Powerware Index > Series 9 Index > Eaton 9E
Eaton 9E is a 3 Phase UPS Double Conversion 20-30KVA and 40-60kVA ModelsThe Eaton® 9E UPS gives IT managers an easy way to manage the power in their data center, without having to worry about cost, space or downtime. Developed specifically for IT managers, the 9E confronts typical data center problems head on. It addresses ROI, energy costs, remote management, and efficiency…giving you more time to focus on other important data center issues. Key features and benefits:Lower operating costs through energy-efficient performance
• Delivers up to 98% efficiency Maximum runtime through internal batteries Occupy less floor space with a compact footprint Installation and warranty Intelligent Power Manager Software Applications• Small-to-medium data centers AccessoriesExtended Battery Cabinet (EBC) Integrated Accessory Cabinet (IAC) Integrated Transformer Cabinet (ITC) Wall-Mount Bypass 9E model selection guide
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Part Number | Power Rating(VA/Watts) | Input Plug | Output Receptacles | List Price |
| 9E (20-30 KVA) Models for External Runtime & External Maintenance Bypass | ||||
| 9EB02AA60001000 | 20000 / 16000 | Hardwired | Hardwired | $16,398 |
| 9EB03AA60001000 | 30000 / 24000 | Hardwired | Hardwired | $18,170 |
| 9E (20-30 KVA) Models for External Runtime & Internal Maintenance Bypass | ||||
| 9EB02AA60101000 | 20000 / 16000 | Hardwired | Hardwired | $17,948 |
| 9EB03AA60101000 | 30000 / 24000 | Hardwired | Hardwired | $19,720 |
| 9E (20-30 KVA) Models with Internal Runtime & External Maintenance Bypass | ||||
| 9EA02AA61001000 | 20000 / 16000 | Hardwired | Hardwired | $21,826 |
| 9EA03AA61001000 | 30000 / 24000 | Hardwired | Hardwired | $23,598 |
| 9E (20-30 KVA) Models with Internal Runtime & Internal Maintenance Bypass | ||||
| 9EA02AA61101000 | 20000 / 16000 | Hardwired | Hardwired | $23,376 |
| 9EA03AA61101000 | 30000 / 24000 | Hardwired | Hardwired | $25,148 |
| 9E (40-60 KVA) Models for External Runtime & External Maintenance Bypass | ||||
| 9EB04AA60001000 | 40000 / 32000 | Hardwired | Hardwired | $26,504 |
| 9EB06AA60001000 | 60000 / 48000 | Hardwired | Hardwired | $33,991 |
| 9E (40-60 KVA) Models for External Runtime & Internal Maintenance Bypass | ||||
| 9EB04AA60101000 | 40000 / 32000 | Hardwired | Hardwired | $29,504 |
| 9EB06AA60101000 | 60000 / 48000 | Hardwired | Hardwired | $36,504 |
| 9E (40-60 KVA) Models with Internal Runtime & External Maintenance Bypass | ||||
| 9EB04AA61001000 | 40000 / 32000 | Hardwired | Hardwired | $38,540 |
| 9EB06AA61001000 | 60000 / 48000 | Hardwired | Hardwired | $43,027 |
| 9E (40-60 KVA) Models with Internal Runtime & Internal Maintenance Bypass | ||||
| 9EB04AA61101000 | 40000 / 32000 | Hardwired | Hardwired | $41,540 |
| 9EB06AA61101000 | 60000 / 48000 | Hardwired | Hardwired | $46,027 |
| Certifications | |
| Safety Certifications | UL 1778 |
| EMI Standards | EN55022/EN55024 |
| EMC Compliance | IEC 62040-2 |
| Quality | ISO 9001: 2000 and ISO 14001:1996 |
| Markings | UL, cUL |
| Power |
|
| Rating | 20 kVA/16 kW, 30 kVA/24 kW, 40 kVA/32 kW and 60 kVA/48 kW |
| Topology | Double-conversion online UPS |
| Electrical Input |
208/120V, 4 wire or 220/127V, 4 wire |
| Input Voltage Range |
-15%, +20% from nominal (208V) at 100% load without depleting battery |
| Operating Frequency |
50/60 Hz (40 to 72 Hz) |
| Input Power Factor |
>0.99 typical |
| Input Current Distortion |
5% THD |
| Electrical Output |
|
| Nominal Output Voltage |
208/220, 3/4 wire |
| Output Voltage Regulation |
±1% Static; ±5% dynamic at 100% resistive load change, <20 ms response time |
| Battery |
|
| Battery Type |
9 Ah, sealed, lead-acid, maintenance-free |
| Battery Runtime |
20 kVA - 21 minutes, 30 kVA - 12 minutes, (100% Load) 40 kVA - 10 minutes, 60 kVA - 5 minutes |
| Battery Replacement |
Field-replaceable |
| Charging Method |
ABM (Cyclic) or float |
| General |
|
| Efficiency |
Up to 98% High-efficiency mode Up to 92% Double-conversion |
| UPS Bypass |
Automatic on overload or UPS failure |
| Dimensions |
20-30 kVA - 20.9 x 31.5 x 53.5 (530 x 800 x 1360) W x D x H, in (mm) 40-60 kVA - 23.6 x 31.5 x 74.9 (600 x 800 x 1880) |
| Weights |
20-30 kVA - 1049.4 lbs, 476 kg 40-60 kVA - 1499.1 lbs, 680 kg |
| Overload |
