Rackmount Power Distribution Unit
With data center devices smaller than ever—often served by dual or triple power supplies—a single rack of equipment might produce 40 or more power cords to manage.
And although devices are shrinking, their power consumption is not. Yesterday’s full rack of equipment averaged 5-8 kW of power. Blade servers will soon boost that power consumption up to 20 kW per rack. Traditional power strips just don’t deliver enough power or flexibility.
Superior power quality depends on efficient power distribution.
Eaton provides a complete suite of rackmount products to help IT managers meet these power requirements. Our rackmount UPSs provide reliable, consistent power for a wide range of applications. Our new Powerware Rackmount Power Distribution Units (PDUs) complement your UPS systems, distributing power in high-density rack environments— or anywhere conditioned power must be distributed to multiple pieces of equipment.
From a single power input, you can manage and distribute power to up to 12 output receptacles (NEMA or IEC type). Whether you’re using a UPS from Powerware or another manufacturer, a Powerware PDU delivers the power throughout the rack simply and efficiently.
Features and Benefits
-
Effectively distributes UPS power throughout a rack environment, while organizing power cords
-
Supports a wide range of applications with a variety of NEMA, IEC and hardwired inputs in combination with NEMA and IEC output receptacles
- Provides reliable protection as it is designed to meet UL 60950-1; UL 489-listed circuit breakers provide branch circuit protection as standard
-
Enhances power availability by using separate circuit breakers for groups of receptacles (most models), thereby limiting the impact of overload conditions and maximizing the power output
- Complement to popular UPS solutions. With up to 12 output receptacles to distribute power within the rack environment, the Powerware PDU is compatible with most rackmount UPSs from Eaton and other manufacturers.
- Use rack space efficiently. These PDUs can mount vertically in rack side pockets—or on a wall or floor—saving traditional 1U space for IT equipment. Since all input and output connections are on the same side, two PDUs can be mounted back to back in a single shelf—up to 24 output receptacles in 1U of rack space.
- Wide choice of models. The Powerware PDU family includes models with a variety of power inputs and outputs to fit most power requirements. You can select from NEMA, IEC and hardwired inputs and NEMA- and IEC-type output receptacles (4 to 12 receptacles per PDU in various combinations).
- Separate circuit breakers for outlet groups. Powerware PDUs offer individual circuit breakers to protect outlet groups, or “load segments.” This approach increases overall availability by ensuring that an overloaded circuit does not affect other load segments. Circuit breakers have flat rockers to prevent accidental on/off operation.
- Quick and easily installation. With pre-installed mounting brackets, the unit is immediately ready to install in the rack. There’s no need to purchase additional mounting hardware or accessories. Optional recessed mounting is available to accommodate large input connectors. With standard 12-foot line cords, you have more choices in mounting locations than with the typical 8- or 10-foot cords.
- Design for rugged, reliable performance. Powerware PDUs meet applicable industry standards for IT equipment safety: UL 60950, Safety of Information Technology Equipment including Electrical Business Equipment, 3rd Edition; CSA/cUL 60950; and EN 60950. An optional cable retention bracket prevents power cords from being accidentally disconnected. With visual indication of available incoming power and tripped circuits, you never have to guess the unit’s operational state.
- Standard two-year warranty. Powerware PDUs are covered by a two-year limited factory warranty from Eaton, the company Frost & Sullivan has named “Power Quality Company of the Year” for two years in a row (May 2005).
