Server Technology Products » Smart IP PDU » Smart CS-24H5 415V 20/30A 3Ph 18xC13 & 6xC19 with PIPS

 Server Technology Smart CS-24H5: 415V 20/30A 3 Phase 18xC13 & 6xC19 with PIPS

• All the products featured on this page are discontinued except for the accessories
• 240/415V power high density, mixed outlet, horizontal power distribution


CS-24H_masterCS-24H_outlets



  • Description
  • Specifications
  • Gallery

The 3 Phase Sentry CS-24H5 products provide both C13 and C19 outlets for high density applications found in data center cabinets. Smart Cabinet Distribution Units (CDU) provide reliable 3-phase power distribution combined with local and remote power monitoring and environmental monitoring via IP.

This Sentry PIPS CDU combines all of the features of a Smart CDU with the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy. This information replaces branch circuit monitoring devices typically installed in the power distribution panel or remote power panel (RPP) with higher accuracy and lower cost monitoring of each circuit attached to the CDU.

Combine the Sentry PIPS Smart Cabinet PDU with the Sentry Power Manager (SPM) software tool to gain power usage information across multiple Cabinet PDU's individual IP address.

This Smart cabinet PDU delivers reliable power distribution, local power monitoring via LEDs, power monitoring via IP and environmental (temperature & humidity) monitoring via IP.

The Sentry Cabinet Power Distribution Unit (CDU) is an intelligent PDU with local LED input current monitoring, allowing network engineers to utilize the Cabinet PDUs True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new equipment units are added to the power drop, immediately observe its impact on the cumulative current draw. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit.

The PDU meets new UL 60950-1 Branch Circuit Protection requirements. Each branch circuit utilizes circuit breakers (UL-489 rated circuit breakers) as an Overcurrent Protection Device (OCPD). 

 

Remote Power Monitoring

Monitor input power via IP or serial interface.

HTTP/HTTPs Web Configuration & Control

Use the Sentry Web interface to configure each unit's network settings. SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.

SNMP Management & Event Notification

The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information such as input power, temperature and humidity. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, and closed contacts (cabinet doors open/close).

Add a Second Tower

Connect an Expansion Cabinet PDU to this Smart Cabinet PDU to control two power input circuits and monitor power in the Data Center cabinet (individual or groups) under 1 IP address - our exclusive strategy for managing dual power-supply servers.

Secure Access - SSH or SSL Protection

Secure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device.  Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers.  Sentry supports SSLv3/TLSv1.

Integrated Temp/Humidity Probe Support

Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.

Firmware Flash Upgradable

Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.

LDAP/LDAPS

The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be individually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on individual Sentry products.
Sentry LDAP support has been tested in the following environments:
  - Microsoft Active Directory (MSAD)
  - Novell eDirectory (eDir)
  - Open LDAP

RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.


Sentry  Cabinet PDU Specifications
Item # Available Input
Voltages
Rated Amperage Available Input Cord** Outlets Dimensions
(L x W x D)
CS-24H5 -3Ph 20/30A 18xC13 & 6xC19 with PIPS
CS-24H53484A1
CL-24H53484A1*
240/415V 3-Phase Wye, 50/60Hz 20A IEC Red 6Hr 3P+N+G Plug, 10'(3m) Cord (18) IEC 60320/C13
(6) IEC 60320/C19
5.25 x 17.2 x 10.0 in. (133 x 437 x 254 mm)
CS-24H54484A1
CL-24H54484A1*
240/415V 3-Phase Wye, 50/60Hz 30A IEC Red 6Hr 3P+N+G Plug, 10'(3m) Cord (18) IEC 60320/C13
(6) IEC 60320/C19
5.25 x 17.2 x 10.0 in. (133 x 437 x 254 mm)
CS-24H5Z484A1
CL-24H5Z484A1*
240/415V 3-Phase Wye, 50/60Hz 30A NEMA L22-30P Plug, 10'(3m) Cord (18) IEC 60320/C13
(6) IEC 60320/C19
5.25 x 17.2 x 10.0 in. (133 x 437 x 254 mm)
*CL refers to the Expansion Module
**Click here to view additional information on Power Cords and Cables


  Additional Ordering Information


Part Number Input Output
Master Expansion Rating, North America GS Input Type Output Rating North America GS Outlet: North America GS Outlet Type Branch Circuit: North America / GS Phase: North America / GS
CS-24H4J484A1 CL-24H4J484A1   230/400V 3W+N+PE, 50/60Hz; 16A IEC 60309 16A   230V, 50/60Hz; <= 48A   6xC19 <=16A each, 18xC13 <=10A each IEC 60320 C13 & C19 /L1a, L1b, L2a, L2b, L3a, L3b <= 16A /L1, L2, L3 <=16A
CS-24H4K484A1 CL-24H4K484A1   230/400V 3W+N+PE, 50/60Hz; 32A IEC 60309 32A   230V, 50/60Hz; <= 96A   6xC19 <=16A each, 18xC13 <=10A each IEC 60320 C13 & C19 /L1a, L1b, L2a, L2b, L3a, L3b <= 16A /L1, L2, L3 <=32A
CS-24H52484A1 CL-24H52484A1 240/416V 3W+N+PE, 50/60Hz; 16A   NEMA L22-20P 240V, 50/60Hz; <= 48A   6xC19 <=16A each, 18xC13 <=12A each   IEC 60320 C13 & C19 L1a, L1b, L2a, L2b, L3a, L3b <= 20A L1, L2, L3 <=16A/
CS-24H53484A1 CL-24H53484A1 240/416V 3W+N+PE, 50/60Hz; 16A   IEC 60309 16A 240V, 50/60Hz; <= 48A   6xC19 <=16A each, 18xC13 <=12A each   IEC 60320 C13 & C19 L1a, L1b, L2a, L2b, L3a, L3b <= 20A L1, L2, L3 <=16A/
CS-24H54484A1 CL-24H54484A1 240/416V 3W+N+PE, 50/60Hz; 24A   IEC 60309 24A 240V, 50/60Hz; <= 72A   6xC19 <=16A each, 18xC13 <=12A each   IEC 60320 C13 & C19 L1a, L1b, L2a, L2b, L3a, L3b <= 20A L1, L2, L3 <=24A/
CS-24H5Z484A1 CL-24H5Z484A1 240/416V 3W+N+PE, 50/60Hz; 24A   NEMA L22-30P 240V, 50/60Hz; <= 72A   6xC19 <=16A each, 18xC13 <=12A each   IEC 60320 C13 & C19 L1a, L1b, L2a, L2b, L3a, L3b <= 20A L1, L2, L3 <=24A/



  Additional Features and Specifications

Standards
> cTUVus - UL 60950-1-2003 >
> CAN/CSA 22.2 No. 60950-1:2003
> FCC Class A, Part 15
> EMC-EN 55022 Class A, EN 55024

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPv3/LDAPS
> TACACS+
> RADIUS
> RS-232 (Serial)

Branch Circuit Protection

> Compliant to UL 60905-1

Accessories 
> EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m)
> EMCU-1-1B allows up to (2) additional temperature & humidity probes, (1) water sensor, (4) dry contact closures, (1) analog-to-digital contact sensor. Includes (1) temperature/humidity probe with unit.
> Sentry Power Manager (SPM)

 




Call Us: 1-978-452-2299
First Name:
Last Name:
Company:
Address:
Mail Stop:
City:
State (if in US):
Province/Region (if outside US):
Country:
ZIP (Postal) Code:
E-mail:
Telephone:
Fax:
Questions/Comments:
Verification:

View Full Site View Mobile Optimized