Eaton ePDU catalog numbering system

 

Eaton ePDU
Product Line Overview

Monitored ePDUs - 0U
ePDU Types Monitored ePDUs - 1U/2U
Understanding ePDU Technologies Advanced Monitored ePDUs
ePDU software management Switched ePDUs
Basic ePDUs - 0U Eaton Automatic Transfer Switches
Basic ePDUs - 1U Rack Power Module
FlexPDUs and Hot Swap Maintenance Bypass The IEC Advantage
Hot Swap Maintenance Bypass Power cables and accessories
Temperature & Humidity Sensors Space-saving mounting options

 

Broad product portfolio
Eaton offers the largest selection of rack mounted power distribution units available on the market, we call these Eaton® ePDUs®.
Our complete suite of products is designed specifically to help you meet rapidly escalating requirements.

Top seller ePDUs
In this catalog you will find Eaton's top-selling ePDUs, units which we stock for high availability and quick turn around. These units tend
to be the most popular and will provide solutions to key data center needs. For detailed technical specifications for all of our top-selling ePDUs.

Build-to-order ePDUs
Eaton also has build-to-order units, which you can find in the Industrial Catalog and on eaton.com/epdu. Components of these units are
stocked at the factory to provide competitive lead times for these products.

Custom ePDUs
It is important to note that Eaton also offers custom capabilities for rack power distribution. Our engineering expertise allows us to build
any type of configuration for our customers should there not be a top seller or build-to-order unit available to meet the desired solution.
These units have different lead times, pricing structure and warranty offerings.

High Density Power Solutions
Eaton offers a number of ePDUs that will meet your high power density needs. We offer both rack mount, and vertical mount three-phase
models ranging from 50A, 60A to even 80A input capacities. These sophisticated units allow an entire rack of equipment to be powered
from a single power cord input.

24/7 Reliability through circuit breakers
ePDUs use individual UL-rated branch circuit breakers that protect load segments (outlet groups), ensuring that an overloaded circuit does
not affect other load segments, therefore increasing reliability. Typically, circuit breakers have flat rockers or are fully shrouded to prevent
accidental on/off operation.

Rugged design for optimal performance and quick installation
Eaton ePDUs are designed to meet global safety standards. These units are engineered with rugged construction, have flexible mounting
options, and multiple features ensuring the highest quality and customer satisfaction. Eaton engineers unique solutions for the most
power intense environments.

    Back To Top

 

Eaton ePDU catalog numbering system
Eaton's smart style numbers help you understand our numbering system. Follow the example below to see what the letters and numbers
mean within this ePDU catalog. Please note that this numbering scheme represents the majority of our part numbers, but not all.

Eaton Catalog

 

ePDU technologies
Eaton's ePDU technologies satisfy the demand of every data center. Eaton ePDUs offer single and dual chassis, five technology options,
the broadest power range in the market and the ability to manufacture custom ePDUs. They also offer an arrangement of outlets (number
and type) for every region.
Eaton ePDUs are distinguished for their quality, dependability and versatility. All products are designed for a specific application with an
emphasis on safety and reliability. The Eaton line includes an extensive range of vertical, zero 0U products, which do not occupy server
space in racks, as well as 1U and 2U formats. Environmental monitoring options are also available.

Feature
Basic (BA)
Monitored
Network (MI)
Advanced Monitored (AM)
Switched
(SW)
Automatic
Transfer (AT)
Rugged Construction
x x x x x
Horizontal Products
x x   x x
Vertical Products
x x x x  
Local Current Display
  x x x  
Current Monitoring Type
  Section
Outlet
Section
 
Voltage Monitoring
      x  
Serial Interface
      x  
Ethernet Interface
  x x x  
Environmental Sensors
  x*
x x  
*Available on some models

 

    Back To Top

ePDU Types

 

EPDU BABasic (BA) – rugged construction and flexible mounting options

Designed for reliable and cost effective power distribution, Basic ePDUs have the form factor and
receptacle choices to meet the needs of the demanding data center architect. With power levels
ranging from 1.4 kW all the way to 17 kW, Eaton has the right Basic ePDU for any application.

 

 

EPDU FlexFlexPDUs and Hot Swap Maintenance Bypass

The Eaton FlexPDUs are designed to provide flexible output receptacle options from a single UPS.
These products have a three-foot input cord, enabling them to be mounted in close proximity to
the UPS.
Ideal for maintenance and UPS replacement, the Eaton HotSwap Maintenance Bypass facilitates
hot-swappable UPS replacement without shutting down equipment connected to the UPS.

 

EPDU MIMonitored Network (MI)

Eaton Monitored ePDUs provide remote monitoring of the current draw of individual sections via
Ethernet or Serial communication. This capability, combined with state-of-the-art software allows
you to aggregate the information from hundreds of ePDUs in one location. All Monitored ePDUs also
include the Easy-Read digital LED ammeter for easy start-up and provisioning of servers.

 

EPDU AMAdvanced Monitored (AM) – Current Monitoring Per Outlet

Designed for high-density, mission-critical server applications, the Advanced Monitored ePDUs
provide maximum power for both standard and blade servers by allowing you to monitor at the
outlet level. Employing multiple configurations, the Easy-Read digital ammeter and remote power
management with clearly labeled circuits, these ePDUs ensure easy management and monitoring for
current requirements and future expansion.

