PCM500 Series

>> Pictures and Diagrams
<< Back to Unipower Telecom Home

KEY FEATURES

  • One Mounting Position High (1.75")
  • 19- or 23-Inch Rack Mounting
  • Positive or Negative Polarity Plant
  • Reverse Polarity Protected
  • 48 or 24 VDC Versions
  • Controls & Monitors up to 16 Rectifiers
  • Centralized Plant Float Voltage Adjust
  • Centralized Plant Equalize Voltage Adjust Option
  • Battery Temp. Compensation Option
  • Optional Digital Voltmeter and Ammeter Panel
  • 8 LED Alarm Indicators
  • 8 Form C Relay Contact Alarm Outputs
  • Over & Under Battery Voltage Alarms
  • Battery Voltage & Current Test Points
  • Compatible with Mercury & Vanguard Rectifiers
  • Easy Wire Connections on Rear
  • Alarm Enable on Back Panel

DESCRIPTION

Unipower Telecom's PCM500 Series Power Control and Monitor System (PCMS) is a one mounting position high (1.75 inches) basic control and monitoring system for DC power plants. It controls up to 16 rectifiers in up to 4 shelves, precisely setting the float voltage and equalize voltage (optional) on all rectifiers simultaneously. It monitors the battery voltage and current by means of front panel test points or optionally by a front panel digital voltmeter and ammeter.

A front panel yellow LED indicates that the controller is in the optional equalize voltage mode. Front panel red LEDs give the following alarms: Rectifier minor fail alarm, indicating a single rectifier failure; rectifier major fail alarm, indicating two or more rectifier failures; AC input failure on any rectifier; failure on any fuse or circuit breaker; failure on one or both low voltage disconnets; battery overvoltage; and battery undervoltage. These alarms all have isolated Form C relay contact ouputs.

The PCM500 is available in either 48 or 24 VDC versions and will operate with a positive or negative polarity plant. It comes with brackets that permit mounting in either a 19- or 23-inch relay rack and can be mounted from the front of the rack with offsets every quarter-inch from front to back to align with existing rack-mounted equipment. The front panel has voltage adjustment potentiometers for float voltage, equalize voltage (option), battery overvoltage and undervoltage, and temperature compensation set (option). A front panel switch puts the PCMS in either float or equalize voltage mode. A front panel green/red LED indicates the controller is operating or has failed. The PCM500 mates with Unipower Telecom's rectifiers and shelves.

 

TECHNICAL SPECIFICATIONS

INPUTS

  • Voltage1: 48VDC or 24VDC Nominal
  • Polarity: Positive or Negative Plant
  • Monitoring Inputs
    • Low Voltage Disconnects 1 & 2
    • Fuse Alarms 1 through 5
    • Battery Voltage & Current Metering
    • Temperature Compensation
    • Battery Sense
    • Battery Supply

OUTPUTS

  • Control Outputs
    • Current Share
    • Remote Adjust
  • Alarms (Form C Relay Contacts)
    • Equalize Failure
    • Minor Rectifier Failure
    • Major Rectifier Failure
    • AC Failure
    • Fuse or Breaker Failure
    • Low Voltage Disconnect
    • Battery Overvoltage
    • Battery Undervoltage

SAFETY STANDARDS: UL1950, CSA22.2 #950, EN60-950

ENVIRONMENTAL

  • Operating Temp. Range: 0°C to +50°C
  • Storage Temp. Range: -40°C to +85°C
  • Humidity: 0% to 95%, Non-Condensing

PHYSICAL

  • Case Material: Steel
  • Finish: Powder Coat Gray
  • Dimensions: 1.75"H x 19.00"W x 9.00"D (44.5mm x 483mm x 229mm)
  • Rack Mounting Width: 19 or 23 inches

NOTES:

  1. Model must be specified for operating voltage.

 