Bomara Home » Server Technology » Smart IP PDU » Smart CS-36VD/VY: 20/30A 3 phase Busway 24xC13 & 12xC19 with PIPS

 Smart CS-36VD/VY: 20/30A 3 phase Busway 24xC13 & 12xC19 with PIPS
  3-Phase PIPS, Per Inlet Power Sensing, power distribution, 36 mixed outlets in 1U vertical CDU


CS-36VDD458A4_Master



  • Description
  • Specifications
  • Gallery

This three phase Sentry PIPS CDU combines all of the features of a Smart CDU with the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy. This information replaces branch circuit monitoring devices typically installed in the power distribution panel or remote power panel (RPP) with higher accuracy and lower cost monitoring of each circuit attached to the CDU.

Combine the Sentry PIPS Smart Cabinet PDU with the Sentry Power Manager (SPM) software tool to gain power usage information across multiple Cabinet PDU's individual IP address.

This Smart cabinet PDU delivers reliable power distribution, local power monitoring via LEDs, power monitoring via IP and environmental (temperature & humidity) monitoring via IP.   

Increasing power demands and density in the equipment cabinet requires new functionality from your cabinet PDU.  The Sentry cabinet PDU product family uniquely meets these demands. 

The Sentry Cabinet Power Distribution Unit (cabinet PDU) is an intelligent PDU with local LED input current monitoring, allowing network engineers to utilize the cabinet PDU's True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new equipment units are added to the power drop, immediately observe its impact on the cumulative current draw. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit.   

The cabinet PDU meets new UL 60950-1 Branch Circuit Protection requirements.   




Remote Power Monitoring

Monitor input power via IP or serial interface.

HTTP/HTTPs Web Configuration & Control

Use the Sentry Web interface to configure each unit's network settings. SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.

SNMP Management & Event Notification

The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information such as input power, temperature and humidity. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, and closed contacts (cabinet doors open/close).

Add a Second Tower

Connect an Expansion Cabinet PDU to this Smart Cabinet PDU to control two power input circuits and monitor power in the Data Center cabinet (individual or groups) under 1 IP address - our exclusive strategy for managing dual power-supply servers.

Zero U Enclosure

A vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet.

Secure Access - SSH or SSL Protection

Secure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device.  Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers.  Sentry supports SSLv3/TLSv1.

Integrated Temp/Humidity Probe Support

Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.

Firmware Flash Upgradable

Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.

LDAP/LDAPS

The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be individually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on individual Sentry products.
Sentry LDAP support has been tested in the following environments:
  - Microsoft Active Directory (MSAD)
  - Novell eDirectory (eDir)
  - Open LDAP

RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.


Sentry  CDU Specifications
Item # Available Input
Voltages
Rated Amperage Available Input Cord** Outlets Dimensions
(L x W x D)
PIPS CS-36VD/VY-3Phase
CS-36VDD458A4
CL-36VDD458A4*
240V, 3-Phase Delta, 50/60 Hz  20A NEMA L15-20P Plug, 10'(3m), Top Cord Entry (24) IEC 60320/C13
(12) IEC 60320/C19
73.5 x 1.75 x 3.50 in.
(1867 x 44 x 89 mm)
CS-36VDE458A4
CL-36VDE458A4*
240V, 3-Phase Delta, 50/60 Hz  30A NEMA L15-30P Plug, 10'(3m), Top Cord Entry (24) IEC 60320/C13
(12) IEC 60320/C19
73.5 x 1.75 x 3.50 in.
(1867 x 44 x 89 mm)
CS-36VYL458A4
CL-36VYL458A4*
208V, 3-Phase Wye, 50/60 Hz  20A NEMA L21-20P Plug, 10'(3m), Top Cord Entry (24) IEC 60320/C13
(12) IEC 60320/C19
73.5 x 1.75 x 3.50 in.
(1867 x 44 x 89 mm)
CS-36VYM458A4
CL-36VYM458A4*
208V, 3-Phase Wye, 50/60 Hz  30A NEMA L21-30P Plug, 10'(3m), Top Cord Entry (24) IEC 60320/C13
(12) IEC 60320/C19
73.5 x 1.75 x 3.50 in.
(1867 x 44 x 89 mm)
**Click here to view additional information on Power Cords and Cables

 

Additional Ordering Information


Part Number Input Output
Master Expansion Rating, North America Input Type Output Rating North America Outlet: North America Outlet Type Branch Circuit: North America Phase: North America
CS-36VDD458A4 CL-36VDD458A4 230V 3W+PE, 50/60Hz; 16A NEMA L15-20P 240V, 50/60Hz; <=27.7A 12xC19 <= 9.2A each, 24xC13 <= 9.2A each IEC 60320 C13/C19 XY, YZ, ZX <= 9.2A XY, YZ, ZX <= 9.2A
CS-36VDE458A4 CL-36VDE458A4 230V 3W+PE, 50/60Hz; 24A NEMA L15-30P 240V, 50/60Hz; <=41.6A 12xC19 <= 13.9A each, 24xC13 <= 12A each IEC 60320 C13/C19 XY, YZ, ZX <= 13.9A XY, YZ, ZX <= 13.9A
CS-36VYL458A4 CL-36VYL458A4 120/208V 3W+N+PE, 50/60Hz; 16A NEMA L21-20P 208V, 50/60Hz; <=27.7A 12xC19 <= 9.2A each, 24xC13 <= 9.2A each IEC 60320 C13/C19 XY, YZ, ZX <= 9.2A XY, YZ, ZX <= 9.2A
CS-36VYM458A4 CL-36VYM458A4 120/208V 3W+N+PE, 50/60Hz; 24A NEMA L21-30P 208V, 50/60Hz; <=41.6A 12xC19 <= 13.9A each, 24xC13 <= 12A each IEC 60320 C13/C19 XY, YZ, ZX <= 13.9A XY, YZ, ZX <= 13.9A


Part Number Description
CS-36VDE455A4 Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 208V 3-phase Delta, 30A, NEMA L15-30P Plug, 10 ft (3 m) Cord, Top/front Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers
CS-36VYM455A4 Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 208V 3-phase Wye, 30A, NEMA L21-30P Plug, 10 ft (3 m) Cord, Top/Front Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers
CL-36VDE455A4 Smart CDU (Expansion Unit), PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 208V 3-phase Delta, 30A, NEMA L15-30P Plug, 10 ft (3 m) Cord, Top/front Cord Entry, Middle Display/Network, Circuit Breakers
CL-36VYM455A4 Smart CDU (Expansion Unit), PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 208V 3-phase Wye, 30A, NEMA L21-30P Plug, 10 ft (3 m) Cord, Top/Front Cord Entry, Middle Display/Network, Circuit Breakers


  Additional Features and Specifications

Standards
> cTUVus - UL 60950-1-2003
> CAN/CSA 22.2 No. 60950-1:2003
> FCC Class A, Part 15
> EMC-EN 55022 Class A, EN 55024, CISPR 22 Class A

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPv3 and LDAPS
> TACACS+
> RADIUS
> RS-232 (Serial)

Branch Circuit Protection
> Compliant to UL 60950-1

Accessories
> Temperature & Humidity Probe 
    - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m)
    - EMCU-1-1B add 2 additional Temperature & Humidity ports, 4 contact-closure monitoring ports and 
      1 water sensor port

 