Bomara Associates Logo Bomara Associates Homepage

Eaton Authorized Power Specialist


Products:
5125 RM
5125

1000-3000 VA Specification Details
Model Guide
Battery runtimes

5000-6000 VA RM Specification Details
Model Guide
Battery runtimes

Rackmount Comparison Charts:

Features
Specifications
Runtime Matrix

 


5125 RM 1000-3000 VA
Two-in-One (Rackmount and Tower Model)


1000-3000 VA Model


Specification Details

Electrical Input

1000-3000 VA

Nominal Voltage

120, 208, 230 and 240Vac;
See Model Selection Guide for user-selectable volages

Input Voltage Ranges (for user-selectable voltages)

Low voltage: 77-152V; High voltage: 154-288V

Operating Frequency

50/60Hz, Auto-sensing

Frequency Range

46-65Hz

Electrical Output
On Utility Voltage Regulation

-10% to +6% of nominal

On Battery Voltage Regulation

 ±5% RMS

Voltage Wave Shape (on battery)

 Sine Wave

Output Protection

 Short circuit protection

Battery
Battery Type Sealed, lead-acid; maintenance free
Battery Run time  See Battery Run Times Table
Battery Replacement Hot-swappable internal batteries and external batteries modules
Recharge Time <3 hours to 90% usable capacity
Start-On-Battery Allows start of UPS without utility input
General
Diagnostics Full System self-test on power up
UPS Bypass No Bypass, Internal Bypass
Transfer Time 2-4ms typical
Dimensions and Weights  See Model Selection Guide
Overload (normal operation) 110% overload, shutdown after 3 minutes.
 150% overload, shut down 10 cycles
110% overload for 30 seconds short circuit protected
Communications
User Interface

Front Control Panel

Audible Alarms

For various UPS alarm conditions, including: On Battery, Low Battery, Overload, UPS fault

Network Transient Protector

 UL 497 A, in/out jacks RJ45 (high voltage models network protection) &
 RJ11  (low voltage models modem protection)

REPO Port

 Meets NEC code 645-11 intent and UL requirements

X-Slot Interface

 RS-232 Single Serial Card (standard),
other options available: See available Options Chart

Cable

6-foot communications cable included

Power Management Software

Powerware Software Suite CD-ROM (bundled with UPS)

Environmental 
Safety Certifications

 UL; cUL; NOM; C-Tick; CE mark

EMC Compliance

FCC Part 15, EN50091-2, Class A for 2.2 KVA and RM; Class B for 1000 and 1500VA tower models

FCC Part 15, EN50091-2, Class A

Operating Temperature

 0 to 40º C (32 to 104º F)

Storage Temperature

-15 to 50º C (5 to 122º F)

Relative Humidity

0% to 95% non-condensing

Lightning & Surge Protection 

ANSI/IEEE C62.41 (IEEE 587), IEC61000-4-5

Surge Energy Rating

480 Joules

Audible Noise

Less than 40 dBA typical

 Altitude 

3000m (10,000 ft) without derating

Note: Specifications are subject to change without notice due to continuing product improvement programs.

 

Model Selection Guide

Model
Number1

Power 
Rating (VA/Watt)

Input/
Output Voltage
(Vac)2

Input Connection

Output Receptacles4

Dimensions HxWxD (in/mm)

Weight (lb/kg)