 

EPDU SWSwitched (SW) – individual outlet switching and sequencing

Designed for data centers needing remote site management, the Switched ePDUs provide remote
power monitoring of both voltage and current. The current is also displayed on a local two-digit
current meter. These units also monitor both temperature and humidity. The Switched ePDUs employ
multiple configurations, available in 0U and 2U rack mount, and 42" or 66" vertical lengths. They
also provide individual on/off/reboot control of up to 36 receptacles. The control interface is highly
customizable with multiple functions and flexibility to send either SNMP traps or e-mail alerts.

 

EPDU ATEaton Automatic Transfer Switches (AT)

Designed for switching non phase synchronized AC power sources, the automatic transfer switch
ePDUs intelligent circuitry monitors both inputs, providing a fast switch transfer from primary to
secondary source power critical equipment without interruption. These ePDUs assure the highest
level of redundancy to mission critical applications.

 

    Back To Top

 

Understanding ePDU Technologies

 

Why monitor?
The unique monitoring function of Eaton ePDUs allows you to remotely monitor the current draw of individual outlets or sections over
a network. This, combined with state-of-the-art software, allows the user to aggregate the information from hundreds of ePDUs in one
location. All monitored ePDUs also include the Easy-Read digital LED ammeter for easy start-up and provisioning of servers. This feature allows remote monitoring of current for capacity planning and energy management.

Key features and benefits
• Access circuit-level and ePDU-level information worldwide
• Get a global view across your ePDUs from any PC or server with Intelligent Power Manager software
• Receive warnings and alarms remotely

 

Advanced Monitoring

Advanced monitoring allows you to monitor down to the individual outlet

Key features:
• High-density configurations reduce enclosure space requirement
• Fuse-less design significantly reduces reset time
• UL Listed (UL489) branch circuit breakers meet UL60950-1 edition requirements
• Easy-Read digital ammeter reduces local monitoring time (auto scroll capability)
• True RMS ammeter provides accurate power measurement
• Multi-purpose mounting improves installation flexibility
• Isolation hardware improves product grounding
• High-grade components increases product reliability and fault tolerance
• Clearly labeled circuits simplify load balancing

400 volt solution
Eaton 400V ePDUs limit energy loss through transformers by avoiding the 480-208 volt conversion. These units use European standard,
three-phase 400 volt phase-to-phase – 230 volt phase to neutral - replacing 208 volt phase-to-phase in the US. Operating power supplies
at 230 volt versus 208 volt typically increases power supply efficiency.

400V ePDUs also distribute almost twice the power on the same copper to achieve multiple reductions. Eaton offers a unique power
distribution solution for 400 volt applications. These applications include
• Containerized data centers
• Customers looking for global standard
• Progressive data centers looking for cost reductions and efficiency gains
You can find 400V ePDUs featured in the Monitored and Switched sections of this catalog.

400V ePDU part numbers (for reference)
Monitored
• VPC2864-3861
• VPC2864-3862

Switched
• IPV70U1-EP1-09L
• IPV70U2-EP1-09L

    Back To Top

 

ePDU software management
Eaton offers a number of software management tools for you based on the number of ePDUs you need to manage.

Software
Quantity Best
Supported
Type of Software
Application
Cost
Web Browser / E-mail
1-25
Included requires web browser
Data Closet Small Network Stand Alone
Included
SNMP
1-1000
Integrates to
3rd Party Software
Small to Large
Enterprise
Low-High
IPM
1-200
Eaton software free to try
Small to Medium
Enterprise
Low-Medium
PowerXpert
1-1000
Eaton enterprise solution
Facility or Large
Enterprise
High

Web Browser / E-mail Alerts
Every network connected ePDU comes standard with built in web server and e-mail alert capability. This allows connection to any ePDU
using a standard web browser to configure, monitor and control. If your network allows connection to an SMTP server, the ePDU can be
configured to send e-mail alerts using a POP 3 e-mail account.

SNMP
Every network connected ePDU supports SNMP alerts and has a standard MIB available for integration into 3rd party software solutions.
SNMP supports full monitoring and control with read/write capability for all major variables.

Intelligent Power Manager (IPM)Software
Ideal for monitoring and managing multiple power and
environmental devices, Intelligent Power Manager software from
Eaton delivers a global view across your network from any PC with
an Internet browser, Microsoft's SCVMM™ or VMWare's vCenter™
dashboard. The software allows for one point monitoring of ePDU,
UPS and environmental sensors. The software monitors alarms,
logs current readings and environmental sensors on ePDU. The
software features auto-discovery of connected devices and export
to spreadsheet for report manipulation.
In the event of a power interruption, the software will also alert
VMWare's vMotion™ or Microsoft's Live Migration™ to move your
virtual machines to an available server for zero downtime.

