Pulizzi IPC34XX Series
Single Phase North American and International use
120 V, 240 V, 15amp, 20amp, 30amp Input
Individual outlet control via Computer, Modem, or LAN
Features |
Benefits |
| Local On/Off control of each outlet through Ethernet, Serial,
Modem, or local buttons on the unit. |
Individual control of outlets lets you operate your equipment with
out affecting other equipment attached to the same PDU. |
| Connect up to 10 IPC units together for the ability to control up to
80 outlets with a single serial or Ethernet connection. |
Save time, money and recourses by using only 1 line or IP
address to manage up to 80 outlets. The RJ485 serial connection
between units allows distances of up to 1000 feet! |
| Voltage range of 100-240VAC via a C20 inlet and C13 outlets.
(IPC3401 and IPC3401-NET) |
This will allow you to use simple universal designs for equipment
that can be used in any country! |
| Connect via Telnet, Web browser interface, Serial, or Modem (with
external modem connect to serial port.) |
Many interfaces allow you to use this unit in many ways as well as
providing back up methods incase of other equipment failure. |
| IPC units designed with EMI/RFI Filtering, TVSS (spike/ surge
suppression), and UL listed circuit breakers |
Units are designed with the latest safety requirements, provide
clean power, and of the highest quality to make certain your
equipment stays up and running saving you time and money. |

Specifications
CHASSIS- 1.75” (1U) x Depth 9.5” x Width
19.0”
- Weighs approximately 19lbs
- 16 GA. Steel, Painted Black,
RACK MOUNTED- EIA standard for 19” racks
- Hole spacing to IEC 297
- Adjustable mounting to front or
rear panel
- Optional vertical or under counter
mounting brackets 001-1928-1 (2
required)
NEMA or IEC 320 OUTLETS- IPC 3401 has 8 IEC60320 Type
C13 (computer style) outlets
- IPC 3402 and IPC3402-2930
have 8 NEMA 5-15R outlets
- IPC 3402-A2 has 8 NEMA 5-20R
outlets
- IPC3402-2756 has 4 NEMA 5-
15R and 4 NEMA 5-20R
11 INDICATOR LIGHTS- Power available to system-CB
“on”
- Power “on” to outlets 1-8
- Data acquisition
- Remote Disable
REMOTE or LOCAL CONTROL- Serial RS232 port (DB9 Male) for
direct or modem connection
- RS485 input/output ports for
strapping up to 10 systems
together over a CAT.5 cable
- Local: one on/off switch for each
outlet
- Ethernet connection to your local
area network (-NET models only).
BAUD RATE |
AVS (AUTO-VOLTAGE
SELECTABLE)- The IPC3401-NET is auto-voltage
sensing for operation 100-250
VAC input/output
EMI/RFI FILTERING- Common Mode - Line to Ground
- Differential Mode - Line to Line
- Filtered inlet isolates noise before
entering the system
SPIKE/SURGE SUPPRESSION- Line to Neutral (Line to Line when
used at 200-240VAC)
LISTED OVERLOAD CIRCUIT
BREAKER PROTECTION- Listed Main Disconnect Breaker,
with a long time delay curve,
which provides both manual
on/off switching and open (trip)
automatically with an overload
condition
- Circuit Breaker (Kick) Guard’s are
provided
POWER INPUT- IEC60320 Type C20 EMI/RFI
Filtered Inlet with optional
retaining clip or cable tray.
- Optional power cable assemblies
are available – see below
OUTLET STATUS- Query the IPC for Outlet and
Watch Dog status, i.e. outlets are
“on” or “off”
STRAPPING- Strapping allows up to 10 IPC’s
(80 outlets) to be controlled at
one address.
- Units are connected together via
the RS485 serial buss for
distances up to 1000’.
|
REMOTE DISABLE- With the push of a button, disable
remote access to the IPC when
needed
PATENTED MULTIPLE TIME
DELAY (MTD)
- Sequence power up and power
down to outlets with a four
second time delay (factory set)
- User Programmable:
- Set power “on” sequence to
any combination of outlets
- Set the MTD timing from 1
second to 999 seconds, i.e.
