Product snapshot
Power rating: 2500–3000 VA
Voltage: 120–240 Vac
Frequency: 50–60 Hz
Configuration: Plug-and-play
and hardwire
UPS is on top
PPDM is on bottom

 

The Eaton® PowerPass® power distribution module (PPDM) is designed to enhance the flexibility of the Eaton 9130 3 kVA UPS. The PPDM enables you to upgrade or replace the UPS while continuously providing power to your critical equipment. With the 9130 UPSs, Eaton delivers a best-in-class power solution for maximum system availability and peace of mind. Use the questions in this guide to correctly specify a PPDM.

Features

  • Maintenance Bypass Switch to perform maintenance or upgrade your UPS without powering down your critical systems
  • Expanded receptacle and hardwire configurations
  • Galvanic isolation for increased protection
  • Step-down transformer allows power output of 120V
    and a combination of 120V and 208–240V

 

Model Chart (1)
Style Number Description
Input Voltage (Vac)
Output Voltage (Vac)

Input Connection (2)
Output Receptacles
Dimensions
(H x W x D, in)
Weight
(lb)

EPPDMG3000R-2U-13 (3)
103007535-6591
PPDM1-HV-US-P2 3 kVA
208–240
120 IEC320-C20
(1) L5-30R & (6) 5-20R
3.5 (2U) x 17.0 x 23.9
76
EPPDMG3000R-2U-HW3 (3)
103007536-6591
PPDM1-HV-US-HW
3 kVA (ROHS)
208–240
208–240/120
Hardwire
Hardwire
3.5 (2U) x 17.0 x 23.9
76
EPPDML3000R-2U-HW4 (4)
103007537-6591
PPDM2-LV-US-HW
3 kVA (ROHS)
120 120 Hardwire
Hardwire
3.5 (2U) x 17.0 x 23.9
20
EPPDML3000R-2U-44 (4)
103006843-6591
PPDM2-LV-US-P1
3 kVA
120 120 L5-30P
(1) L5-30R & (6) 5-20R
3.5 (2U) x 17.0 x 23.9
20
1. All models fit in 19-inch rack enclosures and come with a four-post rail kit.
2. Connection cables to the UPS are included with the PPDM; use the input cord from the UPS as input to the PPDM, except for hardwire units.
3. These PPDMs work with the following 9130 models: PW9130G2500R-XL2UEU, PW9130G3000R-XL2UEU and PW9130i3000R-XL2U.
4. This PPDM works with the following 9130 models: PW9130L2500R-XL2U and PW9130L3000R-XL2U.

 

Technical Specifications

  PDM1 Models PDM2 Models
Overcurrent Protection Fuses
Two 20A Fuses
PDM1–HV–US: Two 20A fuses
PDM1–HV–US–P1 and PDM1–HV–US–HW:
15A circuit breaker
PDM2–LV–US–P1: Two 20A fuses
Isolation Transformer
3 kVA: 208–240V Switch Selectable
120/208–240V Output
None
Bypass Switch 30A, 600V 30A, 600V
Operating Temperature 0ºC to 40ºC (32ºF to 104ºF) 0ºC to 40ºC (32ºF to 104ºF)
Relative Humidity 5–95% noncondensing 5–95% noncondensing
Safety Conformance
UL 1778
CAN/CSA C22.2, No. 107.1, 107.2; NOm–019–SCFI
UL 1778
CAN/CSA C22.2, No. 107.1, 107.2
Agency Markings UL, cUL UL, cUL
EMC (Class A) EMC (Class A) EN 50091–2, FCC Part 15 Class A, ICES–003
Specifications typical and subject to change without notice

Notice: All prices are subject to change without notice.

Powerware Home
Bomara Homepage
Request Information

Bomara Associates Phone: 800.5BOMARA (800.526.6272) Phone: 978.452.2299 Fax: 978.452.1169 3 Courthouse Lane, Chelmsford, MA 01824 USA
email: bobr@bomara.com      web: www.bomara.com
Serving the marketplace for over 35 years