PowerXpert
Ideal as a facility enterprise solution, PowerXpert supports the full offering of Eaton's electrical products and offers support for third
party products. PowerXpert monitors alarms, logs current readings and environmental sensors on ePDU. There is a Web based dashboard
view that allows you to drill down to a specific ePDU. Using the optional reporting package, customized power utilization reports can
be generated.
PowerXpert also allows you to customize the conditions under which alarms are triggered and can run deployment validation tools during
installation so all key setup requirements are automatically validated.

    Back To Top

 

Basic ePDUs - 0U
Eaton Basic ePDUs are designed for reliable and cost-effective power distribution.

Catalog Number
Style Number
Input Plug
Breaker
Max kW
Function
Cord
(ft)
Orientation
Receptacles
Dimensions
(H x W x D, in)
Click For Image
ePBZ73 ePBZ73 5-15P None 1.44 BA 15 0U (18) 5-15R 48 x 1.5 x 1.5  
ePBZ75 ePBZ75 5-15P None 1.44 BA 15 0U (14) 5-15R 24 x 1.5 x 1.5  
ePBZ77 ePBZ77 5-15P None 1.92 BA 15 0U (24) 5-20R 60 x 1.5 x 1.5  
ePBZ98
ePBZ98
5-15P
15A
1.44 BA
6 0U
(18) 5-15R
48 x 1.5 x 1.5
 
ePBZ89
ePBZ89
C14
None
1.44 BA
6 0U
(16) C13
28 x 1.9 x 2.2
ePBZ89
ePBZ87 ePBZ87 C14 20A(1) 3.3 BA 9 0U (16) C13 1.9 x 28 x 2.2  
ePBZ97
ePBZ97
5-20P
(1) 20A
1.92 BA
6 0U
(24) 5-20R
48 x 1.5 x 1.5
ePBZ97
ePBZ71 ePBZ71 L5-20P None 1.92 BA 15 0U (30) 5-20R 72 x 1.5 x 1.5  
ePBZ72 ePBZ72 L5-20P None 1.92 BA 15 0U (18) 5-20R 48 x 1.5 x 1.5  
ePBZ74 ePBZ74 L5-20P None 1.92 BA 15 0U (14) 5-20R 24 x 1.5 x 1.5  
ePBZ96
ePBZ96
L5-20P
(1) 20A
1.92 BA
6 0U
(24) 5-20R
48 x 1.5 x 1.5
 
ePBZ90 ePBZ90 L5-30P (2) 20A 2.88 BA 15 0U (24) 5-20R 40 x 1.9 x 2.1  
PW103BA0U257
V70BC2-N-SL-009
L5-30P
(2) 20A
2.88 BA
9 0U
(24) 5-20R
66 x 2.0 x 1.89
 
ePBZ93
ePBZ93
L6-20P
(1) 20A
3.33 BA
6 0U
(20) C13, (4) C19
42 x 1.9 x 2.4
ePBZ93
PW103BA0U237
V70NB4-N-SL-009
L6-20P
None
3.33 BA
9 0U
(24) C13, (4) C19
66 x 2.0 x 1.89
 
ePBZ80 ePBZ80 L6-30P (2) 20A 4.99 BA 10 0U (30) C13, (6) C19 52.9 x 1.9 x 2.2  
ePBZ92
ePBZ92
L6-30P
(2) 20A
4.99 BA
6 0U
(20) C13, (4) C19
42 x 1.9 x 2.2
 
PW105BA0U239
V70BF5-N-SL-009
L6-30P
(2) 20A
4.99 BA
9 0U
(24) C13, (4) C19
66 x 2.0 x 1.89
PW105BA0U239
PW105BA0U412
LPC1224-1P
L14-30P
(6) 15A
4.99 BA
6 0U
(12) 5-15R
10 x 7.75 x 3.0
 
PW306BA0U241
VPC2864-A2-3846
L21-20P
None
5.76 BA
9 0U
(30) 5-20R
66 x 2.0 x 1.89
 
PW306BA0U244
VPC2864-3850
L21-20P
None
5.76 BA
9 0U
(36) C13, (6) C19
66 x 2.0 x 1.89
 
PW306BA0U246
VPC2864-3856
L21-20P
None
5.76 BA
9 0U
(18) 5-20R, (6) L6-20R
66 x 2.0 x 1.89
PW306BA0U246
PW309BA0U409
VPC3106-C2-15
L21-30P
(3) 20A
8.65 BA
9 0U
(24) 5-20R
70 x 2.0 x 3.8
 
PW314BA0U251
VPC2864-3858
CS8365P
(2) 20A (1) 30A
14.4 BA
9 0U
(24) C13, (4) C19, (2) L6-30R
66 x 2.0 x 1.89
 
PW314BA0U253
VPC2864-3853
CS8365P
(3) 20A
14.4 BA
9 0U
(30) C13, (6) C19
66 x 2.0 x 1.89
PW314BA0U253

 

    Back To Top

 

