Remote Power Panel
Powerware RPPs deliver unmatched power distribution with up to 168 factory-installed branch breakers in a highly compact footprint. These products offer ease of installation through standard top and bottom cable entry provisions within a free standing structure. They include extensive monitoring options such as branch circuit monitoring to ensure effective monitoring and power management. The optional Power Xpert® Gateway Series 1000 Card provides Web-enabled, real-time monitoring for power quality status and fast response to power-related events.
Features and Benefits
- Unmatched power distribution with a highly compact footprint
- Ease of installation through standard top and bottom cable entry provision
- Extensive monitoring options allow you to manage power effectively
- Factory-tested power distribution to ensure highest reliability
- Flexible expansion for your power distribution within a data center
| Electrical Characteristics |
| Input ratings: |
100A, 225A, 400A or 800A |
| Phase: |
3Ф, 4 wire + G |
| Frequency: |
60 Hz |
| Input Connection Options |
| Direct connection to panel board main breaker |
| Connection into main lug (up to 800A) |
| Connection into main breakers (100A, 225A, 400A) |
| Distribution |
| Up to 4 Cutler-Hammer 42 pole panel boards with 225A main breakers (2 front, 2 rear) |
| Factory-installed branch circuit breakers |
| Options |
| Multiple incoming options |
| High kAIC input breakers |
| TVSS (100 kA-200 kA) |
| Junction box |
| Isolated ground |
| Powerware Energy Management System |
| Branch circuit monitoring |
| Distribution cables (WHIPS) |
| Isolation barrier for Dual Source Inputs |
| Optional Plexiglass viewing window |
| Physical Characteristics |
| Size: 24”W x 24”D x 78”H |
| Powerware Energy Management System |
| Metered Values: |
| Voltage: L-L |
| Phase current |
| Neutral current |
| Ground current |
| kVA, KW, Hz |
| Total Harmonic Distortion (THD) |
| Power factor / phase |
| Percent load / phase |
| Load Profiling |
| Min & Max V, I, Hz, KW recorded over a four hour period |
| Captures highest reading on monthly basis, with trend information over last 23 months |
| Alarms |
| Over-and under-voltage (input & output) |
| High current (Three-phases, N, G) |
| Phase rotation (input & output) |
| Phase loss |
| Building alarms (Two-programmable) |
| Voltage THD |
| Current THD |
| Over/Under frequency |
| Output overload (3-Levels) |
| Modem call |
| Connectivity |
| Modem |
| Optional Power Xpert® Gateway card for network interface |