| UPS Series: |
5115 |
5125 |
5140 |
9125 |
9170+ | 9170+RM |
Ferrups |
| Topology |
Line Interactive |
Double-Conversion
Online |
Ferroresonant |
Output
VA
Rating |
500/750/1050/1500 |
1000/1440/2400/2880 |
6000 |
700/1000/1250/1500/2000
2500/3000/5000/6000 |
3000/6000/9000
12000/15000/18000 |
850/1150/1400/1800/2100
3100/4300/7000 |
Output Wattage
Rating |
350/520/670/1000 |
900/1340/2250/2700 |
6000
1750/2100 |
490/700/875/1050/1400
1750/2100/3500/4200 |
2500/5000/7500
10000/12500/15000 |
600/800/1000/1250
1500/2200/3000/5000 |
| Rack Height |
1U |
2U |
6U |
2U |
10U-34U |
6U-11U |
| Electrical Input |
Nominal Voltage
(VAC) |
120 and 230 |
208, 230 and 240 |
120 208, 230 and 240 |
208-240 or 200/100
208/120, 22/110, 240/120 |
120, 208, or 240 (60Hz)
220, 230, or 240 (50 Hz)
|
Nominal Voltage
Range
(V) |
120 V: 96 - 144 |
120 V: 77 - 152 V
230 V: 154 - 288 V |
208/230 V: 160 - 288
V |
120 V: 80-144 V
208/230 V: 160 - 288 V |
176 - 276 V
208 - 240 V |
240 V: 192 - 276 V |
Operating
Frequency |
50/60Hz, Auto-sensing |
50 Hz or 60 Hz |
| Electrical Output |
On Utility Voltage
Regulation |
-10%
to +6% of nominal |
±3% of
nominal |
On Battery Voltage
Regulation |
±5%
RMS |
±3%
of nominal |
Voltage Wave
Shape
(on battery) |
True
Sine Wave |
Frequency
Regulation |
---- |
---- |
±3
Hz online; ±0.1 Hz on battery |
| Load Crest Factor |
3
to 1 ratio |
Load Segments
(Receptacle
Groups) |
2 |
2-3 |
5 |
3 |
---- |
---- |
| Battery |
Internal Battery
Type |
Maintenance-free,
sealed, valve-regulated lead-aciod (VRLA) |
| Recharge Time |
<3
hours to 90% usable capacity |
Battery
Dependant |
| Transfer Time |
2-4ms |
0ms |
N/A |
0ms |
| Communications |
Network Transient
Protector |
Yes |
No |
Yes |
No |
| REPO Port |
No |
Yes
|
| X-Slot Interface |
Yes |
Non
X-Slot Adapter |
Yes
(2) |
Non
X-Slot adapter |
Standard
Communications |
1
x RS-232 Serial Port
& 1 x USB port |
1
x RS-232 Serial Port |
2
x RS-232 Serial Port |
700-3000
VA: 1xRS-232
5000/6000 VA: RS232 & USB
|
1
x RS-232 Serial Port |
| General |
Dimensions
(HxWxD)
Inches |
500-1500
VA
1.75x17.3x22.8 |
1000-1440
VA:
3.5x19.0x19.4
2400-3000 VA:
3.5x19.0x24.5 |
6000
VA
10.5x17.25x24.3
|
700-2000
VA:
3.5x19.0x19.4
2500-3000 VA:
3.5x19.0x23.9
5000/6000 VA:
8.63x17.37x24.94 |
3-Slot:
17.8x17.0x25.4
6-Slot: 31.5x17.0x25.4
9-Slot:
45.0x17.0x25.4
12-Slot: 58.0x17.0x25.4
|
850-1400
VA:
9.75x16.0x21.25
1800-3100 VA:
9.75x16.0x26.25
4300-7000 VA:
19.0x16.0x26.25
|
| Weight (lb) |
35.2/41.4/41.4/48.6 |
61.0/61.0/89.0/89.0 |
250 |
34.0/34.0/50.0/50.0/50.0/
81.5/81.5/206/206 |
66/103/158/196/
158/196
|
105/135/150/209/
220/238/495/580
|
| Availible colors |
Gray |
Gray
of Black |
Gray |
Gray
or Black |
Gray
or Black |
Gray |
| Rail Kit |
Included |
Optional |
Included |
Optional |
Optional |
Included |
| Environmental |
| Safety Markings |
UL,
cUL, C-Tick
CE, TUV |
UL,
cUL, NOM,
C-Tick, CE
|
UL,
CSA, NOM,
CE, VDE
|
UL,
CSA, NOM, VDE
CE, S, D, N, FI, B, NOM, R |
UL,
cUL, TUV, CE,
C-Tick, BCIQ |
|
| EMC Compliance |
FCC
Part 15
subpart J Class A
ICES-003; EN 50091-2
|
FCC
Part 15
EN50091-2,
Class A + B |
|
FCC
Class B and VCCI Class II,
3000 FCC Class A
|
FCC
Class A |
FCC
Part 15:
Class A & B
|
Internal Fans
for Cooling |
Yes |
Operating
Temperature |
0
to 40ºC (32 to 104ºF) |
| Relative Humidity |
0%
to 95% non-condensing |
| Surge
Suppression |
ANSI
C62.41 Category A (formerly IEEE 587) |
| Audible Noise |
Less
than 40 dBA typical |
|
| Altitude |
Up
to 3000M (10,000 ft) without derating
|
| 1. Specifications
typical and subject to change without notice. |