Basic ePDUs - 1U

Catalog Number
Style Number
Input Plug
Breaker
Max kW
Function
Cord
(ft)
Orientation
Receptacles
Dimensions
(H x W x D, in)
Click For Image
ePBZ83 ePBZ83 5-15P (1) 12 A 1.44 BA 15 1U (12) 5-15R 1.7 x 17.3 x 2.3  
ePBZ86 ePBZ86 5-15P (2) 20A 2.88 BA 15 1U (12) 5-15R 40 x 1.9 x 2.1  
PW101BA1U140
T982A1-N-SS-009
5-15P
(1) 15A
1.44 BA
9 1U
(12) 5-15R
1.75 x 19 x 7
PW101BA1U140
ePBZ85 ePBZ85 5-20P None 1.92 BA 10 1U (12) 5-20R 1.7 x 17.3 x 2.3  
PW102BA1U158
T982A2-N-SS-009
5-20P
(1) 20A
1.92 BA
9 1U
(12) 5-20R
1.75 x 19 x 7
 
ePBZ82 ePBZ82 L5-20P None 1.92 BA 15 1U (12) 5-20R 1.7 x 17.3 x 2.3  
ePBZ99
ePBZ99
L5-20P
(1) 20A
1.92 BA
6 1U
(12) 5-20R
1.75 x 19 x 2.4
ePBZ99
PW102BA1U159
T982A2-N-SL-009
L5-20P
(1) 20A
1.92 BA
9 1U
(12) 5-20R
1.75 x 19 x 7
 
ePBZ78 ePBZ78 L5-30P (2) 20A 2.88 BA 15 1U (20) 5-20R 1.7 x 17.0 x 3.5  
ePBZ84 ePBZ84 L5-30P (2) 20A 2.88 BA 10 1U (10) 5-20R 1.7 x 17.0 x 3.5  
PW103BA1U190
T982C2-N-SL-009
L5-30P
(2) 20A
2.88 BA
9 1U
(12) 5-20R
1.75 x 19 x 7
 
ePBZ88
ePBZ88
C20
None
3.33 BA
6 1U
(10) C13, (2) C19
1.72 x 19 x 2.4
ePBZ88
PW103BA1U405
TPC2104
C20
(1) 20A
3.33 BA
9 1U
(16) C13
1.75 x 19 x 7
 
ePBZ95
ePBZ95
L6-20P
None
3.33 BA
6 1U
(12) C13, (1) C19
1.72 x 19 x 2.4
ePBZ95
PW103BA1U191
T982B3-N-SL-009
L6-20P
(1) 20A
3.33 BA
9 1U
(12) C13
1.75 x 19 x 7
 
ePBZ79 ePBZ79 L6-30P (2) 20A 4.99 BA 15 1U (16) C13, (4) C19 1.7 x 17.0 x 5.1  
ePBZ91 ePBZ91 L6-30P (2) 20A 4.99 BA 10 1U (10) C13 1.7 x 17.0 x 3.5  
ePBZ94
ePBZ94
L6-30P
(2) 20A
4.99 BA
6 1U
(6) C19
1.72 x 19 x 2.4
ePBZ94
PW103BA1U406
TPC2105-1-107
L6-30P
(2) 15A
3.33 BA
9 1U
(16) C13
1.75 x 19 x 7
 
PW105BA1U163
T982F3-N-SL-009
L6-30P
(2) 15A
4.99 BA
9 1U
(12) C13
1.75 x 19 x 7
PW105BA1U163
PW105BA1U192
T982F4-N-SL-009
L6-30P
(2) 15A
4.99 BA
9 1U
(8) C13, (4) C19
1.75 x 19 x 7
 
PW105BA1U404
T982G1-N-SL-009
L14-30P
(2) 15A
4.99 BA
9 1U
(12) 5-15R
1.75 x 19 x 7
 
PW314BA1U193
T17C19250-3-009
CS8365P
(6) 20A
14.4 BA
9 1U
(6) C19
1.75 x 19 x 7
PW314BA1U193
    Back To Top

FlexPDUs and Hot Swap Maintenance Bypass

 

FlexPDUs
Eaton FlexPDUs increase power distribution from a single UPS.
• 3 foot cord allows easy connection close to UPS without cable clutter
• Mounting bracket attaches directly to UPS
• Mounting bracket allows for vertical, 1U or UPS attachment

 

 

 

Catalog Number
Style Number
Input Plug
Breaker
Max kW
Function
Cord
(ft)
Orientation
Receptacles
Dimensions
(H x W x D, in)
Click For Image
EFLX1500R-PDU1U
58,015 5-15P
None
1.44 BA
3 1U
(12) 5-15R, (1) C19
1.7 x 17.3 x 2.3
EFLX1500R-PDU1U
EFLX2000R-PDU1U
58,020 5-20P
None
1.92 BA
3 1U
(12) 5-20R
1.7 x 17.3 x 2.3
 
EFLX2000R-PDU1UL
58,021 5-20P
None
1.92 BA
3 1U
(5) L5-20R
2.0 x 17.3 x 3.0
EFLX2000R-PDU1UL
EFLXI3000R-PDU1UIEC
68,438 C20 Inlet
(2) 20A
3.33 BA
3 1U
(12) C13, (1) C19
1.7 x 17.3 x 2.3
EFLXI3000R-PDU1UIEC
Includes C19 to C14 and C19 to C20 jumper cables

 

Hot Swap Maintenance Bypass
Hot Swap MBPs enable easy UPS replacement without interruption to the connected load. Placing the HotSwap MBP in bypass mode
provides utility power to equipment while the UPS is being serviced.

