Powerware Plus 18

Technical Specifications


12-18 kVA
  • Model 12 - 12kVA/8kW

  • Model 15 - 15 kVA/10kW

  • Model 18 - 18kVA/12kW

Input

Voltage Range

See table below

Frequency Range

45-65 Hz

Surge Protection

Meets IEEE 587/ANSI C62.41, Category A & B

Power Factor 0.95 Typical at full load

Output

Voltage Regulation

Better than +/- 3%

Voltage THD

Less than 5% (100% nonlinear load); Less than 3% (100% linear load)

Transient Response

Less than 5% for 100% load, step full recovery within 1/4 cycle

Frequency Regulation (Free Run) +/- 0.1 Hz
Frequency Sync Range +/- 1.0 Hz
Frequency Slew Rate 1 Hz/sec.
Load Crest Ratio 3:1
Common Mode Noise Rejection >100 dB

Battery

Battery Type

Sealed, maintenance-free lead acid

Battery Voltage

240 VDC

Recharge time

12x discharge to 90% capacity

Safety UL 1778 Listed
CUL CAN/CSA C22.2NO.107.1-M91 Listed
EN 50091-1
All Cabinets provide seismic mounting features

Environmental and safety

Audible Noise

<60 dBA at 1 meter

Ambient Operating Temperature

0C to 40C

Ambient Storage Temperature

-20C to +70C

Altitude 5000 ft. (1500 m) without derating

Relative Humidity

5-95% minimum non-condensing

EMI Suppression Meet FCC Class A, Subpart J of Part 15
Electrostatic Discharge Withstands 25kV without damage or disturbance to load

* subject to change without notice.

Model Selection Guide

Nominal Voltage*
(Line-Line)

 Input Voltage

Model 12kVA/8kW

 Model 15kVA/10kW

 Model 18kVA/12kW

 Max.

 Maximum Rated
Current Per Phase

 Max.

 Maximum Rated
Current Per Phase

  Max.

 Maximum Rated
Current Per Phase

 Input

 Output

 Range

 kVA

 Input

 Output

 kVA

 Input

Output

 kVA  Input  Output

 200

200

176-253

 11.7

 29A

 34A

  14.5  36A  42A  17.2  43A  50A

 208

208

176-253

12.2

28A

34A

 15  35A  42A  18  42A  50A

 220

220

176-253

11.8

26A

31A

 14.8  33A  39A  17.9  39A  47A
 

  Model 12kVA/8kW HV

   Model 15kVA/10kW HV

  Model 15kVA/10kW HV

 380

380

367-391

12

15A

18A

 15  19A  23A

 18

 23A  27A

 400

400

388-412

11.9

14A

17A

 15  18A  22A

 17.9

 22A  26A

 415

415

403-427

12

14A

17A

 15.6  18A  22A

 18

 21A  25A

 480

480

467-494

11.6

12A

14A

 15  15A  18A

 18.3

 18A  22A

 480

208

467-494

11.9

12A

33A

 15.1  15A  42A

 18

 18A  50A
* Nominal UPS module input/voltage, i.e If unit is being used as a voltage or frequency converter, the bypass must be disabled. Input/Output voltage, phase and frequency must be equal for bypass operation. Line to neutral voltage=line to line divided by 1.73


Battery Run Times
(in minutes)

Output Watts Standard Battery Configuration 2 EBC2 Cabs 1 EBC1 Cab** + 2 EBC2 Cabs*** 3 EBC2 Cabs***
1000 146 198 250 301
2000 76 105 133 161
3000 50 70 89 109
4000 37 52 68 83
5000 28 40 52 65
6000 22 33 43 53
7000 18 27 36 44
8000 15 22 30 38
9000 12 19 26 33
10,000 10 16 22 29
11,000 8 14 20 25
12,000 7 12 17 22


*Estimated accuracy of battery support times is +/-10%.
**EBC1 is one half-full battery cabinet.
***EBC2 is one full battery cabinet.

 