Specification Details
Model |
PDU1210N |
PDU1212C |
PDU1607N |
PDU1610C |
PDU1610N |
PDU1612C |
| Part Number |
103004538-6501 |
103004548-6501 |
103004549-6501 |
103004550-6501 |
103004545-6501 |
103004547-6501 |
| Number of Receptacles |
10 |
12 |
7 |
10 |
10 |
12 |
| Voltage Range1 |
100–120 V |
100–240 V |
200–240 V |
100–240 V |
100–120 V |
200–240 V |
| Input Connection |
5-15P |
IEC 320-C14 |
L6-20P |
IEC 320-C20 |
L5-20P |
L6-20P |
| Output Circuit Breaker |
15A |
15A |
20A |
20A |
20A |
20A |
| Max Inpt Current Per Phase |
12A |
12A |
16A |
16A |
16A |
16A |
| Max Output Current |
12A |
12A |
16A |
16A |
16A |
16A |
| Receptacles Load Segment #1 |
(10)5-15R |
(12)IEC 320-C13 |
(3)L6-20R
(4)6-20R |
(2)IEC 320-C19
(8)IEC 320-C13 |
(10)5-20R> |
(12)IEC 320-C13 |
| Receptacles Load Segment #2 |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
| Receptacles Load Segment #3 |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
| Safety Markings |
cULus |
CE, cULus, UL/GS |
cULus |
CE, cULus, UL/GS |
cULus |
cULus |
| Mechanical Weight |
4.8 lb/2.2 kg |
5.3 lb/2.4 kg |
7.7 lb/3.5 kg |
5.8 lb/2.6 kg |
5.4 lb/2.4 kg |
5.6 lb/2.5 kg |
| Mechanical Dimensions (WxDxH) |
44.5 x 4.5 x 10.0 cm
17.5" x 1.8" x 4.0" |
44.5 x 4.5 x 10.0 cm
17.5" x 1.8" x 4.0" |
44.5 x 8.9 x 10.0 cm
17.5" x 3.5" x 4.0" |
44.5 x 4.5 x 10.0 cm
17.5" x 1.8" x 4.0" |
44.5 x 4.5 x 10.0 cm
17.5" x 1.8" x 4.0" |
44.5 x 4.5 x 10.0 cm
17.5" x 1.8" x 4.0" |
| Model |
PDU2404C |
PDU2408C |
PDU2408N |
PDU2408N2 |
PDU2408N3 |
PDU3208C |
| Number of Receptacles |
4 |
8 |
8 |
8 |
8 |
8 |
| Voltage Range1 |
200–240 V |
200–240 V |
100–120 V |
200–240 V |
120–240 V |
120–240 V |
| Input Connection |
L6-30P |
L6-30P |
L5-30P |
L6-30P |
L14-30P |
Hardwired |
| Output Circuit Breaker |
(2) 20A |
(2) 20A |
(2) 20A |
(2) 20A; 30A upstream breaker |
(2) 20A; 30A upstream breaker |
(2) 20A |
| Max Inpt Current Per Phase |
24A |
24A |
24A |
24A |
24A |
32A |
| Max Output Current |
16A per segment; 24A total |
16A per segment; 24A total |
16A per segment; 24A total |
16A for Seg 1 & 2; 24A for Seg3; 24A total |
16A for Seg 1 & 2; 24A for Seg3; 24A total |
16A per segment; 24A total |
| Receptacles Load Segment #1 |
(2)IEC 320-C19 |
(1)IEC 320-C19
(3)IEC 320-C13 |
(4)5-20R |
(1)L6-20R
(2)6-20R |
(4)5-20R |
(1)IEC 320-C19
(3)IEC 320-C13 |
| Receptacles Load Segment #2 |
(2)IEC 320-C19 |
(1)IEC 320-C19
(3)IEC 320-C13 |
(4)5-20R |
(1)L6-20R
(2)6-20R |
(2)L6-30R |
(1)IEC 320-C19
(3)IEC 320-C13 |
| Receptacles Load Segment #3 |
N/A |
N/A |
N/A |
(2)L6-30R |
(2)L6-30R |
N/A |
| Safety Markings |
cULus |
cULus |
cULus |
(2)L6-30R |
cULus |
CE, cULus, UL/GS |
| Mechanical Weight |
7.0 lb/3.2 kg |
4.3 lb/2.0 kg |
6.8 lb/3.1 kg |
9.5 lb/4.3 kg |
9.8 lb/4.4 kg |
4.3 lb/2.0 kg |
| Mechanical Dimensions (WxDxH) |
44.5 x 4.5 x 10.0 cm
17.5" x 1.8" x 4.0" |
44.5 x 4.5 x 10.0 cm
17.5" x 1.8" x 4.0" |
44.5 x 4.5 x 10.0 cm
17.5" x 1.8" x 4.0" |
44.5 x 8.9 x 10.0 cm
17.5" x 3.5" x 4.0" |
44.5 x 8.9 x 10.0 cm
17.5" x 3.5" x 4.0" |
44.5 x 4.5 x 10.0 cm
17.5" x 1.8" x 4.0" |
| Environmental |
| Operating Temperature |
0 °C to 45 °C (32 °F to 113 °F) |
| Non-Operating Temperature> |
-25 °C to 70 °C (-13 °F to 158 °F) |
| Relative Humidity |
5-95% noncondensing |
| Operating Altitude> |
Up to 3,000 meters above sea level |
| Non-operating Altitude> |
Up to 5,000 meters above sea level |
1. Frequency - 50/60 Hz
| Options |
| 103004542-6501 |
Cord Retention Bracket |
| 103004679-6501 |
Deep-Recess Mounting Bracket for use with PDU1607N, PDU2408N2 and PDU2408N3 |
| 103004544-6501 |
0U Universal Mounting Bracket |