Catalog Number
Style Number
Input Plug
Breaker
Max kW
Function
Cord
(ft)
Orientation
Receptacles
Dimensions
(H x W x D, in)
Click For Image
EHBPL1500R-PDU1U
58,115 5-15P
None
1.44 BA
8 2U
(6) 5-15R
2.1 x 17.3 x 3.8
EHBPL1500R-PDU1U
EHBPL2000R-PDU1U
58,120 5-20P
None
1.92 BA
8 2U
(6) 5-15R
2.1 x 17.3 x 3.8
 
EHBPL3000R-PDU1U
58,130 L5-30P
(2) 20A
2.88 BA
3.3 2U
(5) 5-20R
2.1 x 17.3 x 3.8
 

 

    Back To Top

 

Monitored ePDUs - 0U
Eaton Monitored ePDUs all users to remotely monitor the current draw of the unit and individual sections.

Catalog Number
Style Number
Input Plug
Breaker
Max kW
Function
Cord
(ft)
Orientation
Receptacles
Dimensions
(H x W x D, in)
Temperature Monitoring Click For Image
PW101MI0U233
V70NA1-N-SS-109
5-15P
None
1.44 MI
9 0U
(24) 5-15R
66 x 2.0 x 1.89
   
PW102MI0U234
V70NA2-N-SS-109
5-20P
None
1.92 MI
9 0U
(24) 5-20R
66 x 2.0 x 1.89
   
PW102MI0U235
V70NA2-N-SL-109
L5-20P
None
1.92 MI
9 0U
(24) 5-20R
66 x 2.0 x 1.89
   
PW103MI0U236
V70BC1-N-SL-109
L5-30P
(2) 15A
2.88 MI
9 0U
(24) 5-15R
66 x 2.0 x 1.89
   
PW103MI0U238
V70NB4-N-SL-109
L6-20P
None
3.33 MI
9 0U
(24) C13, (4) C19
66 x 2.0 x 1.89
   
PW105MI0U240
V70BF5-N-SL-109
L6-30P
(2) 20A
4.99 MI
9 0U
(24) C13, (4) C19
66 x 2.0 x 1.89
   
PW105MI0U255
V70BJ3-N-SL-109
L14-30P
(2) 20A
4.99 MI
9 0U
(24) C13, (4) C19, (4) 5-20R
66 x 2.0 x 1.89
  PW105MI0U255
PW306MI0U242
VPC2864-A2-3847
L21-20P
None
5.76 MI
9 0U
(30) 5-20R
66 x 2.0 x 1.89
 
PW306MI0U243
VPC2864-3848
L21-20P
None
5.76 MI
9 0U
(24) C13, (3) C19, (6) 5-20R
66 x 2.0 x 1.89
 
PW306MI0U408
VPC2864-A1
L21-20P
None
5.76 MI
9 0U
(30) 5-15R
66 x 2.0 x 1.89
 
PW306MI0U245
VPC2864-3851
L21-20P
None
5.76 MI
9 0U
(36) C13, (6) C19
66 x 2.0 x 1.89
 
PW306MI0U247
VPC2864-3857
L21-20P
None
5.76 MI
9 0U
(18) 5-20R, (6) L6-20R
66 x 2.0 x 1.89
PW306MI0U247
PW306MI0U416
VPC2864-3436
L21-20P
None
5.76 MI
10 0U
(42) C13
66 x 2.0 x 1.89
 
PW309MI0U248
VPC2864-3849
L21-30P
(3) 20A
8.64 MI
9 0U
(24) C13, (3) C19, (6) 5-20R
66 x 2.0 x 1.89
PW309MI0U248
PW309MI0U250
VPC2864-3726
L21-30P
(3) 15A
8.64 MI
9 0U
(36) C13
66 x 2.0 x 1.89
PW309MI0U250
PW309MI0U256
VPC2864-3852
L21-30P
(3) 20A
8.64 MI
9 0U
(30) C13, (6) C19
66 x 2.0 x 1.89
PW309MI0U256
PW314MI0U252
VPC2864-3859
CS8365P
(2) 20A (1) 30A
14.4 MI
9 0U
(24) C13, (4) C19, (2) L6-30R
66 x 2.0 x 1.89
 
PW314MI0U254
VPC2864-3854
CS8365P
(3) 20A
14.4 MI
9 0U
(30) C13, (6) C19
66 x 2.0 x 1.89
 
PW317MI0U222
VPC3690
IEC 60309
460P9W
(6) 20A
17.3 MI
7 0U
(12) C13, (12) C19
66 x 4 .0 x 1.89
PW317MI0U222
VPC2864-3861   400V
VPC2864-3861
IEC309
516P6W
None
14.4 MI
9 0U
(30) C13, (6) C19
66 x 2 x 1.83
 
VPC2864-3862   400V
VPC2864-3862
IEC309
532P6W
(3) 20A
14.4 MI
9 0U
(30) C13, (6) C19
66 x 2 x 1.83
 
These units have available temperature monitoring

Optional Sensors

SENSOR - T1-10
(1) Temperature Sensor, 10' Cable

SENSOR - T2-10
(2) Temperature Sensor,
10' Cable each

    Back To Top

 

