Operation
|
120V |
230V |
| Nominal
Input Voltage |
120
Volts AC (maximum 160 volts) |
230
Volts AC (maximum 290 volts) |
| Input
Voltage Range (for on-line operation) |
90-152
Volts |
176-272 Volts |
| Operating
Frequency (on line) |
50/60
autosensing based on input frequency |
50/60 autosensing based on input frequency |
| Nominal
Output Voltage |
120 VAC |
230 VAC |
| Overload
Capacity |
120%±10%
(3 minutes on line mode, 10 seconds on battery) |
120%±10%
(3 minutes on line mode, 10 seconds on battery) |
| Transfer
Time |
6 ms typical |
6
ms typical |
| On-Battery
Voltage |
120Vrms
±10% |
230Vrms ±10% |
| Operating
Frequency |
50/60
Hz ±3Hz autosensing |
50/60
Hz ±3Hz autosensing |
| Output
Voltage Waveform |
Regulated
step wave |
Regulated
step wave |
| Output
Protection |
Electronically limited |
Electronically limited |
| Input
Protection |
Circuit
breaker |
Circuit
breaker |
| Recharge
Time (to 95%capacity) |
8
hours maximum |
8
hours maximum |
| Lightning
& Surge Protection |
ANSI/IEEE
C62.41 categories A&B, IEC801.4, 801.5 |
ANSI/IEEE
C62.41 categories A&B,
IEC801.4, 801.5 |
| Surge
Energy Capacity |
450
Joules |
450
Joules |
| Efficiency |
>95% on line |
>95%
on line |
| Safety
Certification |
UL1778,
Designed to meet UL497A, CAN/CSAÕC22.2 No.107.1 |
EN50091-1;CE low voltage
directive |
| EMI
Compliance |
FCC Class B |
EN55022,Class B;CE EMC directive |
| Communications |
DB-9,Contact
Closure |
DB-9,Contact Closure |
| Data
Line Protection |
fax/modem,network,telephone |
fax/modem,telephone
only (do not connect network equipment) |
| Indicators |
On line/Utility fail/Overload/Replace battery |
On
line/Utility fail/Overload/Replace battery |
| Audible
Alarms |
Utility
fail/Overload/Replace battery |
Utility fail/Overload/Replace battery |
| Environmental |
| Operating
Temperature |
0-40
°(32 to 104 °F) |
0-40
°(32 to 104 °F) |
| Storage
Temperature |
-15
to 50 °C (5 to 122 °F) |
-15
to 50 °C (5 to 122 °F) |
| Relative
Humidity |
0-95%non-condensing |
0-95%non-condensing |
| Audible
Noise (normal operation) |
<40
dbA |
<40
dbA |
| Altitude |
10,000
ft.(3,000m) |
10,000
ft.(3,000m) |
| |