug
• Six (6) NEMA 5-15R receptacles controllable via Communications
Manager software in three groups
• Configuration Manager DIP switches
• Communications Manager DB9 port*
• Circuit Breaker
• AC Inlet Module
• Start Manger Enable switch (to allow cold starting
UPM on internal battery when no AC power is present
• Site Wiring Fault LED
Internal Batteries
• User hot-swappable (see instruction manual)
• Type - 12 volt, 11 amp-hour (1100 VA)
12 volt, 7 amp-hour (1440 VA)
• Quantity - 2 pieces (1100 VA), 4 pieces (1440 VA)
• Recharge time - 4 hours
Environmental
• Temperature
- 0 - +40° C (32 - 104°F) Operating
- 20 - +60° C (-40 - +140° F) Shipment,
Storage
• Humidity - 5 - 90% non-condensing (Operating,
Shipment, Storage)
• Altitude - 3,000m (10,000 ft.) max. (Operating, Shipment, Storage)

Noise Rejection-Isolation: With unit under power and an ANSI/IEEE C62.41Cat. A pulse applied either normal or common mode at the input, the noise output voltage will be less than 10V normal mode and less than 0.5V common mode in all four quadrants (CM-NM, NM-NM, CM-CM, NM-CM).
Surge Voltage Withstand Capability: Tested under power to ANSI/IEEE C62.41 Cat. A & B (formerly IEEE587-1980). Cat. A - 6000V @ 200 amps, 0.5 µsec risetime, 100 kHZ decay, Cat. B - 6000V @ 500 amps, 0.5 µsec risetime, 100 kHZ decay.