The Powerware 9125 PowerPass
is designed to enhance the
reliability and flexibility of the
Powerware 9125. The PowerPass
enables you to upgrade or
replace the UPS while continuously
providing power to
your protected equipment. The
PowerPass also provides surge
protection for the critical loads
if your UPS is not present and
provides surge protection for
your laser printer without taxing
the UPS.
The PowerPass also works in
conjunction with Eaton's power
management software to allow
orderly shutdown and startup of
individual load segments. This
enables you to keep key pieces of
equipment running, and power
down non-critical equipment to
save UPS battery power.
The PowerPass features six
receptacles plus a laser receptacle
on 1500 VA and below models
and connects directly to the back
of the UPS. It works with both the
tower and rack mount configurations
of the Powerware 9125.
| Model |
120V |
120V |
240V |
| Part Number |
05146520-001 |
05146519-002 |
0514519-002 |
| Capacity (VA) |
700 - 150 |
2000 |
700 - 2000 |
| Nominal Input Voltage |
120V, 16A |
120V, 16A |
240V |
| Operating Frequency |
50/60 Hz |
50/60 Hz |
50/60 Hz |
| Dimensions (WxDxH) |
11.0” x 4.5” x 3.5” (27.9 x 11.4 x 8.9cm) |
11.0” x 4.5” x 3.5” (27.9 x 11.4 x 8.9cm) |
11.0” x 4.5” x 3.5” (27.9 x 11.4 x 8.9cm) |
| Weight |
2.5 lb (1.1 kg) |
2.5 lb (1.1 kg) |
2.5 lb (1.1 kg) |
| Surge Suppression |
180V MOVs across input L and N;
100 joule, 6500A peak current rating
320V MOVs each across L to G and N to G;
160 joule; 6500A peak current rating |
180V MOVs across input L and N;
100 joule, 6500A peak current rating
320V MOVs each across L to G and N to G;
160 joule; 6500A peak current rating |
320V MOVs across input L1 and L2;
160 joule, 6500A peak current rating |
| Electrostatic Discharge |
Withstands 25 kV |
Withstands 25 kV |
Withstands 25 kV |
| Input Connection to PowerPass |
5-15R mates with UPS
5-15P power cord |
5-20R mates with UPS
5-20P power cord
|
IEC-320 plug mates with UPS IEC-320 receptacle |
| Input Connection to UPS |
(6) 5-15R; (1) 5-15R
for laser printer
(unprotected)
|
(6) 5-15R |
(6) IEC 320-C13;
(1) IEC 320-C13 for laser printer
(unprotected)
|
| Output Receptacles |
(2) 5-15P connect to
UPS AC output |
(2) 5-15P connect to
UPS AC output |
2) IEC 320-C13 plugs connect to
UPS AC output |
| UPS AC Output to PowerPass (Plug) |
(2) 5-15P connect to
UPS AC output |
(2) 5-15P connect to
UPS AC output |
(2) IEC 320-C13 plugs connect to
UPS AC output |
| Agency Approvals |
UL 1778; CSA C22.2 No. 107.1;
ANSI/IEEE C62.41-1991, NEMKO |
UL 1778; CSA C22.2 No. 107.1;
ANSI/IEEE C62.41-1991, NEMKO |
UL 1778; CSA C22.2 No. 107.1;
IEC 950 and EN50091-1 |
| Environmental |
|
|
|
| Operating Temperature |
0 to 40ºC (32 to 104°F) |
0 to 40ºC (32 to 104°F) |
0 to 40ºC (32 to 104°F) |
| Storage Temperature |
-20 to 60ºC (-4 to 140°F) |
-20 to 60ºC (-4 to 140°F) |
-20 to 60ºC (-4 to 140°F) |
| Relative Humidity |
5-96% non-condensing |
5-96% non-condensing |
5-96% non-condensing |