Bomara Associates Logo Bomara Associates Homepage

Eaton Authorized Power Specialist


Product Page
Specifications
Battery Runtimes

 


 

Powerware 3110

Specification Details

Operation

120V 230V
Nominal Input Voltage 120 Volts AC (maximum 160 volts) 230 Volts AC (maximum 290 volts)
Input Voltage Range (for on-line operation) 90-152 Volts 176-272 Volts
Operating Frequency (on line) 50/60 autosensing based on input frequency 50/60 autosensing based on input frequency
Nominal Output Voltage 120 VAC 230 VAC
Overload Capacity  120%±10% (3 minutes on line mode, 10 seconds on battery) 120%±10% (3 minutes on line mode, 10 seconds on battery)
Transfer Time 6 ms typical  6 ms typical
On-Battery Voltage 120Vrms ±10% 230Vrms ±10%
Operating Frequency 50/60 Hz ±3Hz autosensing 50/60 Hz ±3Hz autosensing
Output Voltage Waveform Regulated step wave Regulated step wave
Output Protection Electronically limited Electronically limited
Input Protection Circuit breaker  Circuit breaker 
Recharge Time (to 95%capacity) 8 hours maximum 8 hours maximum
Lightning & Surge Protection

ANSI/IEEE C62.41 categories A&B, IEC801.4, 801.5

ANSI/IEEE C62.41 categories A&B, IEC801.4, 801.5

Surge Energy Capacity 450 Joules 450 Joules
Efficiency >95% on line >95% on line
Safety Certification  UL1778, Designed to meet UL497A, CAN/CSAÕC22.2 No.107.1  EN50091-1;CE low voltage directive
EMI Compliance FCC Class B EN55022,Class B;CE EMC directive
Communications DB-9,Contact Closure DB-9,Contact Closure
Data Line Protection fax/modem,network,telephone fax/modem,telephone only (do not connect network equipment)
Indicators On line/Utility fail/Overload/Replace battery On line/Utility fail/Overload/Replace battery
Audible Alarms Utility fail/Overload/Replace battery Utility fail/Overload/Replace battery
Environmental 
Operating Temperature 0-40 °(32 to 104 °F) 0-40 °(32 to 104 °F)
Storage Temperature -15 to 50 °C (5 to 122 °F) -15 to 50 °C (5 to 122 °F)
Relative Humidity 0-95%non-condensing 0-95%non-condensing
Audible Noise (normal operation) <40 dbA <40 dbA
Altitude  10,000 ft.(3,000m) 10,000 ft.(3,000m)

Model Selection Guide

 

Voltage  120V  230V 
Model PW3110 300VA PW3110 550VA PW3110 700VA PW3110 300iVA PW3110 550iVA PW3110 700iVA
Part Numbers

05147642-5501

05147644-5501 05147646-5501 05147643-5501 05147645-5501 05147647-5501
Capacity (VA/Watt) 300/180  550/330 700/420 300/180  550/330 700/420
Dimensions
(WxHxL)
in/mm

3.9 x 2.3 x 15.5/
150 x 59 x 393

6.8 x 3.1 x 14.8/
172 x 79 x 376

3.9 x 2.3 x 15.5/
150 x 59 x 393

6.8 x 3.1 x 14.8/
172 x 79 x 376

Weight
(lb/kg)

6.6/3.0

9.2/4.2

9.4/4.3

6.6/3.0

9.2/4.2

9.4/4.3

Input Connection NEMA 5-15P IEC-320 C14 (10amp) recessed socket*
Output Receptacle Quantity & Type  4 (UPS & Surge) + 2 (Surge only) NEMA 5-15R 4 (UPS & Surge) +2 (Surge only) C13 (10 amp)
Typical Runtime: Minutes (Full Load) 4 4 3 4 4 3
*230V models include one jumper cord C13 and C14 type connectors.

 Powerware 3110 Run Times for Typical Applications in Minutes 

Load (VA) 100 150 200 250 300 350 400 450 500 550 600 650 700
300VA

18

13

7

47

4

-

- - - - - - -
550VA

30

22

18

14

11

10

8 6 4 4 - - -
700VA

39

22

17

16

14

13

9 7 6 5 5 3 3

Note: Due to continuing improvement programs specifications are subject to change without notice. Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.  