Servertech Home » Switched POPS PDUs » C2WG24SN-2CJN5D6

  C2WG24SN-2CJN5D6

Product Description Product Image

HDOT Cx

  • Cx is the future ready UL tested hybrid of the C13 and C19 outlets accommodating both C20 and C14 plugs.
Network Monitoring
  • Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
Hot-Swap Network Card
  • Network access is ensured when power is lost to the Master unit with backup power provided by the primary link unit.
Star Multi-Linking
  • Provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.
Temperature/Humidity Monitoring
  • Master and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.


C2WG24SN-2CJN5D6

  • Tech Specs

Technical Specifications for the C2WG24SN-2CJN5D6:


Inputs
Input Voltage (V) 208
Input Plug NEMA L6-30P
Input Current (A) 30
Input Current Rated (A) 24
Input Power Capacity (kW) 5.0
Outputs
(18) x IEC 60320/C13 North American Rating: ≤ 12A @208V L-L (15A Peak)
(6) x Cx North American Rating: ≤ 16A @208V L-L (20A Peak)
Branch Circuit Protection
UL489 Compliant 2-pole, 20A trip circuit breakers, three (3) branch, rating: ≤ 16A, 10 kAIC Interrupt Rating
Physical
Dimensions: 3.5in tall x 17.2in wide x 17.5in deep [89mm x 437mm x 445mm]
Environmental
Operating Environment 32°F to 122°F / 0°C to 50°C | 8%RH to 90%RH non-condensing | 6,500ft/2km elevation
Storage Environment -40°F to 185°F / -40°C to 85°C | 8%RH to 90%RH non-condensing | 50,000ft/15km elevation
Communications & Security
10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector)
Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) - {also on Link PDU}
Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP
Certifications
North American :
cTUVus Mark to UL 60950-1:2007 R10.14
CAN/CSA-C22.2 No. 60950-1-07+A1:2011+A2:2014
FCC Part 15 Subpart B Sections 15.107 and 15.109, Class A
Measurement Accuracy
Input Measurement Accuracy LED Current = ± 10% at 0.1 amp (0.3 - 9.9 amps) and 1 amp (> 9.9 amps) resolution
Output Measurement Accuracy GUI Current = ± 1% at 0.01 amp resolution (above 0.15 amp)
Branch Measurement Accuracy Current = ± 3% at 0.01 amp resolution (above 0.5 amp)
Optional Accessories
EMTH-1-1 Combination Temperature/Humidity Probe, 10ft (3m)
EMCU-1-1B Environmental Monitor adding:
- Two (2) EMTH-1-1 temperature/humidity ports (one probe included)
- One (1) EMWS-1-1 water sensor port (probe sold separately)
- Four (4) dry contact (NO/NC) monitoring points
- One (1) 8-bit analog-to-digital converter (0 to 5VDC)
KIT-PRO2LINK-01M or -01D provides ability to link (2) additional PRO2 units
KIT-SUS-01 StartUp Stick™ for rapid configurationMounting Brackets
- mounting brackets included
- See the Mounting Bracket Guide for further suggestions
- Custom mounting options available. Contact your local Server Technology representative
Cable Retention Devices for non-locking cords
- EZip
- Cable Sleeve
Additional Information
Warranty Server Technology offers a standard 2-year limited parts & labor warranty. Extended support is available at the time of purchase. Contact Bomara for more information.

 