Servertech Home » -48 VDC Power Management » 4805-XMS-16B

  4805-XMS-16B

Discontinued - Contact Bomara for Assistance
Product Description Product Image

Network Monitoring

  • Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
Temperature/Humidity Monitoring
  • Master and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
Branch Circuit Protection
  • This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through the use of user specified TPC fuses.
Outlet Control
  • On Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.


4805-XMS-16B
Click here to enlarge the image.

  • Tech Specs

Technical Specifications for the 4805-XMS-16B:


Inputs
Input Voltage (V) -48
Input Terminal (2) x 1/4-20 dual-studs on 5/8 in. centers (100A max)
Input Current (A) 200
Input Current Rated (A) 200
Input Power Capacity (kW) 9.6
Outputs
Terminals: (16) x Screw-down terminals (10A max)
Branch Circuit Protection
GMT Fuses Included
Physical
Dimensions: 3.5in tall x 17.0in wide x 12.0in deep [89mm x 432mm x 305mm]
Environmental
Operating Environment 32°F to 122°F / 0°C to 50°C | 8%RH to 90%RH non-condensing | 6,500ft/2km elevation
Storage Environment -40°F to 185°F / -40°C to 85°C | 8%RH to 90%RH non-condensing | 50,000ft/15km elevation
Communications & Security
10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector)
Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) - {also on Link PDU}
Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP
Certifications
North American :
cTUVus Mark to UL 60950-1:2007 R10.14
CAN/CSA-C22.2 No. 60950-1-07+A1:2011+A2:2014
FCC Part 15 Subpart B Sections 15.107 and 15.109, Class A
Measurement Accuracy
Input Measurement Accuracy LED Current = ± 10% at 0.1 amp (0.5 - 9.9 amps) and 1 amp (> 9.9 amps) resolution
Optional Accessories
EMTH-1-1 Combination Temperature/Humidity Probe, 10ft (3m)
EMCU-1-1B Environmental Monitor adding:
- Two (2) EMTH-1-1 temperature/humidity ports (one probe included)
- One (1) EMWS-1-1 water sensor port (probe sold separately)
- Four (4) dry contact (NO/NC) monitoring points
- One (1) 8-bit analog-to-digital converter (0 to 5VDC)

KIT-SUS-01 StartUp Stick™ for rapid configurationMounting Brackets
- mounting brackets included
- See the Mounting Bracket Guide for further suggestions
- Custom mounting options available. Contact your local Server Technology representative
Additional Information
Warranty Server Technology offers a standard 2-year limited parts & labor warranty. Extended support is available at the time of purchase. Contact Bomara for more information.

 




Call Us: 1-978-452-2299