KEY FEATURES

  • All Connections Made on the Front
  • One Mounting Position High: 1.75”
  • 19- or 23-Inch Rack Mounting
  • GMT Fuses
  • Single Bus with 4 or 6 Fuses
  • Dual Bus (A/B) with 4 or 6 Fuses per Bus
  • Bus Capacity: 80A per Bus
  • Operating Voltage: 12, 24 or 48VDC
  • Positive or Negative Ground
  • A & B are Isolated Loads
  • A & B Can Be Separately Configured
  • ½A to 12A Fuses
  • Red LED Fuse Alarm
  • Alarm: Two Form C Relay Contacts per Load
  • Rack Offset Every ¼", Front to Back

DESCRIPTION

Unipower Telecom’s DPGF1U Series of all Front Connected GMT fuse distribution panels provide distribution and overload protection for 4/6 or 8/12 circuits. The one mounting position (1.75 inches) high GMT fuse panels provide 4/6 single-bus fuses or 8/12 dual-bus (A&B) fuses (4 or 6 per bus). They distribute up to a total of 160 amperes of load current from two separate 80-ampere sources with true A and B distribution and alarm capabilities.

A and B sections of the dual-bus panel are isolated and can be separately configured for 12, 24 or 48 volts, positive or negative ground. Fuse sizes are ½ to 20 amperes.

Fuse alarm is indicated by a red LED for each bus and two Form C relay contacts per bus.

The panels come with brackets that permit mounting in either a 19- or 23-inch relay rack. They can be mounted from the front of the rack with offsets every quarter-inch from front to back to align with existing rack-mounted equipment.

 

DISTRIBUTION PANELS

MODEL NUMBER BUS FUSES
DPGF1U-A-4
DPGF1U-A-6
DPGF1U-A-4-B-4
DPGF1U-A-6-B-6
Single 80A
SINGLE 80A
DUAL 80A / 80A
DUAL 80A / 80A
4 x 20A
4 x 15A + 2 x 20A
4 x 20A per bus
4 x 15A + 2 x 20A per bus

GMT FUSES

AMPS COLOR ORDER CODE
1/2
Red GMT-0-5
3/4
Brown GMT-0-75
1
Gray GMT-1
1 1/3
White GMT-1-33
2
Orange GMT-2
3
Blue GMT-3
5
Green GMT-5
10
Red-White GMT-10
12
Green-Yellow GMT-12
15
Red-Blue GMT-15
20
Green-White GMT-20
Dummy 
  GMT-Dummy

Order fuses separately. Unipower Telecom recommends Bussman fuses for this panel. They may be ordered from Unipower Telecom or directly from Bussman. Use part number from the table.

Crimp type lugs should be ordered separately. For a kit of 4 two-hole lugs for no. 6 AWG wire, order no. 775-1434-0000, $20.00.

 

TECHNICAL SPECIFICATIONS

INPUT / OUTPUT

  • Panel Capacity: 80A Per Bus, 160A Total
  • Configuration
    • Single Bus with 4 or 6 Fuses
    • Dual Bus with 4 or 6 Fuses Each
  • Fuse Type: GMT
  • Fuse Capacity1: 4 x 15A max. with 2 x 20A max. OR 4 x 20A max
  • Voltage2
    • 48V Version: 42-60 VDC
    • 24V Version : 21-30 VDC
    • 12V Version: 10.5-15 VDC
  • Polarity2: Positive or Negative Ground

ALARMS

  • Alarm Indicator: RED LED Per Bus
  • LED Status Indication
    • Red = Alarm
  • Alarm Connections: 2 Form C Relay Contacts Per Bus

SAFETY STANDARDS: UL60950-1, CSA22.2 No.950-1, EN60-950-1

ENVIRONMENTAL

  • Operating Temp. Range: -10°C to +70°C
  • Storage Temp. Range: -40°C to +85°C
  • Humidity: 0% to 95%, Non-Condensing

PHYSICAL

  • Case Material: Steel
  • Finish: Powder Coat Gray
  • Dimensions: 1.75"H x 19.00"W x 9.00"D (44.5mm x 483mm x 229mm)
  • Weight: 8.38 lbs (3.80 kg)
  • Rack Mounting Width: 19 or 23 inches

CONNECTIONS

  • Input Connections: Crimp Type Lug or ¼-20 Stud
  • Output Connections: Barrier Terminal Strips
  • Chassis Ground Connection: No. 8-32 Stud
  • Fail Alarm Connections: 0.045" sq. Wirewrap Pins

NOTES:

  1. See table above for fuse sizes.
  2. See Ordering Guide to specify voltage and polarity.