Power Distribution Unit

The Powerware PDU provides reliable data center power distribution for both raised and non-raised floor applications. To deliver effective power management and monitoring, the Powerware PDU incorporates the Powerware Energy Management System, optimizing both utilization and availability down to the branch circuit level. The optional Power Xpert® Gateway Series 1000 Card provides Web-enabled, real-time monitoring for power quality status and fast response to power-related events.

To ensure the high performance required for today’s data centers, this Eaton®-designed and manufactured PDU delivers maximum flexibility in an integrated, factory-tested package:

Features and Benefits

  • Integrated isolation, monitoring, distribution and a wide array of options
  • Scalable architecture and space-saving design
  • Comprehensive monitoring and connectivity options
  • Unparalleled ease of use through front-access only design, top and bottom cable access, and spacious wire-ways
Electrical Characteristics

Input ratings:

Voltage: 208V, 480V or 600V:
Three-phase, three-wire plus ground (Transformerless: three-phase, four-wire plus ground)
Frequency: 60 Hz
Output ratings:
Voltage: 208V/120V, 480V or 600V: Three-phase, four-wire plus ground
Frequency: 60 Hz
Distribution
Cutler-Hammer® 42 pole panelboards with 225A main breaker
Cutler-Hammer® Series C molded case subfeed breakers up to 225A
Up to eight subfeed breakers
Custom subfeed ratings available
Factory installed branch circuit breakers
Options
Dual main input breakers
High kAIC input breakers
TVSS (80 kA-200 kA)
Lightning arrestor
Transient suppression plate
Floor Stands (12”, 18”, 24” & 36”)
Junction box
Manual restart
Isolated ground
Powerware Energy Management System
Branch circuit monitoring
Remote power panels
Distribution cables (WHIPS)
Communication X-Slots™ (Two)
Physical Characteristics
30 to 50 kVA (K1-K20): 36"W x 32"D x 76"H
200 to 225 kVA (K1-K13): 36”W x 32”D x 76”H
200 to 225 kVA (K20): 41”W x 35”D x 76”H
300 kVA (K1-K20): 41”W x 35”D x 76”H
Monitoring Features

Metered Values:

Input voltage: L-L
Output voltage: L-L & L-N
Phase output current
Neutral current
Ground current
kVA, KW, Hz
Total Harmonic Distortion (THD)
Power factor / phase
Percent load / phase
Load Profiling
Min & Max V, I, Hz, KW recorded over a four hour period
Captures highest reading on monthly basis, with trend information over last 23 months
Alarms
Transformer over-temp. & shutdown
Over-and under-voltage (input & output)
High current (Three-phases, N, G)
Phase rotation (input & output)
Phase loss
Building alarms (Two - programmable)
Voltage THD
Current THD
Over/Under frequency
Output overload (3-Levels)
Modem call
Control
EPO (Optional)
Custom shutdowns on alarms:
  • Phase rotation

  • Phase loss

  • Ground fault

  • Site wiring fault

  • Building alarms

Connectivity
Modbus
Modem
Optional Power Xpert(R) PDU card for network interface

 

 