009 = 9 seconds
ADDRESSING- The IPC comes with a default
address but you can also create
your own with any four
alphanumeric characters
- Strapping allows for connection of
up to 10 units at one address
AUTO-EVENT COMMAND
RESPONSE- The IPC will automatically update
the status of it’s outlets (“on” or
“off”)
SOFTWARE CONTROL- Multi-platform support
- Control via Terminal Emulation
Software such as PCAnywhere,
Hyper Terminal, VT100, and
many others.
- Simple command structures
allows for easy programming of
scripts or batch programs.
- Easy to use Web Browser
interface.
OUTLET NAMING- Give each outlet its own individual
8 character name.
|
Specifications
| Model Number: |
IPC3401 |
IPC3401-NET |
IPC3402 |
IPC3402-NET |
IPC3402-A2 |
IPC3402-A2-NET |
IPC3402-2756 |
IPC3402-2930 |
| Voltage 50/60Hz |
120V~ or 240V~ |
120V~ or 240V~ |
120V~ |
120V~ |
120V~ |
120V~ |
120V~ |
120V~ |
| Current Input |
20A @ 120V~
16A @ 240V~ |
20A @ 120V~
16A @ 240V~ |
20A |
20A |
20A |
20A |
30A |
30A |
| Current Output |
16A |
16A |
16A |
16A |
16A |
16A |
24A |
24A |
| Full Load V/A |
1920VA @ 120V
3840VA @ 240V |
1920VA @ 120V
3840VA @ 240V |
1920VA |
1920VA |
1920VA |
1920VA |
2880VA |
2880VA |
| Ethernet Card |
NO |
YES |
NO |
YES |
NO |
YES |
YES |
YES |
| Outlets |
IEC C13 |
IEC C13 |
NEMA 5-15R |
NEMA 5-15R |
NEMA 5-20R |
NEMA 5-20R |
(4) 5-20R &
(4) 5-15R |
NEMA 5-15R |
| Circuit Breaker |
20/20A |
20/20A |
20A |
20A |
20A |
20A |
20A/10A |
15A/15A |
| EMI/RFI Filter |
20A |
20A |
20A |
20A |
20A |
20A |
NO |
NO |
| TVSS |
YES |
YES |
YES |
YES |
YES |
YES |
YES |
YES |
| Power cable / Inlet |
C20 Inlet |
C20 Inlet |
C20 Inlet |
C20 Inlet |
C20 Inlet |
C20 Inlet |
10' Cable |
10' Cable |
| Cable/plug |
Not Included |
Not Included |
Not Included |
Not Included |
Not Included |
Not Included |
L5-30P |
L5-30P |
Part Number |
IEC Jumper Cable (from IPC3401 to “computer” style inlet) |
| 010-0025 |
C13 to C14: 8’ LENGTH JUMPER CABLE |
| 010-0027 |
C13 to C14: 6’ LENGTH JUMPER CABLE |
| 010-0028 |
C13 to C14: 4’ LENGTH JUMPER CABLE |
| 010-0029 |
C13 to C14: 2’ LENGTH JUMPER CABLE |
Part Number |
Power Cable Description (C19 end connects to IPC34xx) |
| 010-9334 |
C19, 8', 14/3 SJT, NEMA 5-15P (125V, 15A) STRAIGHT |
| 010-9335 |
C19, 8', 12/3 SJT, NEMA 5-20P (125V, 20A) STRAIGHT |
| 010-9336 |
C19, 8', 14/3 SJT, NEMA 6-15P (250V, 15A) STRAIGHT |
| 010-9337 |
C19, 8', 12/3 SJT, NEMA 6-20P (250V, 20A) STRAIGHT |
| 010-9338 |
C19, 8', 14/3 SJT, NEMA L5-15P (125V, 15A) TWISTLOCK |
| 010-9339 |
C19, 8', 12/3 SJT, NEMA L5-20P (125V, 20A) TWISTLOCK |
| 010-9340 |
C19, 8', 14/3 SJT, NEMA L6-15P (250V, 15A) TWISTLOCK |
| 010-9341 |
C19, 8', 12/3 SJT, NEMA L6-20P (250V, 20A) TWISTLOCK |
| 010-9342 |
C19, 8', 12/3 SJT, C20 MALE (20 AMP) |
| 010-9343 |
C19, 2.5m, 1.5mm/3 HAR, CEE7-7 (250V, 16A) EUROPEAN |
| 010-9344 |
C19, 2.5m, 1.5mm/3 HAR, BS546A (250V, 15A) BRITISH |
| 010-9345 |
C19, 2.5m, 1.5mm/3 HAR, AS/NZS 3112 (250V, 15A) AUSTRALIAN |
| 010-9346 |
C19, 2.5m, 1.5mm/3 HAR, SI32 (250V, 16A) ISRAELI |
| 010-9347 | C19, 2.5m, 1.5mm/3 HAR, CEI23-16 (250V, 16A) ITALIAN |
COMMAND STRUCTURE: UPPER CASE ONLY, FOLLOWED BY “Enter”, “Carriage Return” or “Line Feed”.