Monitored ePDUs - 1U/2U

Catalog Number
Style Number
Input Plug
Breaker
Max kW
Function
Cord
(ft)
Orientation
Receptacles
Dimensions
(H x W x D, in)
Temperature Monitoring Click For Image
PW101MI1U221
T982A1-N-SS-109
5-15P
(1) 15A
1.44 MI
9 1U
(12) 5-15R
1.75 x 19 x 7
   
PW101MI1U403
T982A2-F-SS-109
5-20P
(1) 20A
1.92 MI
9 1U
(12) 5-20R
1.75 x 19 x 7
   
PW102MI1U160
T982A2-N-SL-109
L5-20P
(1) 20A
1.92 MI
9 1U
(12) 5-20R
1.75 x 19 x 7
  PW102MI1U160
PW103MI1U161
T982C2-N-SL-109
L5-30P
(2) 20A
2.88 MI
9 1U
(12) 5-20R
1.75 x 19 x 7
   
PW103MI1U162
T982B3-N-SL-109
L6-20P
(1) 20A
3.33 MI
9 1U
(12) C13
1.75 x 19 x 7
  PW103MI1U162
PW105MI1U164
T982F3-N-SL-109
L6-30P
(2) 15A
4.99 MI
9 1U
(12) C13
1.75 x 19 x 7
   
PW105MI1U165
T982F4-N-SL-109
L6-30P
(2) 15A
4.99 MI
9 1U
(8) C13, (4) C19
1.75 x 19 x 7
  PW105MI1U165
PW105MI2U402
PC3783
L6-30P
(2) 20A
4.99 MI
15 2U
(20) C13
3.44 x 19 x 7
 
PW317MI2U141
PC3623
IEC 60309
460P9W
(6) 20A
17.29 MI
10 2U
(12) C19
3.5 x 19 x 13.5
PW317MI2U141
These units have available temperature monitoring

Optional Sensors

SENSOR - T1-10
(1) Temperature Sensor, 10' Cable

SENSOR - T2-10
(2) Temperature Sensor,
10' Cable each

 

    Back To Top

 

Advanced Monitored ePDUs
Eaton Advanced Monitored ePDU provides maximum power for both standard and blade server. Additionally this technology provides
outlet level monitoring for capacity planning and energy management.

Catalog Number Style Number
Input Plug
Breaker
Max kW
Function
Cord
(ft)
Orientation
Receptacles
Dimensions
(H x W x D, in)
Temperature Monitoring Click For Image
PW105AM0U411 VPC3695-3794
L6-30P
(2) 20A
5.76 AM
9 0U
(14) C13, (2) C19
66 x 2.0 x 3.5
PW105AM0U411
PW309AM0U410 VPC3695-3792
L21-30P
(3) 20A
8.65 AM
9 0U
(21) C13, (3) C19
66 x 2.0 x 3.5
PW309AM0U410

Optional Sensors

SENSOR - T1-10
(1) Temperature Sensor, 10' Cable

SENSOR - T2-10
(2) Temperature Sensor,
10' Cable each

    Back To Top

 

Switched ePDUs
Eaton switched ePDU provides remote power monitoring of both voltage and current and provides outlet level control for on/off/reboot.

Catalog Number
Style Number
Input Plug
Breaker
Max kW
Function
Cord
(ft)
Orientation
Receptacles
Dimensions
(H x W x D, in)
Temperature Monitoring Click For Image
PW101SW0U224
IPV70A1-EP1-09S
5-15P
None
1.44 SW
9 0U
(16) 5-15R
66 x 2.0 x 1.89
PW101SW0U224
PW102SW0U150
IPV42A2-EP1-09L
L5-20P
None
1.92 SW
9 0U
(8) 5-15R
42 x 2.0 x 1.89
PW102SW0U150
PW102SW0U151
IPV70A5-EP1-09L
L5-20P
None
1.92 SW
9 0U
(24) 5-15R
66 x 2.0 x 1.89
 
PW103SW0U152
IPV70C5-EP1-09L
L5-30P
(2) 15A
2.88 SW
9 0U
(16) 5-15R
66 x 2.0 x 1.89
PW103SW0U152
PW103SW0U153
IPV70B2-EP1-10L
L6-20P
None
3.33 SW
10 0U
(24) C13
66 x 2.0 x 1.89
PW103SW0U153
PW105SW0U154
IPV70F3-EP1-09L
L6-30P
(2) 15A
4.99 SW
9 0U
(16) C13
66 x 2.0 x 1.89
PW105SW0U154
PW306SW0U155
IPV70K1-EP1-09L
L21-20P
None
5.76 SW
9 0U
(24) 5-15R
66 x 2.0 x 1.89
 
