Bomara Associates Logo
S.I. Tech - Presented by Bomara Associates

 

Bomara Associates Homepage

Model 2817

TTL to Fiber Optic Transmitter/Receiver

S.I. Tech Model 2817 TTL to Fiber Optic Transmitter/Receiver

S.I. Tech Model 2817

TRANSMISSION LINE INTERFACE
Operating distance is dependent upon optical fiber core diameter and the cable's optical attenuation. The table below indicates three cables that may be used at any data rate. These cables are available in connectorized assemblies to meet the exact configuration of your application.

S.I.Tech offers complete links including fiber optic cable, connectors, cable assemblies, and Bit-DriversŪ.

Operating Distance for Fiber Optic Cable

S.I. Tech Model 2817 Diagram

Optical unit connection: Connect the optical transmission line to the T and R receptacles. Note which cable channel goes to T or R by noting cable imprint. On the other end, reverse the connection.

System

Transmission:Up to 6500 ft. (2 Km) with suitable graded index fiber optic cable or 10 Km using single mode fiber
Typical Bit Error Rate:Better than 10-9

Electrical Signal Input/Output
for Transmitter and Receiver

Format:TTL
Connector:BNC
Data Rate:Up to 20Mbps
Input impedance:TTL levels 10 KΩ
Output Impedance:TTL levels into 50 KΩ
Input Power:8 to 15VDC 250mA Max.

Optical Transmitter

LED Current:30 microwatts (-15 dBm) into 62.5 micron fiber
Wavelength:820 nanometers (1300 nm option)
Emitter Type:LED
Optical Connector:ST

Optical Receiver

Wavelength:820 nm (1300 nm option)
Minimum Sensitivity: (BER 10-9) 3 microwatt (-25 dBm) @ 820 nanometers
Maximum Sensitivity:10 microwatts
Optical Connector:ST
Operating Temperature:0°C to 50°C
Size:5.125" X 2.125" X 1.0"
(13.00 X 5.40 X 2.54 cm)

S.I. Tech Model 2817 Diagram



S.I. Tech Home
Bomara Homepage
Request Information

Bomara Associates Phone: 800.5BOMARA (800.526.6272) Phone: 978.452.2299 Fax: 978.452.1169 3 Courthouse Lane, Chelmsford, MA 01824 USA
email: bobr@bomara.com   web: www.bomara.com