Unipower »Rectifiers & Shelves» BlueStreak Series

BLUEstreak Series

BlueStreak Hot Swappable Rectifier
BLUEstreak is Unipower Corporation’s new generation high density hotswappable, modular Front-Ends and Rectifiers producing up to 2000 watts output power. There are 6 standard models with different output voltages and power levels. The modules are ultra-compact with power density up to 24 watts per cubic inch. The modules have automatic load sharing and active output ORing circuit so they can be hot-swapped while the system is
operating. Using PMBus compliant serial communications, status and control data can be passed between a host system or power management unit and the module. Front panel mounted LEDs indicate various status or fault conditions and +5V & 12V standby outputs are included. Operating temperature range is -40°C to +70°C.
FEATURES
  • Up to 92% Efficiency
  • 1U High: 1.6”
  • -40°C to +70°C Operation
  • Wide Range AC Input
  • Up to 2000W Output
  • >0.98 Power Factor
  • Output Voltages: 12 to 54.4VDC
  • Power Density to 24W/Cu. Inch
  • Hot Swappable
  • Class B EMI Filter
  • LED Indicators
  • PMBus Serial Communications
  • Variable Speed Cooling Fans

Technical Specidications:

Input
Voltage Range  
See Model Table
Power Factor  
>0.98
Total Harmonic Distortion, Max 
5%
Frequency 
47-63Hz
Inrush Current Limiting, Max 
50A Peak
EMI Filter, Conducted 
FCC20780 pt 15J Curve B; EN55022 Curve B
Fast Transients 
EN61000-4-4
Surges 
EN61000-4-5
Remote Adjust 
0 to +5V
Input Protection 
Internal Fuse, 25A
Output
Current & Voltage  
See Table
Output Power 
1200-2000W
Voltage Adjustment Range:
48V / 544V 
30-60V
24V / 272V 
15-30V
12V / 136V 
7.5-15V
Standby Output 
+5V@1.8A; +12V@0.8A
Line & Load Regulation, Max 
0.30%
Holdup Time 
10msec
Overvoltage Protection 
Latch Off
Filtering: Wideband Noise, 20MHz BW 
200mV
Current Limit  
105-115% Rated Current (Programmable)
Effi ciency (54.4VDC @ 2000W rated):
100% Load 
to 91.6%
75% Load 
to 92.0%
40% Load
 
to 91.0%
Safety Standards:
UL60950-1, CSA22.2 No 60950-1, EN60950-1
Status Indicators
Status
Green LED
Fault 
Red LED
Alarm Signals (open drain, TTL compatible)
ACOK  
AC present, 5V standby operating
DCOK 
DC output within -10% of nominal
TEMPOK  
Internal temperature within limits
FANOK 
Fans running correctly
PMBus
Version Compliance  
1.1
Environmental
Operating Temp Range 
-20°C to +70°C
Output Current Derating 
2.5%/°C, 50°C to 70°C
Storage Temp Range 
-40°C to + 85°C
Humidity
0% to 95%, Non-Condensing
ESD  
Bellcore GR-1089-Core and EN61000-4-2
MTBF, 35oC (Bellcore) 
200,000 Hours
Cooling 
Integral Ball Bearing Fans
Physical Specifications
Case Material 
Steel
Dimensions, Inches (mm) 
1.60 H x 4.00 W x 13.70 D; (40.6 x 102 x 347.9)
Weight  
4.0 lbs (1.8 kg)

BlueStreak Diagram

SIGNAL PIN CONNECTIONS

PIN FUNCTION PIN FUNCTION
A1 MODULE PRESENT C1 Sense +Ve 4
A2 GA6 C2 Current Monitor 4
A3 GA3 C3 GA1
A4 Standby Return C4 5V Standby 1, 3
A5 FANOK C5 DCOK
A6 SMBALERT C6 SCL
B1 Sense -Ve D1 Remote Adjust 4
B2 Control D2 Current Share 4
B3 GA2 D3 GA0
B4 Standby Return D4 12V Standby 2, 3
B5 TEMPOK D5 ACOK
B6 SDA D6 ENABLE

LED indicators:

Green LED (Top)
LED Status Condition
ON DCOK is TRUE
FLASHING DCOK is FALSE - unit inhibited
OFF DCOK is FALSE - unit not inhibited
Red LED (Bottom)
LED Status Condition Possible causes
ON DC output OFF Temperature above/below allowed limits. OVP. Overcurrent or Short Circuit (DCOK goes FALSE). Processor Failure. (Green LED OFF).
FLASHING DC output ON
(warning)
Fans below expected speed. Temperature high/low. Output current close to maximum. Output on but DCOK FALSE. AC input voltage outside range.
OFF DC output ON  

PUSH BUTTONS:

The two push buttons located just above the LEDs can be used to adjust the output voltage when the output is enabled. These buttons are labelled V▲ and V▼. Short presses for a fraction of a second adjust the output voltage at the output voltage setting resolution. If the button is held down, the rate of change increases to around 1V/s after 10s. If both buttons are pressed together, the button adjust is cleared to zero. The PMBus can read the button adjust value and also clear the value. The PMBus can also be used to enable or disable the buttons.

PMBus SPECIFICATIONS:

PHYSICAL ADDRESSING

The module responds to a single PMBus address. Multiple units can be used together on a single bus by configuring each module with a different physical address. Five of the address bits are brought out on the module connector and these may be either tied high (to 5VSB) or low (to SBReturn) to configure the address. The other two bits GA5 and GA4 are internally set to low and high respectively. The table below summarizes the addressing capability. This gives the module 32 possible addresses, in two banks of 16.
GA6 GA5 GA4 GA3 GA2 GA1 GA0 R/W
A2 0 1 A3 B3 C3 D3 x


BUS SPEED

Minimum 10kHz
Maximum 100kHz


DC SPECIFICATIONS

Vil, SMBus signal input low 0.8V max.
Vih, SMBus signal input high 2.1V min. / 5.0V max
Vol, SMBus signal output low (@pullup) 0.4V min.
Ipullup Current sinking, Vol=0.4V 4mA min.
Ci, capacitance of SCL or SDA pin 25pF max


FAULT REPORTING

faults are reported using the SMBALERT signal. This allows the bus master to determine if a fault has occurred so that it can quickly determine which module has a fault.


Packet Error Checking (PEC)

The Bluestreak PMBus implementation supports packet error checking. The user may configure messages with an additional CRC check byte at the end. Any errors will cause an alert enabling the master to resend the message. Messages received from the module also have a PEC byte appended to the end. This byte may be read if required or only
the message bytes may be read.

PMBus pin summary

The following table is a summary of all available PMBus pins with a short description of the function of each.
Pin Name Function
C6 SCL SMBus Serial Clock
B6 SDA SMBus Serial Data
D3 GA0 Address Configuration
C3 GA1 Address Configuration
B3 GA2 Address Configuration
A3 GA3 Address Configuration
A2 GA6 Address Configuration
A6 SMB ALERT Alert Interrupt Signal
B2 CONTROL Can be configured to turn the unit ON/OFF

PMBus Comand Summary:

 