PW306SW0U156
IPV70M1-EP1-09L
L21-20P
None
5.76 SW
9 0U
(24) C13
66 x 2.0 x 1.89
 
PW309SW0U178
IPV70R1-EP1-09L
L21-30P
(3) 20A
8.64 SW
9 0U
(24) C13
66 x 2.0 x 3.5
PW309SW0U178
PW317SW0U400
IPV70T2-EP1-12L
IEC 60309
460P9W
(6) 20A
17.29 SW
12 0U
(18) C13, (6) C19
66 x 2 x 4
 
PW317SW0U401
IPV70T1-EP1-12L
IEC 60309
460P9W
(6) 20A
17.29 SW
12 0U
(12) C13, (12) C19
66 x 2 x 4
 
IPV70U1-EP1-09L
IPV70U1-EP1-09L
IEC309 516P6W
None
14.4 SW
9 0U
(24) C13
66 x 2 x 1.83
 
IPV70U2-EP1-09L
IPV70U2-EP1-09L
IEC309 516P6W
None
14.4 SW
9 0U
(18) C13, (6) C19
70 x 2 x 4
 
PW103SW2U413*
IPC3401-NET
C20
(1) 20A
3.33 SW
0 1U
(8) C13
1.75 x 19 x 9.5
   
PW103SW2U414*
IPC3402-NET
C20
(1) 20A
3.33 SW
0 1U
(8) 5-15R
1.75 x 19 x 9.5
   
PW105SW2U415
IPC36F4N2USW15L
L6-30P
(2) 20A
4.99 SW
9 2U
(20) C13, (4) C19
3.5 x 19 x 9.5
 
PW105SW2U223
IPC36F4N2USW09L
L6-30P
(2) 20A
4.99 SW
9 2U
(20) C13, (4) C19
3.5 x 19 x 9.5
 
* Model does not have local or remote current or voltage monitoring, but features local on/off buttons in addition to remote switching.

 

    Back To Top

 

Eaton Automatic Transfer Switches
The Eaton eATS ePDUs automatically transfer power from the primary source to a secondary source.

Catalog Number
Style Number
Input Plug
Breaker
Max kW
Function
Cord
(ft)
Orientation
Receptacles
Dimensions
(H x W x D, in)
Click For Image
PWATSS515002
T2235-A1-NNB09S
(2) 5-15P
None
1.44 AT
9 1U
(8) 5-15R
1.72 x 19 x 7
PWATSS515002
PULSTS1400R-1U
66,027 (2) 5-15P
None
1.44 AT
6 1U
(6) 5-15R
1.72 x 19 x 9.8
 
PWATSS520003
T2235-A2-NNB09S
(2) 5-20P
None
1.92 AT
9 1U
(8) 5-20R
1.72 x 19 x 7
 
PWATSL520004
T2235-A2-NNB09L
(2) L5-20P
None
1.92 AT
9 1U
(8) 5-20R
1.72 x 19 x 7
 
PWATSL530005
T2235-C2-CNB09L
(2) L5-30P
(1) 20A
2.88 AT
9 1U
(8) 5-20R
1.72 x 19 x 9.5
 
PWATSL530007
T2235-3369
(2) L5-30P
(1) 30A
2.88 AT
9 1U
(1) L5-30R
1.72 x 19 x 7
PWATSL530007
PWATSSC20001
T2235-AB-NNBC20
(2) C20
None
1.92 AT
NA
1U
(8) C13, (1) C19
1.72 x 19 x 7
PWATSSC20001
PULSTS16AMPR-1U
66,028 (2) C20
None
3.33 AT
6 1U
(6) C13, (1) C19
1.72 x 19 x 9.8
 
PWATSL630006
T2235-F3-CNB09L
(2) L6-30P
(2) 15A
4.99 AT
9 1U
(12) C13
1.72 x 19 x 7
PWATSL630006
PWATSL630008
T2235-3358
(2) L6-30P
None
4.99 AT
9 1U
(1) L6-30R
1.72 x 19 x 7
 
    Back To Top

 

Rack Power Module
The Rack Power Module (RPM) delivers up to 36 kW (hard wire option required, BladeUPS connector limits to 12kW) of power to loads
of various voltages, power cords and layouts. The 3U RPM can be deployed in the same rack with the UPS and IT equipment; there's no
need for a dedicated infrastructure rack. The resulting architecture has fewer cables to manage, fewer distribution points to monitor and
greater flexibility for IT personnel to make changes without an electrician. This unit is typically deployed with the Eaton BladeUPS units.

Features:
• Provides plug-and-play primary distribution of power from a three-phase input source to
secondary power distribution devices
• Serves data center loads with various voltages, power cord configurations and layouts
• Distributes three-phase power to 12 poles, grouped into two sets of six poles, with choice of
output receptacle types
• "Power Equalizer" LED display gives quick visual indication of each circuit's load, reducing
possibility of overloads and breakers tripped off line
• Load information available from the front of the rack, no need to check individual power strips
in the rear of the cabinet (hot isle)
• Branch circuit monitoring option allows easy load monitoring over the network
• Installs in only 3U of space in EIA 19" rack or enclosure (or wall mounted), all hardware included
• Enables customer installation and changes without the services of a licensed electrician

 

