Powerware
9305

Special Features
- Uninterruptible
power protection against power failures, power sags,
power surges, brownouts, line noise, high voltage
spikes, frequency variation, ups, switching transients
and harmonic distortion
- Advanced
Battery Management (ABM™)
- doubles battery service life
- LanSafe v.5 compatible - an easy and complete power management
solution
- Silent
- Ideal for server rooms
- DC
Expert - accurate remaining back-up time indication
|
 |
Specification
Overview
- Double
Conversion Topology ensures trouble-free
output.
- 3-Phase
UPS with 3-Phase Bypass ensures balanced loading of
the mains also in bypass.
- Widest
Input Voltage and Frequency Window in the Market means
longer battery life and increased reliability.
- Continuous
100% Unbalanced Loading means that loads can be started
and stopped without worrying about balancing.
- On-site
Upgrading Possible means that the customer can later
increase the load without buying a new UPS.
- Onput
Power Factor of 0.96 means smaller fuses are used, ensuring
a more cost effective installation.
- Selectable
Output Voltage ensures excellent output voltage properties
for demanding situations
- Communication
Interfaces allow serial communication with local computers
and remote computers via modem. The relay interface allows
building monitoring.
- LanSafe v.5 Compatibility for an easy and complete power management
solution.
- Sentinel
FORS Compatibility for remote monitoring by service
centers.
- PowerVision®
Compatibility for top of the line monitoring and trend
analysis software for monitoring all components from UPSs
and generators to utility and power distribution (the whole
power train).
- Programmable
Building Alarms gives flexibility in meeting site/application
specific demands.
- Advanced
Battery Management (ABM™). Since the UPS
charges the batteries only when necessary, the temperature
of the batteries is lower and corrosion is lessened, allowing
a 50% longer life time for the batteries. On-line remote
monitoring during rest mode, safe test means that the UPS
doesn't switch to battery mode and the load will not crash
in case of faulty battery. Test results and Advanced Battery
Management™ status availibility via local and remote monitoring
ensures early warning for the customer and the service.
In case of faulty battery, the early warning gives enough
time for the customer to change the battery bank before
it becomes useless
- DC
Expert™ "learns" the battery and takes aging
into account, ensuring an accurate remaining back-up time
indication.
- Size.
The unit is small, light, equipped with castors and has
a very small foot print making it ideal for a server room.
It is easy to move and install.
- Robust
Design makes this UPS ideal for industrial environments.
- Front
Access for installation and service
- Ease
of Use. LEDs indicate the status of the UPS and there
is one-switch operation.
- Battery
Start means that it can be started also when the
main is missing.
- Silent
makes this USP ideal for server rooms
7.5
- 15 kVA
- Double
Conversion Topology ensures trouble
free output.
- 3-Phase
UPS with 3-Phase Bypass ensures balanced loading of
the mains also in bypass.
- Widest
Input Voltage and Frequency Window in the Market means
longer battery life and increased reliability.
- Continuous
100% Unbalanced Loading means that loads can be started
and stopped without worrying about balancing.
- On-site
Upgrading Possible means that the customer can later
increase the load without buying a new UPS.
- Onput
Power Factor of 0.96 means smaller fuses are used, ensuring
a more cost effective installation.
- Selectable
Output Voltage ensures excellent output voltage properties
for demanding situations.
- Communication
Interfaces allow serial communication with local computers
and remote computers via modem. The relay interface allows
building monitoring.
- LanSafe v.5 Compatibility for an easy and complete power management
solution.
- Sentinel
FORS Compatibility for remote monitoring by service
centers.
- PowerVision®
Compatibility for top of the line monitoring and trend
analysis software for monitoring all components from UPSs
and generators to utility and power distribution (the whole
power train).
- Advanced
Battery Management (ABM™). Since the UPS
charges the batteries only when necessary, the temperature
of the batteries is lower and corrosion is lessened, allowing
a 50% longer life time for the batteries. On-line remote
monitoring during rest mode, safe test means that the UPS
doesn't switch to battery mode and the load will not crash
in case of faulty battery. Test results and Advanced Battery
Management™ status availibility via local and remote monitoring
ensures early warning for the customer and the service.
In case of faulty battery, the early warning gives enough
time for the customer to change the battery bank before
it becomes useless.
- DC
Expert™ "learns" the battery and takes aging
into account, ensuring an accurate remining back-up time
indication.
- Size.
The unit is small, light, equipped with castors and has
a very small foot print making it ideal for a server room.
It is easy to move and install.
- Robust
Design makes this UPS ideal for industrial environments.
- Ease
of Use. LEDs indicate the status of the UPS and there
is one-switch operation.
- Battery
Start means that it can be started also when the mains
is missing.
- Silent
makes this UPS ideal for server rooms.
|
|
|
|