Two-in-One Form Factor Models5 (North America)
PW5125
1000 RM
1000/900 120 5-15P,
6 ft line cord
(6) 5-15R 3.5 x 17.0 x 19.4/
89 x 432 x 494
61.0/27.67
PW5125
1500 RM
1440/1340 120 5-15P,
6 ft line cord
(6) 5-15R 3.5 x 17.0 x 19.4/
89 x 432 x 494
61.0/27.67
PW5125
2400 RM
2400/2250   120 L5-30P,
(12' attached)
 (1) L5-30R,
(6) 5-15R
3.5 x 19.0 x 24.5/
89 x 482.6 x 622.3
89.0/40.40
PW5125
3000 RM 
2880/2700 120 L5-30P,
(12' attached) 
(1) L5-30R,
(6) 5-15R
3.5 x 19.0 x 24.5/
89 x 482.6 x 622.3
89.0/40.40
Two-in-One Form Factor Models5 (International)
PW5125
1000i RM 
1000/900  230 IEC-320-10A,
inlet3
(6) IEC-320-10A (C13) 3.5 x 17.0 x 19.4/
89 x 432 x 494
61.0/27.67
PW5125
1500i RM
1500/1340  230 IEC-320-10A,
inlet3
(6) IEC-320-10A (C13) 3.5 x 17.0 x 19.4/
89 x 432 x 494
61.0/27.67
PW5125
2400i RM
2400/2250  230 IEC-309 16A P,
(12' attached) 
(1) IEC-320-16A (C19)
(9) IEC-320-10A (C13)
3.5 x 19.0 x 24.5/
89 x 482.6 x 622.3
89.0/40.40
PW5125
3000g RM6
3000/2700 200-240 IEC-320-16A,
receptable
(1) IEC-320-16A (C19)
(9) IEC-320-10A (C13)
3.5 x 19.0 x 24.5/
89 x 482.6 x 622.3
89.0/40.40
PW5125
3000e RM7
3000/2700  230 IEC-320-16A,
receptacle
(1) IEC-320-16A (C19)
(9) IEC-320-10A (C13)
3.5 x 19.0 x 24.5/
89 x 482.6 x 622.3
89.0/40.40
PW5125
3000i RM8
3000/2700  230 IEC-309 16A P,
(12' attached) 
(1) IEC-320-16A (C19)
(9) IEC-320-10A (C13)
3.5 x 19.0 x 24.5/
89 x 482.6 x 622.3
89.0/40.40
PW5125
3000j RM9
2400/2250 100 L5-30P
(12' attached)
(1) L5-30R
(6) 5-15R
3.5 x 19.0 x 24.5/
89 x 482.6 x 622.3
89.0/40.40

1. 50/60 automatic frequency selection.
2. 120 V models are 110 V,120 V,127 V user-selectable.230 V models are 220 V,230 V,240 V user-selectable.208 V models are 208 V,220 V,230 V,240 V user-selectable.
3. Includes(2) each IEC interconnect cables.
4. 1000-1500VA models divided into (2) Load Segments (receptacle groups).  2200-3000VA models are divided into (3) Load Segments (receptacle groups).
5. Unit fits in standard 19-inch racks. Mounting kits are sold separately.
6. g-model carries agency listing cUL; C-Tick; TUV/GS; CE.
7. e-model carries agency listing CE mark only.
8. i-indicating international model, 230 V.
9. j -indicating Japanese model, 100 V.

 

Powerware 5125 Battery Run Time Chart (in minutes full load/half load)*

VA Standard Internal
Batteries
1 EBM 2 EBMs 3 EBMs 4 EBMs
Two-in-One Form Factor
1000 

7/19

33/68

58/120

82/166 105/214
1500 

5/13

23/57

49/161

73/172 96/205
2400 

7/19

35/73

60/124

85/177 110/229
3000 

5/15

25/61

49/103

69/146 90/190

*Up to 4 EBMs can be connected to 1000-3000VA models. EBM run times include internal batteries.
Run time chart provides typical information. Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.

 

Available Options

Order Number Description
05141562-0021 4 post rackmount kit (fits 19-inch racks)
05146726-5501 2 post rackmount kit (fits 19-inch racks)
05146871-5501 3-Slot seismic mounting kit (1000 / 1500 RM models only)
05146875-5501 5-Slot seismic mounting kit (1000 / 1500 RM models only)
05146447-5502 X-Slot Multi-Server Card
05146508-5501 X-Slot USB Card
1018460 X-Slot Relay Card
IPK-0330 X-Slot SNMP/Web Adapter Card
103002510-5501 X-Slot Modbus Card
05146288-5501 X-Slot SNMP card (used with Onlinet software only)
05146519-001 Powerpass distribution module (1000 / 1500 RM models only)


Powerware Home
Bomara Homepage
Request Information

Bomara Associates Phone: 800.5BOMARA (800.526.6272) Phone: 978.452.2299 Fax: 978.452.1169 3 Courthouse Lane, Chelmsford, MA 01824 USA
email: bobr@bomara.com      web: www.bomara.com
Serving the marketplace for over 35 years