150% for 40 ms / 125% for 30 seconds 110% for 10 min |
| Communications |
|
| Display | Graphical LCD with blue backlight |
| LEDs | (4) LEDs for notice and alarm |
| Audible Alarms |
Yes |
| Communication Ports |
(1) RS-232, (1) REPO |
| Communication Slot |
(2) Mini-slot communication bays |
| Environmental |
|
| Operating Temperature |
0ºC (32ºF) to +30ºC (86ºF); Batteries recommended max. +25ºC (77ºF) |
| Storage Temperature | -25ºC (-13ºF) to +55ºC (131ºF) without batteries +15ºC (59ºF) to +25ºC (77ºF) with batteries |
| Relative Humidity | 5–95%, non-condensing |
| Audible Noise | < 64 dBA at 1 meter (noise less room) typical |
| Altitude | < 1000m at +30°C (86ºF) |
| Certifications |
|
| Safety Certifications |
UL60950 |
| EMI Standards |
EN55022/EN55024 |
| EMC Compliance |
IEC 62040-2 |
| Quality |
ISO 9001: 2000 and ISO 14001:1996 |
| Markings | UL, cUL |
| 20 kVA | 30 kVA | 40 kVA | 60 kVA | |||
| 1 EBC |
42 minutes |
26 minutes |
26 minutes - 4 String |
43 minutes - 6 String |
14 minutes - 4 String |
26 minutes - 6 String |
| 2 EBC |
102 minutes |
62 minutes |
62 minutes - 8 String |
104 minutes - 12 String |
37 minutes - 8 String |
62 minutes - 12 String |
Lowest total cost of ownership The 9E is the clear choice if you're seeking to maximize your return on investment (ROI). Delivering the lowest TCO of any UPS in its class, the 9E offers a unique blend of energy, space and installation savings. The 9E can decrease your TCO by more than $85,000* over its 12-year lifespan when compared to current competitive offerings. |
* Energy calculation based against a 60 kVA UPS operating at 91% efficiency (kW/hr $0.10, Cooling Ratio 80%, 12 yrs). Space saving calculation based against a 60 kVA UPS with an 11.8 ft 2 footprint using $150/ft 2 per year. |
||||||||||
Energy-efficient design
The 9E is capable of achieving up to a 98% efficiency rating,
making it one of the most energy-efficient UPSs in its class —
and it still provides maximum load protection. Unlike most high efficiency
UPSs, the 9E:
• Provides surge suppression for the load
• Detects the location of faults (utility or load) and takes the appropriate action
• Switches to double-conversion operation in less than 4 ms
The 9E will save more than $71,292 in electricity and cooling
costs over the life of the product when compared to a 60 kVA
UPS operating at 91% efficiency.
Compact footprint
Smaller than any comparable competitor by up to 35%, the 9E allows you to better utilize floor space for revenue-producing equipment. It also puts money back in your pocket that would otherwise be used to build, maintain and condition space for larger power/support equipment. The ongoing annual maintenance cost for office and data center space in the United States is estimated to be between $90 and $224 per square foot. The savings realized from the 9E's smaller footprint quickly adds up.
| 60 kVA | Width (in) | Depth (in) | Height (in) | Footprint (sq/ft) |
| Eaton 9E | 23.6 | 31.5 | 74.9 | 5.2 |
| A | 45.2 | 30.0 | 72.0 | 9.4 |
| B | 48.0 | 35.5 | 81.5 | 11.8 |
| C | 56.8 | 38.0 | 78.5 | 15.0 |
Installation Reduced installation costs mean the 9E can be up and |
Serviceability The 9E is easily and quickly serviced to provide the highest |
Software
Eaton's Intelligent Power® Software Suite incorporates two important applications for ensuring quality power and uptime: monitoring and management of power devices across the network combined with automatic, graceful shutdown when faced with an extended power outage. Intelligent Power Manager supervisory software lets you monitor and manage multiple power and environmental devices across the network from a single interface, giving you up-to-the-minute information on the status of power in your network. It also works seamlessly with VMware's vCenter Server™ and vMotion™, as well as Microsoft's SCVMM™ and Live Migration. Intelligent Power Protector protection software provides graceful, automatic shutdown of network devices during a prolonged power disruption, preventing data loss and saving work-in-progress. As part of Eaton's power network management system, these two applications work together to deliver comprehensive power management and protection.
Notice: All prices are subject to change without notice.
| Request
Information |
email: bobr@bomara.com web: www.bomara.com
![]()