NOTE: The lower case “xx” or “n” in command code represents: xx=outlet number 01-80 and n= the unit number 0-9.
8 BIT ASCII |
DESCRIPTION |
| A1n |
Turn all outlets ON |
| A0n |
Turn all outlets OFF |
| Nxx |
Turn ON any outlet |
| Fxx |
Turn OFF any outlet |
| S1n |
Sequence all outlets in unit “n” ON with
preset delays (factory set at 4s) |
| S0n |
Sequence all outlets in unit “n” OFF with
preset delays (factory set at 4s) |
| ADn |
Enter new IPC user name (4 characters) |
| ISn |
Set Power up/down sequence. IPC will
ask for (P) Preset or (D) Default? (D) =
Previous setting and (P) = Enter new |
| DXn |
Display outlet status ON or OFF,
Watchdog and Remote Status |
| AEn |
Auto status update enabled YES / NO |
| WE0 |
Watchdog enabled for unit “0” only |
| WT0 |
Watchdog timeout set for unit “0” only |
| WD0 |
Watchdog disabled for unit “0” only |
| PWn |
Enter user password (3 characters) |
| PDn |
Password disabled |
| SR0 |
Outlet 1 in unit 0 will automatically reboot
in 5s |
| LO |
Logout |
| CNnx |
Set outlet x name on unit n up to eight
charters. |
| DNn |
Display outlet status with names,
Watchdog and Remote Status |
| ? |
Display Command menu |
MOV Specifications |
|
Continuous AC Voltage
|
270VAC |
Continuous DC Voltage
|
360VDC |
Maximum DC Leakage
|
200μA |
Low Varistor Voltage Limit
|
389VDC |
High Varistor Voltage Limit
|
453VDC |
Nominal Varistor Voltage
|
424VDC |
Current For Varistor Voltage
|
1mA |
Maximum Clamp Voltage 8x20μs
|
680V |
Maximum Clamp Voltage Test Current
|
100A |
Peak Current Rating (1 Pulse) 8x20μs
|
10000A |
Peak Current Rating (2 Pulse) 8x20μs
|
6500A |
Energy Rating (10x100μs)
|
325J |
Energy Rating (8x20μs)
|
325.00J |
Capacitance 970
|
pF |
| Impulse Response Time |
50ns |
EMI/RFI FILTERING
Rated Voltage/Current:
- 125V/20A UL and CSA
- 250V/16A UL, CSA and VDE
Operating Frequency:
Hi-pot rating 1 minute:
- 2250 VDC Line-Ground
- 1450 VDC Line-Line
Maximum Leakage Current (each line-ground):
UL #E72928, CSA #LR97784, VDE #1104884
COMMON MODE INSERTION LOSS
(Line to Ground in 50ohm circuit)
| Mhz. |
.01 |
1 |
10 |
20 |
50 |
100 |
| dB. |
8 |
29 |
40 |
50 |
68 |
40 |
COMMON MODE INSERTION LOSS
(Line to Ground in 50ohm circuit)
| Mhz. |
.01 |
1 |
10 |
20 |
50 |
100 |
| dB. |
8 |
23 |
45 |
58 |
32 |
28 |
|