| Power |
| Rating |
8kVA, 10 kVA, 12 kVA, 15 kVA at0.9 power factor |
| Topology |
True double-conversion online UPS |
| Output connection |
Hardwired |
| Electrical Input |
| Nominal input voltage |
200 - 240 VAC with Neutral or with Optional Input Transformer |
| Input voltage range |
-15%, +10% from nominal at 100% load
without depleting battery |
| Operating frequency |
50/60 Hz (45 to 65 Hz) |
| Input power factor |
0.99 typical |
| Input current distortion |
5% THD |
| Electrical Output |
| Nominal output voltage |
Output Voltages are user-selectable 100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacement |
| Output voltage regulation |
±1% Static; ±5% dynamic at 100%
resistive load change, <1 ms response time |
| Efficiency |
90% typical |
| Battery |
| Battery Type |
9Ah sealed Valve-Regulated lead Acid (VRLA), maintenance-free, minimum 3-year float service life at 77 degree F, 192 Vdc (96 cells per string) |
| Battery Run Time |
See Battery Run Time Chart |
| Battery Replacement |
Must be replaced by qualified service technician |
| Charger |
Service configurable, 0.5-34A per string, with overall maximum of 34A (limited by current input). Default: 3.4A per String |
| Start-On-Battery |
Allows start of UPS without utility input |
| General |
| Diagnostics |
Full system self-test at startup |
| UPS Bypass |
Automatic on overload or UPS failure |
| Dimensions and Weights |
See Model Selection Table |
| Overload (Normal Operation) |
101-110% for 10 minutes, 111-125% for 60 seconds, 126-149% for 5 seconds, >150% for 300 milliseconds |
| Communications |
| LCD-display |
Graphical LCD with blue backlight |
| LEDs |
(4) LEDs for notice and alarm |
| Audible Alarms |
Yes |
| Communication Ports |
(1) RS-232, (1) relay contact, (1) REPO,
(2) environmental input |
| Communication Slot |
(2) X-Slot communication bays |
| Power Management Software |
Bundled Software Suite CD |
| Environmental |
| Operating Temperature |
0ºC to +40ºC, +45ºC with 7.5% derating;
Batteries recommended max. +25ºC |
| Storage Temp |
-15°C to +40°C |
| Relative Humidity |
0–90%, non condensing |
| Audible Noise |
<56dBA at 1 meter distance, typical loads |
| Altitude |
< 1000m at +40°C, < 3000m at +25°C |
| Certification |
| Safety Certifications |
NOM-019-SCFI-1993, UL 1778, CSA C22.2, No. 107.3; EN 5502 Class A (CISPR22 Class A) and IEC 60950; IEC 62040-1-1 |
| EMC Compliance |
IEC 62040-2, FCC Part 15, ICES-003, VCCI |
| Quality |
ISO 9001: 2000 and ISO 14001:1996 |
| Markings |
UL, cUL, CSA, CE, NOM-NYCE |