RPM

 

ePDU plugs and receptacles
Standard NEMA Plugs

5-15r 5-15p 5-20R 5-20P
l5-20r l5-20p L5-30r l5-30P
6-15r_6-15p l6-20r l6-20p
l6-30r l6-30p l14-30r l14-30p
iec-320-c13 iec-320-c14 iec-320-c19 iec-320-c20
iec-309-16a iec-309-32a  
R indicates receptacle
P indicates plug
L indicates locking plug or receptacle
    Back To Top

 

The IEC Advantage:

The IEC 60320 and IEC 60309 connectors described below are the most commonly specified. The IEC connector system is used throughout the world. By utilizing an Eaton ePDU with the IEC connectors, you can attach the correct cable assembly for British, Australian, Continental European, North American and many other cable/connector configurations. This allows you to purchase and inventory one ePDU for shipment anywhere in the world.

iec 60309

 

General ePDU Environmental Specifications

• Operating Temperature is 0 to 50˚ C
• Storage Temperature is -40 to 70˚ C
• Altitude Maximum 10,000 ft.
• Relative Humidity is 95% max non-condensing

    Back To Top

 

Power cables and accessories

By turning to Eaton, you can enjoy one-stop shopping for a full range of power quality and power distribution needs, including power
cables. The Eaton cable portfolio includes nearly two dozen choices in three product categories including adapters, jumpers and splitters.
All Eaton power cables are tested and certified for use with Eaton products, such as ePDUs, rack power modules (RPMs) and UPSs—
proven to deliver the reliability and service life needed for the most rigorous data center applications.

Splitter Cables Adapter cables
cbl139CBL139 Splitter Cable
L14-30R to (2) L6-30R (4 ft/2 ft)
010-0032010-0032:
C14 to NEMA 5-15R
125V, 15A
1 foot, 16 AWG/3-wire
010-9334010-9334:
NEMA 5-15P to C19
125V, 15A straight blade
8-foot, 14 AWG/3-wire
cbl143CBL143 Splitter Cable
L14-30R to (2) L5-30R (4 ft/2 ft)
010-9335010-9335:
NEMA 5-20P to C19
125V, 20A straight blade
8-foot, 12 AWG/3-wire
010-9336010-9336:
NEMA 6-15P to C19
250V, 15A straight blade
8-foot, 14 AWG/3-wire
cbl148CBL148 Splitter Cable
L14-20R to (2) L5-20R (4 ft/2 ft)
010-9337010-9337:
NEMA 6-20P to C19
250V, 20A straight blade
8-foot, 12 AWG/3-wire
010-9338010-9338:
NEMA L5-15P to C19
125V, 15A twist-lock
8-foot, 14 AWG/3-wire

cbl149CBL149 Splitter Cable
L21-30R to (3) L5-30R (4 ft/2 ft/1 ft)

010-9339010-9339:
NEMA L5-20P to C19
125V, 20A twist-lock
8-foot, 12 AWG/3-wire
010-9340010-9340:
NEMA L6-15P C19 to
250V, 15A twist-lock
8-foot, 14 AWG/3-wire

cbl150

CBL150 Splitter Cable
L21-20R to (3) L5-20R (4 ft/2 ft/1 ft)

010-9341010-9341:
NEMA L6-20P to C19
250V, 20A twist-lock
8-foot, 12 AWG/3-wire
Jumper Cables
010-0025010-0025: 8-foot
010-0027: 6-foot
010-0028: 4-foot
010-0029: 2-foot
C14 to C13
  010-9342010-9342:
C20 Male to C19
20A
8-foot, 12 AWG/3-wire
010-9365010-9365
C14 to C19, 8-foot
010-0034010-0034:
8-foot, 12 AWG/3-wire
C19 to bare wire
(Pig Tail)
010-9369-03010-9369-03
C20 to C13, 3 feet
010-9369-06
C20 to C13, 6 feet
Outlet Caps
035-0113035-0113:
C13 outlet cap
035-0119035-0119:
C19 outlet cap
    Back To Top

 

Temperature & Humidity Sensors

Optional Sensors
SENSOR - T1-10
(1) Temperature Sensor, 10' Cable
SENSOR - T1H1-10
(1) Temperature and Humidity
Sensor, 10' Cable
SENSOR - T2-10
(2) Temperature Sensor,
10' Cable each
SENSOR - T2H1-10
(1) Temperature and Humidity
Sensor, 10' Cable
(1) Temperature Sensor, 10' Cable
    Back To Top

 

Space-saving mounting options

Installing your new ePDU is quick and easy. There are models that mount horizontally in minimal rack space (1U or 2U), or vertically
in rack side pockets or rear channels—or on a wall or floor, saving traditional U space for IT equipment.
The units come with all mounting hardware included, ready to install. There's no need to purchase additional mounting hardware
or accessories. Some units use a button-mount system and can be mounted in keyhole-type openings in popular racks, with no
tools required.

 

Horizontal Mounting

 

 

 

 

 

 

 

 

 

 

Vertical Mounting

 

 

 

 

 

 

 

 

 

 

 

Benefits of vertical mounts

Eaton ePDUs can be mounted vertically, allowing you to save valuable space. You can mount them vertically in rack side pockets, rear channels – or on a wall, which allows you to save traditional U space for IT equipment.